background image

Patriot Power Generator 

 User Manual 

Unit 4.1L

Summary of Contents for 4.1L

Page 1: ...Patriot Power Generator User Manual Unit 4 1L...

Page 2: ...ncidental which might arise out of the use of such information The use of any such information will be entirely at the user s risk C Reminds you that if this manual is presented in any language other...

Page 3: ...CONTENTS 5 ABOUT THE PATRIOT POWER GENERATOR 6 SYMBOLS AND TERMS 7 SAFETY INSTRUCTIONS 8 GETTING STARTED 9 UNIT OVERVIEW 15 TROUBLESHOOTING FAQ 24 TECHNICAL SPECIFICATIONS 26 WARRANTY INFORMATION 3...

Page 4: ...4...

Page 5: ...use indoors Quiet The protected lithium core produces wattage without the loud continuous sanity challenging noises of other generator engines Renewable Powered and replenished by natural resources su...

Page 6: ...nt Terms Thefollowingtermsarehelpfulforyoutoknowandareusedinthisguide Term Definition A Ampere or Amp AC Alternating Current DC Direct Current kW Kilowatt one thousand Watts LED Light Emitting Diode m...

Page 7: ...could occur You may simultaneously connect as many as 2 DC loads and 2 AC loads as desired within the parameters enforced by the limits of the specific input or output To reduce the risk of electrica...

Page 8: ...om your unit be sure to carefully read this user manual Even though your Patriot Power Generator has many advanced built in safety features it is still important to take some time to become familiar w...

Page 9: ...r external battery indicator D AC output row output power is shown in watts E Combined 12V DC outputs row multiplybothnumberstogetpowerinwatts F USB output row multiply both numbers to get power in wa...

Page 10: ...10 Interface Panel 75 F INT 120V 0 W AC 13 3V 0 6 A DC 5 0V 0 0 A USB 13 6V 8 4 A MAIN SW AC OUTPUTS 120V 1500W Max 12V 20A Max 1 2 3 4 5 6 7...

Page 11: ...11 KEY 1 Main Power Button 2 Smart LCD Display 3 AC Outlets 2 4 AC Outlet Switch 5 DC Anderson Outlet 6 DC Cigarette Outlet 7 DC USB Outlets 4...

Page 12: ...12 DC INPUT 12V 15A AC INPUT 100V 240V EXTERNAL PORT DC12V Back Panel 2 3 4 1...

Page 13: ...13 KEY 1 Cooling Fan 2 AC Charging Input 3 DC Charging Input 4 Expandable Battery Port...

Page 14: ...ndmill etc When the unit is charging the LCD display will show the battery gauge going from empty to full a lightning bolt and the voltage and amperage that is going to the battery WARNING WARNING DC...

Page 15: ...on the outlets will work like normal AC wall outlets in your home just plug in the devices you want to run Pleasenote ifmorethan1500wattsisbeingusedtheunitwillshutoff toprotectitself Thisnormal Pleas...

Page 16: ...will automatically configure the amount of power required to charge run the device up to a maximum of 12 cumulative amps across all 4 ports Each individual port has a max output of 3 amps EXPANDABLE...

Page 17: ...it won t charge when I plug it into the wall The generator is designed to work for over 2500 full discharge and charge cycles If it will not charge when using the AC 120V charging cord follow these s...

Page 18: ...mption draw of any AC or DC device To know the life of a device with the generator as a power source divide the capacity of the generator 600W h or 545W h by the power consumption of the device in wat...

Page 19: ...erator while it is charging you may need to wait 30 seconds while the generator recalibrates and is ready to accept a charge again Charging should resume normally This behavior is a safety feature to...

Page 20: ...re in fact using almost twice the energy that you would if you were to disconnect it from the generator 7 I can t connect my solar panel to my Patriot Power Generator If a solar panel was included in...

Page 21: ...so an object that is next to the solar panel may not create a shadow during one time of the day but may produce a shadow for some or all of the rest of the day Solar panels will produce little to no...

Page 22: ...the panel in the form of heat The panels will become warm just like an electric blanket do not use solar panels as heat sources and will drain the battery connected to it possibly damaging it The othe...

Page 23: ...ion the time you plan to use your unit accordingly The LCD display will help you with these calculations To ensure you are able to enjoy the generator s full battery charge after being used charge it...

Page 24: ...r draws going out of the AC 120V output up to 1500 Watts Most space heaters draw more than 1500 Watts at the higher settings Experiment to find the optimal balance between energy conservation and heat...

Page 25: ...all charges possible up to 32A combined from AC and DC inputs If more current is available than the specified limit the generator will not reject the source as a whole If you knowingly attempt to over...

Page 26: ...ge cycles Minimum Charge Time 3 5 Hours Charge Retention 3 Years 20 state of charge Integrated Inverter 120V AC Pure Sine Wave 9600W for 300 ms then 1600W for 5 seconds then 1500W continuous Max DC Ou...

Page 27: ...onnectors with a total 32A using 12V DC 24V DC input Output Ports AC 110V 120V 60Hz two outlets share a combined total power limit of 1500W with 2000W peak for less than 5 milliseconds USB 4 USB outle...

Page 28: ...defect caused willfully or through negligence Damage caused through excessive wear and tear Cosmetic blemishes scratches or dents caused through the course of regular use Damage caused by use of the u...

Page 29: ...chments and accessories unless specifically directed otherwise when obtaining an RMA number The customer will be billed charged for any missing attachments or accessories 4 When returning a unit it mu...

Page 30: ...30 Notes...

Page 31: ...31...

Page 32: ......

Reviews: