PRODUCT INFORMATION

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down at this moment.

TECHNICAL INFORMATION

-  Voltage 

:  220 - 240 V

-  Frequency 

:  50 - 60 Hz

- Power consumption 

: 1450 W

-  Standby power consumption  : 

 1 W

-  Contents reservoir 

:  755 cc

- Colour setting 

: Black

- SAP coding 

: HD7810/60/C

CONTROL

PCB

L

N

Boiler

Pump M

Push buttons

TCO

Fuse

Fuse

Temp.
Sensor

Water level
Sensor

Summary of Contents for SENSEO HD 7810

Page 1: ... interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption 1450 W Standby power consumption 1 W Contents reservoir 755 cc Colour setting Black SAP coding HD7810 60 C CONTROL PCB L N Boiler Pump M P...

Page 2: ...mber lid cover handle as follows Place the screwdriver on the positions see picture 1 and lift the cover over the snap locks on both positions The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod see picture 2 to each other so that the two pins will get out of the hinge position on the ...

Page 3: ...cup button pump time will be lengthen with 0 5 sec is approximately 3 5 cc mL more coffee When the volume has to increase with 10 cc for example push the 2 cup button 3 times The new value will be stored when you switch the appliance off by pushing the main switch LED will turn off 11 Turn appliance on again and brew one cup measure the volume In case the volume is not within specification repeat ...

Page 4: ...980 4222 247 35870 4222 247 05180 4222 247 39890 4222 247 05110 4213 247 05250 4222 240 06400 4222 259 34887 4222 259 37240 Brewchamber assy complete Black Pad holder single Black Pad holder double Black Foam chamber cover Black Foam chamber Drip tray cover Drip tray Brewchamber Lid Black Lever Black Push Rod Brew chamber radial seal Distrubutor assy 3 Way valve assy Boiler assy TCO V7 0 230 V Pre...

Page 5: ...HD7810 60 C 5 6 EXPLODEDVIEW 1 11 8 10 9 28 12 3 5 2 4 6 7 A ...

Page 6: ...HD7810 60 C 6 6 EXPLODEDVIEW A 20 21 22 23 24 25 26 30 27 13 14 15 29 19 18 ...