![background image](http://html1.mh-extra.com/html/panasonic/wj-nd400k/wj-nd400k_quick-reference-manual_3869735001.webp)
LCD
[ESC] button
[SET] button
Arrow buttons
Quick Reference Guide
The Quick Reference Guide provides simple explanations of how to operate this recorder.
■
Network settings
Configure the network settings such as the IP address, subnet mask, etc. for each port.
Item
Camera port
[PT#1]
Client PC port
[PT#2]
Maintenance port
[PT#3]
DHCP
_
OFF
_
IP address
192.168.0.250
192.168.1.250
192.168.2.250
Subnet mask
255.255.255.0
255.255.255.0
255.255.255.0
Default gateway
_
192.168.1.1
_
HTTP port
_
80
_
●
Default network settings
Network Disk Recorder
WJ-ND400K, WJ-ND400K/G
●
IP address setup display
●
How to configure the network settings
Repeat pressing the arrow button (up
or down) until the "IP Address Setup"
indication is displayed. When the "IP
Address Setup" indication is displayed,
press the [SET] button.
• The current selected setup item or
a value will be indicated by the
underscore mark "_".
→
The setup window will be displayed.
• When the underscore mark "_" is
below the ">" indication,
Arrow button (left or right): Select a
port number
Arrow button (up or down): Select a
setup item
Press the [SET] button while the under-
score mark (_) is displayed below the ">"
indication.
→
The underscore mark "_" will move
below a setting value and the
editing of the settings became
enabled.
Move the underscore mark below the
number to be edited.
• Arrow button (left or right): Move the
underscore mark "_"
• Arrow button (up or down): Enter a
value
To determine the edited setting, move
the underscore mark below the ">" indi-
cation by pressing the [ESC] button.
To display the time and date display
(standby display) again, press the [ESC]
button again.
■
Display the operation window
Display the operation window using a web browser installed on a PC.
Launch a web browser. After the web
browser starts, enter the IP address set
to this recorder in the address box, and
press the enter key.
→
The user authentication window will
be displayed.
Enter the registered user name and
password to log in to the recorder.
• Default
User name: ADMIN
Password:
12345
Click the [login] button.
→
The top page of the operation window
will be displayed.
• When the top page is displayed for
the first time, the install wizard of the
ActiveX control will be displayed.
Follow the instructions of the wizard.
[SET]