Page 1: ...1 2018 03 14 146 9020 4 2019 05 16 ENG DS LEDIF Series For Samsung IF015H IF020H IF025H Actual configuration may vary ...

Page 2: ...ke sure the supporting surface will support the combined load of the equipment and hardware Screws must be tightly secured Do not overtighten screws or damage can occur and product may fail Never exceed the Maximum Load Capacity Always use an assistant or mechanical lifting equipment to safely lift and position equipment This product is intended for indoor use only Use of this product outdoors cou...

Page 3: ...3 2018 03 14 146 9020 4 2019 05 16 This page intentionally left blank ENG ...

Page 4: ...m socket screw I 14 x 2 5 wood screw J M5 square nut spare K 3mm allen wrench two tip T handle L wall plate shim M connector plate N M5 x 5mm set screw O bottom vertical spacer Parts Before beginning make sure you have all parts shown below ENG A B C left column right column inside vertical column D E top horizontal assembly bottom horizontal assembly Refer to parts list included for your specific...

Page 5: ... 4 2019 05 16 N I H J M5 x 5mm set screw 14 x 2 5 wood screw M5 x 8mm M5 square nut O L F G bottom vertical spacer wall plate shim top vertical spacer horizontal spacer M connector plate K 3mm allen wrench two tip T handle ...

Page 6: ...6 2018 03 14 146 9020 4 2019 05 16 1 Refer to layout drawing included for your specific model ENG ...

Page 7: ...05 16 2 1 Optional If connecting two top horizontal extrusions first remove inner hook on brackets ENG Remove and save hardware ENG M5 x 16mm D D 2 2 Use extrusion connectors to connect top horizontal extrusions ENG M 4 N 8 D K K D ...

Page 8: ... 2 4 Optional If connecting two bottom horizontal extrusions first remove inner hook on brackets ENG Remove and save hardware ENG E E 2 3 Replace one hook on bracket in between connected extrusions ENG Use saved hardware ENG D H 2 D K K ...

Page 9: ... 14 146 9020 4 2019 05 16 H 2 5 Use extrusion connectors to connect bottom horizontal extrusions ENG N 6 M 3 E E E E 2 6 Replace one hook on bracket in between connected extrusions ENG Use saved hardware ENG K K ...

Page 10: ...ood verify that the wood studs are a minimum of 2 x 4 nominal size and plywood is a minimum Grade BC 1 2 13 mm thick Plywood may be covered by gypsum board drywall up to 5 8 thick WARNING D Level top horizontal extrusion and mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG 2 24 57mm display tile ...

Page 11: ...11 2018 03 14 146 9020 4 2019 05 16 Use a laser level to keep mounting holes level ENG 3 2 ...

Page 12: ...4 2019 05 16 3 3 Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG 5 32 4mm 2 5 64mm 5 32 4mm 3 4 Level extrusion Install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG D I 6 ...

Page 13: ...13 2018 03 14 146 9020 4 2019 05 16 3 5 Secure vertical spacers to the wall flush with the horizontal extrusion ENG 3 8 10mm Edges must be flush ENG I F F F D ...

Page 14: ...20 4 2019 05 16 3 6 Use third vertical spacer to align bottom horizontal extrusion flush with vertical spacer then mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG E F Edges must be flush ENG F E ...

Page 15: ...er to align bottom horizontal extrusion flush with vertical spacer then install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG 3 7 Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG 5 32 4mm 2 5 64mm 5 32 4mm E I 6 ...

Page 16: ...16 2018 03 14 146 9020 4 2019 05 16 4 Refer to layout drawing included for your specific model ENG 5 4 1 ...

Page 17: ...17 2018 03 14 146 9020 4 2019 05 16 4 1 For larger configurations only Secure vertical spacer to the wall flush with the horizontal extrusion ENG 3 8 10mm Edges must be flush ENG I I 2 O E O O E ...

Page 18: ...20 4 2019 05 16 4 2 Use third vertical spacer to align bottom horizontal extrusion flush with vertical spacer then mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG Edges must be flush ENG O E E O ...

Page 19: ...cer to align bottom horizontal extrusion flush with vertical spacer then install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG 4 3 Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG 5 32 4mm 2 5 64mm 5 32 4mm I 6 ...

Page 20: ...20 2018 03 14 146 9020 4 2019 05 16 5 Remove vertical spacers ENG 3 8 10mm F 2 O 2 ...

Page 21: ...21 2018 03 14 146 9020 4 2019 05 16 6 A B Loosen adjust tighten ENG K 1 2 3 C ...

Page 22: ...22 2018 03 14 146 9020 4 2019 05 16 7 1 Hook on and secure outer vertical columns L and R markings designate left and right column ENG B A H 8 Tighten hardware ENG K ...

Page 23: ...23 2018 03 14 146 9020 4 2019 05 16 7 2 Hook on and secure all inside vertical columns ENG C 5 H 20 Tighten hardware ENG K ...

Page 24: ...24 2018 03 14 146 9020 4 2019 05 16 8 1 Loosen hardware on vertical columns ENG K ...

Page 25: ...25 2018 03 14 146 9020 4 2019 05 16 8 2 Plumb and level outer columns then tighten hardware Tighten hardware on four corner wall plates ENG Tighten ENG Tighten ENG K ...

Page 26: ... 4 2019 05 16 8 3 Tie a string between top slots on outer columns in order to level the depth of each vertical column ENG Loosen adjust tighten ENG Tighten ENG Loosen ENG Optional leveling for bowed walls ENG Insert ENG L K ...

Page 27: ...4 2019 05 16 8 4 Tie a string between bottom slots on outer columns in order to level the depth of each vertical column ENG Loosen adjust tighten ENG Tighten ENG Loosen ENG Optional leveling for bowed walls ENG Insert ENG L K ...

Page 28: ...28 2018 03 14 146 9020 4 2019 05 16 8 5 With the string still attached level the height of each column ENG Tighten or loosen to adjust height ENG K ...

Page 29: ...29 2018 03 14 146 9020 4 2019 05 16 8 6 Adjust inner columns to fit horizontal spacers Tighten column hardware after spacing Start from the left column ENG G K ...

Page 30: ...30 2018 03 14 146 9020 4 2019 05 16 8 7 Continue adjusting inner columns to fit horizontal spacers until all are level Tighten column hardware after spacing ENG G K ...

Page 31: ...31 2018 03 14 146 9020 4 2019 05 16 8 8 Remove all spacers ENG ...

Page 32: ...4 2019 05 16 9 1 Level L brackets and mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG 9 2 Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG 5 32 4mm 2 5 64mm 5 32 4mm ...

Page 33: ...33 2018 03 14 146 9020 4 2019 05 16 9 3 Level L brackets Install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG I 12 ...

Page 34: ...34 2018 03 14 146 9020 4 2019 05 16 9 4 Tie a string between center slots on outer column in order to level the depth of each vertical column ENG K ...

Page 35: ...35 2018 03 14 146 9020 4 2019 05 16 9 5 Adjust depth then remove string ENG Loosen adjust tighten ENG K ...

Page 36: ...36 2018 03 14 146 9020 4 2019 05 16 10 1 ENG Attach display tighten connecting hardware and run cables one at a time starting from the bottom left 1 2 3 4 5 6 ...

Page 37: ...37 2018 03 14 146 9020 4 2019 05 16 10 2 7 13 8 14 9 15 10 16 11 17 12 18 ...

Page 38: ...38 2018 03 14 146 9020 4 2019 05 16 11 ENG To remove start from the top right 6 5 4 3 2 7 1 ...

Page 39: ...39 2018 03 14 146 9020 4 2019 05 16 This page intentionally left blank ENG ...

Page 40: ...y not apply to you This warranty does not cover damage caused by incorrect selection installation or the failure to follow Peerless AV instructions or warnings when installing using or storing the product This warranty gives specific legal rights and you may also have other rights which vary from state to state To make a warranty claim in North America contact Peerless AV customer care at 1 800 86...