A) Electrical service to unit has 

     been interrupted.
B) Timer is defective.
C) Power failure occurred.

A) Assure permanent electrical service 

    (check fuse, plug, pull chain or switch)

 

B) Replace timer motor.
C) Reset time of day

A) By-pass valve is open.
B) No salt in brine tank.

C) Injectors or screen plugged.
D) Insufficient water flowing into

     brine tank.
E) Hot water tank hardness.

F) Leak at distributor tube.

G) Internal valve leak.
H) Reserve capacity has been 

     exceeded.
I)  Program wheel is not rotating with 

    meter output.

J) Meter is not measuring flow.

A) Close by-pass valve.
B) Add salt to brine tank and maintain 

    salt level above water level.
C) Replace injectors and screen.
D) Check brine tank fill time and clean

     brine line flow control if plugged.
E) Repeated flushings of the hot water 

     tank is required.
F) Make sure distributor tube is not cracked. 

     Check O-ring and tube pilot.
G) Replace seals and spacers and/or piston.
H) Check salt dosage requirements and reset 

     program wheel to provide additional reserve.
I) Pull cable out of meter cover and rotate manually.

   Program wheel must move without binding and 

   clutch must give positive “clicks” when program 

   wheel strikes regeneration stop. If it does not, 

   replace timer valve head.
J) Check output by observing rotation of small gear 

    on front of timer with water running in house (Note: 

    program wheel must NOT be against regeneration 

    stop (0) for this check.) Each tooth to tooth is 

    approximately 30 gals. If not performing properly, 

    replace meter cover (dome).

A) Improper salt setting.
B) Excess water in brine tank.

A) Check salt usage and salt setting.
B) See problem #7

Ponds & Water Features • Swimming Pools & Spas • Well Water Sytems • Water Treatment • Wastewater • Rainwater Harvesting

Fleck Model 5600 & 5600 Econominder

Trouble-Shooting Guide

PROBLEM  

CAUSE  

   CORRECTION

Softener fails to 

regenerate 

Softener delivers

hard water

Unit uses too

much salt 

Loss of Water

Pressure 

3

A) Iron buildup in line to water

     conditioner
B) Iron buildup in water conditioner

C) Inlet of control plugged due to foreign

     material broken loose from pipes by 

     recent work done on plumbing 

     system.

A) Clean line to water conditioner

B) Clean control and add resin cleaner to resin bed. 

     Increase frequency of regeneration.
C) Remove piston and clean control.

4

2

1