background image

IMPORTANT: 

FOR  YOUR  PROTECTION,  YOU  MUST  CAREFULLY  READ  ALL  WARNINGS  AND  INSTRUCTIONS  IN  THEIR  ENTIRETY  PRIOR  TO                 

INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY AND PROPERTY DAM-
AGE. If you do not understand these warnings and instruc ons, or if addi onal informa on  is  desired,  please  contact  Philips  at                 

[email protected]

  

phone 800-227-0758. 



Installa on, service and maintenance of luminaires must be performed by a quali

fi

ed professional and in accordance with all federal, state and local 

laws, regula ons and electrical codes. This professional should be familiar with the construc on and opera on of this product and any hazards in-
volved.  If not quali

fi

ed, do not a empt installa on, service or maintenance. 



To reduce the risk of death, personal injury or property damage from 

fi

re, electric shock, falling parts, cuts, abrasions and other hazards, please read all 

warnings and instruc ons included with the luminaire, on the luminaire’s packaging and a

xed to the luminaire itself. 



Maintenance of the luminaires should be performed by person(s) familiar with the luminaire’s construc on and opera on and any hazards involved.  

 

 

CAUTION 

 RISK OF PRODUCT DAMAGE 



Never connect luminaires and/or components under load with supply voltage turned on. 



Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insula on. 



Do not restrict 

fi

xture ven la on. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insula on, foam or other material that 

will prevent convec on or conduc on cooling. 



Do not exceed luminaire maximum ambient temperature. 



Do not modify the luminaire. 



Only use luminaire in its intended applica on and loca on. 



Led products are polarity sensi ve. Ensure proper polarity before installa on. 



Electrosta c Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installa on and servicing of the luminaire. 



Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance. 



Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and con-
tact [email protected]

 

phone 800-227-0758. 



Always read the luminaires complete installa on instruc ons prior to installa on for any addi onal luminaire speci

fi

c warnings.

 

 



In the case of HID or Fluorescent luminaires, regular re-lamping is required to keep luminaire opera ng within safe limits 



Do not install damaged product.

  Handling and installing damaged products can poten ally increase the risks men oned  In case of damage and/or miss-

ing parts upon arrival of the luminaire, please contact [email protected]

 

phone 800-227-0758. 



These instruc ons do not purport to cover all details or varia ons in equipment nor to provide every possible con ngency to meet in connec on with instal-
la on, opera on or maintenance. Should further informa on be desired or should par cular problems arise which are not covered su

ciently for the pur-

chaser’s or owner’s purposes, this ma er should be referred to [email protected]

 

phone 800-227-0758.

 



Please see luminaire speci

fi

c Installa on and Maintenance Instruc on for addi onal warnings or any applicable FCC or regulatory statements. Failure to 

follow any of these Instruc ons could void luminaires warran es.

 

Luminaire Maintenance 



Regular luminaire maintenance programs are recommended. 



It is recommended to clean the outside of the luminaire and the refractor/lens.  



Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.  



If clean water is not su

cient for cleaning, use a neutral, synthe c, not-scratching and not-abrasive cleaning substance.  



Never use alkaline and/or acetous cleaning substances.  



Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.  



Philips recommends using a cleaning solu on that has a PH between 5 and 8. 



Recycle: For informa on on how to recycle electronic products and components, please visit www.epa.gov.

 

INSTALLATION INSTRUCTIONS                                    PUREFORM BOLLARD (PBL)  

WARNINGS AND INSTRUCTIONS FOR LUMINAIRES 

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY  



Disconnect or turn o

 power before a emp ng any installa on, 

service  or maintenance. 



Verify that supply voltage is correct by referencing the luminaire 
label informa on. 



Make all electrical and ground connec ons in accordance with 
the Na onal Electrical Code (NEC) and any other applicable laws, 
regula ons or codes. 



All wiring connec ons should be capped with UL-approved wire 
connectors. 

WARNING 

RISK OF FIRE OR PERSONAL INJURY 



Keep combus ble materials away from LED/lamp & lens 



Do not operate in close proximity to persons, combus ble       
materials or substances a

ected by heat or drying. 

WARNING

 

RISK OF PERSONAL INJURY 



Wear gloves and safety glasses at all  mes when removing luminaire from 
carton, installing, servicing or performing maintenance.   



Avoid direct eye exposure to the light source while it is on. 

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

 



Allow Led/lamp & lens to cool before handling.  



Do not touch enclosure or light source 



Do not exceed maximum wa age marked on luminaire label. 



Follow all manufacturer’s warnings, recommenda ons, instruc ons and 
restric ons for driver type, burning posi on, moun ng loca ons and    
replacement. 

© 2018 Philips Lighting Holding B.V.  All rights reserved. 
www.philips.com/luminaires 

P/N 443560819190 Rev A 
Page 1 of 4 

Summary of Contents for PureForm

Page 1: ...ge and or miss ing parts upon arrival of the luminaire please contact SanMarcos TSC philips co phone 800 227 0758 These instruc ons do not purport to cover all details or varia ons in equipment nor to provide every possible con ngency to meet in connec on with instal la on opera on or maintenance Should further informa on be desired or should par cular problems arise which are not covered sufficient...

Page 2: ...QUE 4 MAKE ELECTRICAL CONNECTIONS FIXTURE LINE BLACK TO SUPPLY LINE FIXTURE COMMON WHITE TO SUPPLY COMMON AND GROUND GREEN TO GROUND 5 PLACE SPLICES AND EXCESS WIRE IN BOLLARD SHAFT BE SURE TO NOT PINCH WIRES CAREFUL LY SET BOLLARD UPRIGHT ON ANCHOR BASE 6 ALIGN SCREW HOLES ON SHAFT WITH ANCHOR BASE AND SCREW IN THE FOUR 5 16 18 X 3 4 HEX HEAD SCREWS THAT WERE REMOVED IN STEP 2 TIGHTEN TO 10 FT LB...

Page 3: ... SURE NOT TO PINCH ANY WIRES 4 ALIGN SCREW HOLES ON YOKE GAS KET AND SHAFT TIGHTEN THE TWO 1 4 20x5 8 HEX HEAD SCREWS THAT WERE REMOVED IN STEP 1 TO 10 FT LBS 5 ONCE LUMIANIRE IS POWERED ON EN SURE THAT TEST INDICATOR LIGHT TURNS ON FOR A SHORT TIME TEST 30 SEC LET THE UNIT CHARGE FOR AT LEAST AN HOUR BEFORE PRESSING EMERGENCY BUTTON TO ENSURE BOLLARD CAN SWITCH OVER TO EMERGENCY BATTERY POWER EME...

Page 4: ...Philips Lighting Canada Ltd Corporation 281 Hillmount Road 200 Franklin Square Drive Markham ON Canada L6C 2S3 Somerset NJ 08873 USA 2018 Philips Lighting Holding B V All rights reserved www philips com luminaires P N 443560819190 Rev A Page 4 of 4 ANCHOR BASE TEMPLATE 1 1 SCALE ...