background image

Installation and 

Operation Manual

MPC-HSS

Replacement Single Power Supply Module

Operation 

Manual

Rev. 06/03

Ph:800-421-6511

www.picomacom.com

Summary of Contents for MPC-HSS

Page 1: ...Installation and Operation Manual MPC HSS Replacement Single Power Supply Module Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com ...

Page 2: ...r a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat register This video p...

Page 3: ...has been exposed to rain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has ...

Page 4: ...ive year limited warranty Replacement Single Power Supply Module MPC HSS N 1 redundancy ensures the power supply is configured for dual supply operation which allows for hot insertion or removal of the power supply modules without powering down the system High efficiency 75 redundant power supplies guarantees zero down time Home run DC cables allow removal of individual modules without disabling t...

Page 5: ... 1 Minimum Load 10 of full rated load Operating Temperature 0 to 60 C Storage Temperature 40 to 85 C Overcurrent Protection No damage to outputs when shorted to ground Power Supply Ordering Information Replacement Single Power Supply Module Input IEC 320 Power Inlet on back plane Output Connector 6X JST B12B XH A or Eq on back plane each connector 12 PIN V 4 PIN V 1 5 9 5 1 5 2 6 10 12 2 12 3 7 11...

Page 6: ...inated MODULE REPLACEMENT 1 Remove by sliding module out of the front of chassis 2 Insert replacement by Aligning the top and bottom edge of module with the guide channel in chassis 3 Slide module into chassis until firmly seated and front LED has illuminated OPERATION CARE Dos Don ts Always operate in a cool well ventilated environment Always provide a stable conditioned power source Heed all saf...

Page 7: ...for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully pack the loaner unit and affix the new RMA n...

Page 8: ...MPC HSS 8 Rev 06 03 Ph 800 421 6511 www picomacom com This page left blank intentionally ...