background image

User Guide

Una

Summary of Contents for Una CIC/MC

Page 1: ...User Guide Una...

Page 2: ...he battery 8 Inserting Una in your ear 12 Removing Una from your ear 14 Operation 16 Switching ON OFF 16 Controlling the volume optional 18 Selecting a hearing program 19 Telecoil optional 20 EasyPhon...

Page 3: ...3 Service and Warranty 29 Compliance information 31 Information and description of symbols 32...

Page 4: ...HS Una FS Una FS P The following table shows what battery you need for your hearing aid model Model Zinc air battery size IEC ANSI marking on package code code CIC MC 10 yellow PR70 7005ZD ITC HS 312...

Page 5: ...digital hearing technology currently available on the market Please read these user instructions thoroughly in order to benefit from all the possibilities your new hearing aid has to offer With prope...

Page 6: ...6 Description Una CIC MC Standard Battery size 10 Una ITC HS Standard Battery size 312...

Page 7: ...ry size 13 Protected Microphone Input 2 on models with AudioZoom technology Battery compartment with ON OFF Program switch optional Volume control optional with ON OFF Receiver Sound outlet Custom mad...

Page 8: ...8 Preparation Replacing the battery 1 Remove the protective foil from the new battery 2 Hold the hearing system with the battery compartment upwards and open the battery cover...

Page 9: ...9 3 Remove the old battery 4 Insert the new battery Please ensure that the sign on the battery flat side is on the same side as the sign on the battery cover...

Page 10: ...10 Preparation 5 Gently shut the battery cover until you feel it click into place...

Page 11: ...upside down When your hearing system is not in use leave the battery compartments open to allow any moisture to evaporate We recommend to only use batteries which your hearing care professional approv...

Page 12: ...ssional may have activated a delayed start up timer This function delays the activation of the hearing system for 9 or 15 seconds after the battery door was closed Before insertion please ensure that...

Page 13: ...m between your thumb and index finger using the hand on the same side you wear your hearing system Insert it canal end first into the ear canal Tug gently on your ear lobe and push the hearing system...

Page 14: ...om your ear If possible select the mute mode see page 15 before removing your Una to avoid whistling Una with removal handle Grasp the handle between your thumb and index finger and pull the hearing s...

Page 15: ...humb behind your lobe just below the hard cartilage and gently press your ear upward to push the hearing system out of the canal In order to help it along make chewing movements with your jaw Grasp th...

Page 16: ...6 Operation Switching ON OFF without volume control Switching ON The hearing system is switched ON when the battery cover is closed Switching OFF To switch the hearing system OFF open the battery cove...

Page 17: ...n order to avoid any disturbance when placing it in your ear The activation is confirmed by an acoustic signal Note The mute mode may be used as a temporary OFF function allowing you to switch your he...

Page 18: ...me optional and switching ON OFF with volume control left right up up down down Increase volume Turn the volume control forwards Reduce volume Turn the volume control backwards Note A single beep indi...

Page 19: ...ght ears until a click is felt Wait for about two seconds until the instrument powers up then set the volume as desired Switching OFF Turn the volume control backwards until a click is felt Program sw...

Page 20: ...fessional to print out the complete description of your individual hearing programs and how to access them with your program switch Telecoil T coil optional Your hearing care professional may have act...

Page 21: ...close to your ear An acoustic signal confirms the switching It automatically returns to the previous hearing program when the telephone handset is removed from your ear Some telephones produce a magne...

Page 22: ...e magnet near to the listening end of your telephone handset and release it The magnet will automatically flip to the correct side at the right location Use the double sided adhesive tape to stick the...

Page 23: ...is swallowed please seek the advice of a medical practitioner The magnet used to strengthen the magnetic field of your phone may affect some medical devices or electronic systems Always keep the magn...

Page 24: ...contributes to outstanding performance and a long service life Please use the following specifications as a guideline General information Before using hair spray or applying cosmetics you should remov...

Page 25: ...r soap etc to clean your hearing aids If your hearing aid is performing weakly or fails to operate clean or replace the wax guard system If your hearing aid fails to operate after you have correctly c...

Page 26: ...pletely protects your hearing aid from wax and moisture Cerustop wax guards are also commonly used as an alternative protection system Your hearing care professional will provide you with detailed inf...

Page 27: ...ent change the battery If the problem persists contact your hearing care professional Battery discharges too quickly Insert a new battery and make note of exactly how long it lasts Contact your hearin...

Page 28: ...nd firmly fitted If this is the case but the problem persists please consult with your hearing care professional Pain or inflammation in your ear Remove the hearing aid and consult with your hearing c...

Page 29: ...as batteries tubes earmolds external receivers The warranty only comes into force if a proof of purchase is shown The international warranty does not affect any legal rights that you might have under...

Page 30: ...30 Authorized hearing care professional stamp signature Service and warranty Serial number right Serial number left Date of purchase...

Page 31: ...nts of the Medical Devices Directive 93 42 EEC The full text of the Declaration of Conformity can be obtained from the manufacturer or the local Phonak representative whose address can be taken from t...

Page 32: ...ive 93 42 EEC The numbers after the CE symbol correspond to the code of certified institutions that were consulted under the above mentioned directives This symbol indicates that the products describe...

Page 33: ...n in these user guides This symbol indicates that it is important for the user to pay attention to the relevant warning notices in these user guides Important information for handling and product safe...

Page 34: ...to 1500 hPa The symbol with the crossed out garbage bin is to make you aware that this hearing aid may not be thrown away as normal household waste Please dispose of old or unused hearing aids at wast...

Page 35: ......

Page 36: ...13 05 A W FO Printed in Switzerland Phonak AG All rights reserved Manufacturer Phonak AG Laubisr tistrasse 28 CH 8712 St fa Switzerland EU Representative Phonak GmbH D 70736 Fellbach Oeffingen Germany...

Reviews: