background image

1

TNE1544 and TNE1584

T1 Network Extenders Installation Instructions

Document Number TNE1-A2-GN14-20

July 2005

Contents

Software and Firmware License Agreement

.................................................

2

Introduction to the TNE1544 and TNE1584

..................................................

4

Package Contents

.........................................................................................

4

Release Notes

..............................................................................................

4

Powering Up the Network Extender

..............................................................

5

Connecting the T1 Lines

...............................................................................

6

Connecting the Ethernet Lines

.....................................................................

7

LED Indicators

..............................................................................................

8

Web Interface

................................................................................................ 10

Command Line Interface

............................................................................... 14

Resetting the Network Extender to Factory Defaults

.................................... 15

Connector Pin Assignments

......................................................................... 16

Specifications

................................................................................................ 18

EMI Notices

.................................................................................................. 19

ACTA Customer Information

......................................................................... 19

Supplier's Declaration of Conformity

............................................................. 21

Notice to Users of the Canadian Telephone Network

................................... 21

Important Safety Instructions

........................................................................ 22

Product Documentation Online

..................................................................... 23

Summary of Contents for TNE1544

Page 1: ...g Up the Network Extender 5 Connecting the T1 Lines 6 Connecting the Ethernet Lines 7 LED Indicators 8 Web Interface 10 Command Line Interface 14 Resetting the Network Extender to Factory Defaults 15 Connector Pin Assignments 16 Specifications 18 EMI Notices 19 ACTA Customer Information 19 Supplier s Declaration of Conformity 21 Notice to Users of the Canadian Telephone Network 21 Important Safety...

Page 2: ... Licensee acquires no title right or interest in the Software other than the license granted under this Agreement 2 Licensee shall not use the Software in any country other than the country in which the Product was rightfully purchased except upon prior written notice to Paradyne and an agreement in writing to additional terms 3 The Licensee shall not reverse engineer decompile or disassemble the ...

Page 3: ...ion to another 6 IN NO EVENT WILL PARADYNE BE LIABLE TO LICENSEE FOR ANY CONSEQUENTIAL INCIDENTAL PUNITIVE OR SPECIAL DAMAGES INCLUDING ANY LOST PROFITS OR LOST SAVINGS LOSS OF BUSINESS INFORMATION OR BUSINESS INTERRUPTION OR OTHER PECUNIARY LOSS ARISING OUT OF THE USE OR INABILITY TO USE THE SOFTWARE WHETHER BASED ON CONTRACT TORT WARRANTY OR OTHER LEGAL OR EQUITABLE GROUNDS EVEN IF PARADYNE HAS ...

Page 4: ...d to any combination of T1 uplink interface modules micro interface modules and network extenders so long as every connection pairs a provider and a subscriber unit Provider and Subscriber Defaults The following table highlights the differences between provider and subscriber units Package Contents Unpack and Inspect the network extender If there is any visible damage do not attempt to connect the...

Page 5: ...en all screws at the top of the power terminal strip 2 Insert your ground wire in the center terminal and tighten the screw 3 Insert your 48 VDC lead into the negative terminal of a terminal pair Tighten the screw for that terminal 4 Insert your 48 VDC return lead into the positive terminal of the same terminal pair as in Step 3 Tighten the screw for that terminal 5 Repeat Step 3 and Step 4 for th...

Page 6: ...blish loop bonded connections with other Paradyne equipment with the loop bonding feature See Product to Product T1 Loop Bonding Compatibility document number COMP A2 GK43 Procedure 1 Plug the T1 cables into the T1 Connections RJ48C ports on the back of the network extender The order of connection is not important 2 Verify all connections the T1 Connections Lnk Alm LEDs on the front of the network...

Page 7: ... speed and duplex mode in accordance with the remote equipment to which it is connected or Ethernet speed and duplex mode configurations can be configured using NMS See Web Interface on page 10 For the best connection results the remote devices PCs hubs or switches should be set to auto negotiate speed and duplex mode Procedure 1 Plug the Ethernet cable into one of the 10 100 Ethernet ports on the...

Page 8: ...lluminated No Ethernet connection The Ethernet 100 and Act LEDs will remain unlit by default 10 100 Ethernet Connections Duplex Collision Solid Amber Full duplex Ethernet connection Not Illuminated No link or functioning at half duplex Pulsing Amber Half duplex link with packet collisions 10 100 Ethernet Connections 100 Solid Green 100 Mbps Ethernet connection is established If the Ethernet 100 LE...

Page 9: ... its partner network extender Blue alarm The unit s partner network extender has lost a connection with an intermediate device and has LOS or RAI T1 Connections Tx Ports 1 4 or 1 8 Flashing Amber Data is being transmitted Not Illuminated No data is being transmitted T1 Connections Rx Ports 1 4 or 1 8 Flashing Amber Data is being received Not Illuminated No data is being received Power Solid Green ...

Page 10: ... bottom label of the subscriber unit 2 Open a command prompt Click on Start then Run In the Open window type CMD and press Enter At the command line type arp s 192 168 254 251 xx xx xx xx xx xx where the IP address is the default address of the subscriber unit and the MAC address is the number on the bottom label with 1 added to the last byte For example if the MAC address on the bottom label is 0...

Page 11: ... on the Start button and then click on Control Panel 2 Double click on the Network Connections icon 3 In the LAN or High Speed Internet window right click on the icon corresponding to your network interface card NIC and select Properties Often this icon is labeled Local Area Connection The Local Area Connection dialog box is displayed with a list of currently installed network items 4 Ensure that ...

Page 12: ...12 10 Click on Next The login dialog box appears Log in using The NMS home page appears Username superuser Password Password ...

Page 13: ...em Name and Location Management IP Address Filter TFTP and Telnet access HTTP Password General and Superuser Passwords SNMP Config SNMP Notification IP Addresses and SNMP Traps SNMP Community SNMP Community Names Ethernet Connections Lnk Act LEDs Ethernet Duplex Mode and Speed T1 Connections Lnk Alm LEDs T1 Data Rate Frame Type Line Code Tx Buildout and Clock Source ...

Page 14: ... you may need to install a Telnet client Connecting a PC Directly Initial configuration using the CLI requires a direct physical connection from your PC to the COM port of the network extender you are configuring However the web interface is recommended for subsequent configuration Procedure 1 Plug a DB9 to 8 pin modular adapter into the RS232 serial port on your PC See DB9 to 8 Pin Modular Adapte...

Page 15: ...r s Ethernet ports and opening the address 137 182 10 251 in a web browser Resetting the Network Extender to Factory Defaults The network extender supports a reset process that may be used to delete the current configuration and return it to the factory defaults including the default password Procedure To return the network extender to its factory default configuration 1 The reset button is locate...

Page 16: ... RJ48C Pin Assignments Pin Function Pin 1 Rx Ring Pin 2 Rx Tip Pin 3 not used Pin 4 Tx Ring Pin 5 Tx Tip Pin 6 not used Pin 7 not used Pin 8 not used Table 4 Ethernet Pin Assignments Pin Function Pin 1 Rx Pin 2 Rx Pin 3 Tx Pin 4 not used Pin 5 not used Pin 6 Tx Pin 7 not used Pin 8 not used ...

Page 17: ...wn Pins not shown are unused Table 5 DB9 to 8 Pin Modular Adapter Pinouts Pin 8 Pin Modular Port Direction PC RS232 Serial Port Pin 1 Transmit Data TxD RxD Receive Data 2 2 Data Set Ready DSR RTS Request to Send 7 4 Receive Data RxD TxD Transmit Data 3 5 Ground GND GND Ground 5 6 Data Terminal Ready DTR CTS Clear to Send 8 ...

Page 18: ... T1 4 10 100BaseT 8 position jacks Operating Environment Temperature 32 F to 122 F 0 C to 50 C Non operating temperature 40 F to 158 F 40 C to 70 C Humidity 5 to 95 non condensing Altitude 200 ft to 16 500 ft 60 m to 5 000 m Power TNE1544 48 VDC 0 2 A 11 W TNE1584 48 VDC 0 3 A 15 W Protocols Supported Transparent 802 1D Bridging T1 Frame Type ESF SF T1 Line Code B8ZS AMI Regulatory Compliance EMC ...

Page 19: ...gital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada ACTA Customer Information This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal Attachments ACTA On the bottom of the network extender is a label that contains among other information a product identi...

Page 20: ...rrupted service If trouble is experienced with this equipment please contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Paradyn...

Page 21: ... Senior Vice President Chief Financial Officer Notice to Users of the Canadian Telephone Network NOTICE This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry ...

Page 22: ...r more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA c...

Page 23: ...n for Paradyne products is available at www paradyne com Select Support Technical Manuals To order a paper copy of a Paradyne document or to speak with a sales representative please call 1 727 530 2000 Copyright 2005 Paradyne Corporation Printed in U S A ...

Page 24: ...24 TNE1 A2 GN14 20 TNE1 A2 GN14 20 ...

Reviews: