background image

Hybrid IP-PBX

PT Programming Manual

Thank you for purchasing a Panasonic Hybrid IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.

PSMPR Software File Version 4.0000 or later

 Model No.    

KX-TDA15

Summary of Contents for KX-TDA15

Page 1: ...amming Manual Thank you for purchasing a Panasonic Hybrid IP PBX Please read this manual carefully before using this product and save this manual for future use PSMPR Software File Version 4 0000 or l...

Page 2: ...hat the PBX can do as well as how to obtain the most of its many features and facilities Sections from the Feature Guide are listed throughout the PT Programming Manual for your reference Installation...

Page 3: ...er languages may be available depending on the country or area The KX TDA15E KX TDA15NE KX TDA15GR and KX TDA15CE are designed to interwork with the Analogue Public Switched Telephone Network PSTN of...

Page 4: ...ine Access Local Access 24 110 System Password for Administrator for PT Programming 24 111 System Password for User for PT Programming 24 112 Manager Password 24 120 Verification Code 24 121 Verificat...

Page 5: ...418 LCOT Disconnect Time 32 420 BRI Network Type 33 421 BRI DIL DDI MSN Selection 33 422 BRI Subscriber Number 33 424 BRI Layer 1 Active Mode 33 425 BRI Layer 2 Active Mode 33 426 BRI Configuration 3...

Page 6: ...Extension User Groups of a Pickup Group 43 660 VM Group Floating Extension Number 43 680 Idle Extension Hunting Type 43 681 Idle Extension Hunting Group Member 43 690 PS Registration 44 691 PS Termin...

Page 7: ...PT Programming Manual 7 902 Slot Card Reset 49 3 Appendix 51 3 1 Revision History 52 3 1 1 KX TDA15 PSMPR Software File Version 4 0xxx 52 3 2 Feature Programming References 53...

Page 8: ...8 PT Programming Manual...

Page 9: ...PT Programming Manual 9 Section 1 Overview This section provides an overview of programming the PBX...

Page 10: ...programming at a time Any other users trying to enter system programming mode will be denied access Ways to Programme There are two programming methods PC Personal Computer Programming All features a...

Page 11: ...of the passwords and the possible dangers if they become known to others 3 The PBX has default passwords preset For security change these passwords the first time that you programme the PBX 4 Change t...

Page 12: ...Characters The following characters can be used when storing a name message or other text entry data using a PT The tables below show you the characters available by pushing each button a specific nu...

Page 13: ...1 1 Introduction PT Programming Manual 13 Table 2 Option mode for CE model Table 2 Option mode for GR model...

Page 14: ...ss When entering two or more characters that use the same button consecutively e g G and I you must press this button or the FWD DND button after entering the first character If SELECT is pressed the...

Page 15: ...PT Programming Manual 15 Section 2 PT Programming This section serves as reference operating instructions when using a display PT to program the PBX...

Page 16: ...nected to the lowest numbered port on the card installed in the lowest numbered slot Only one system programming session can be performed at a time This means that only one user can access system prog...

Page 17: ...h PC programming Note means default value throughout this manual Programming Structure SELECT FLASH CLEAR SECRET 1 The buttons shown in this column are from the KX T7600 series 2 The buttons shown in...

Page 18: ...5XX COS Programming Class of Service parameters 6XX Extension Programming Extension feature settings 7XX Resource Interface Programming PBX interface and external device settings 8XX SMDR Maintenance...

Page 19: ...Enter values as two digit numbers e g 04 for port 4 Slot Number Supported Cards 01 Pre installed Super Hybrid Ports 02 Pre installed BRI2 card 03 04 BRI1 BRI2 slot 03 only LCOT2 cards 05 06 DLC8 card...

Page 20: ...ND HOLD ENTER ENTER ENTER 01 12 Month NEXT AM PM SELECT AUTO ANS MESSAGE 000 00 99 Year 01 31 Date 00 23 Hour 00 59 Minute END HOLD ENTER ENTER ENTER 01 12 Month NEXT 001 000 999 Speed Dialling No Tel...

Page 21: ...s will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily gu...

Page 22: ...012 Charge Rate per Unit 008 1 8 Location No END Message ENTER ENTER Max 16 characters 010 2 2 decimal places Margin XX YY END ENTER ENTER 011 01 03 Location No 2 2 decimal places Tax XX YY END ENTER...

Page 23: ...n No To the Desired Location No 1 4 digits 101 Manual Automatic END SELECT AUTO ANS MESSAGE ENTER ENTER 102 01 00 12 59 Hour Minute END ENTER ENTER Day No Time No 0 Sun 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6...

Page 24: ...e 122 Verification Code Personal Identification Number PIN 103 Location No Trunk Group No END ENTER ENTER 01 64 01 64 110 4 10 digits Password END ENTER ENTER 1234 111 4 10 digits Password END ENTER E...

Page 25: ...To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed c Changing PINs frequently 123 Verificati...

Page 26: ...matic Redial Repeat Times 206 Automatic Redial Interval 207 Door Unlock Time 200 0 240 s Time END HOLD ENTER ENTER 201 END ENTER ENTER 1 240 s Time 203 END ENTER ENTER 1 240 s Time 1 Day 2 Lunch 3 Bre...

Page 27: ...Time for LCOT 209 DISA Delayed Answer Time 210 DISA Trunk to Trunk Call Prolong Time 211 DISA Intercept Time 208 0 60 s Time END ENTER ENTER 209 0 30 s Time END ENTER ENTER 210 0 7 min Time END ENTER...

Page 28: ...Enable END HOLD SELECT AUTO ANS MESSAGE ENTER ENTER ENTER ENTER 301 2 6 Level No Max 16 digits Denied Code 001 100 Location No END CANCEL NEXT To the Next Location No To the Desired Location No 302 2...

Page 29: ...TER 325 001 200 Location No Max 16 digits Exception No END ENTER ENTER 01 16 Plan Table No 01 12 00 59 Hour Minute 0 Sun 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6 Sat Day No END 1 TimeA 2 TimeB 3 TimeC 4 TimeD...

Page 30: ...arrier Access 353 ARS Carrier Access Code 350 01 10 Carrier Table No Max 20 characters Name END ENTER ENTER SELECT 351 Carrier Table No Trunk Group No END ENTER ENTER 01 10 01 64 SELECT Disable Enable...

Page 31: ...o Connect Connect END HOLD SELECT AUTO ANS MESSAGE CANCEL NEXT To the Next Port No To the Desired Port No Slot No Port No 01 02 02 04 401 Max 20 characters Name END ENTER ENTER 3 digits Trunk No 402 0...

Page 32: ...o 03 04 01 02 413 0 None 1 6 5 2 113 N 1 8 ms END ENTER ENTER Slot No Port No Mode No 03 04 01 02 414 END ENTER ENTER 0 None 1 6 5 2 113 N 1 8 ms Slot No Port No Mode No 03 04 01 02 415 Disable Outgoi...

Page 33: ...tting 426 BRI Configuration Note After changing this setting perform 902 Slot Card Reset to enable the new setting ENTER ENTER 420 Slot No Port No 00 56 Network Type END 02 04 01 02 421 Slot No Port N...

Page 34: ...ix TEI END ENTER Clear for Automatic 02 04 01 02 450 END ENTER ENTER Time No Slot No Port No Destination No 1 Day 2 Lunch 3 Break 4 Night 1 5 digits 02 04 01 02 451 0001 1000 Location No Max 32 digits...

Page 35: ...490 Caller ID Signal Type 472 Trunk Group No 01 60 min Time END ENTER ENTER 01 64 473 Trunk Group No 01 60 min Time END ENTER ENTER 01 64 ENTER ENTER 475 Trunk Group No No Detect Detect END SELECT 01...

Page 36: ...Break 4 Night 01 64 COS No Time No Trunk Group No Disable Enable END HOLD SELECT AUTO ANS MESSAGE ENTER ENTER NEXT To the Next Trunk Group No To the Next COS No Page up 01 64 501 01 64 COS No Time No...

Page 37: ...nsion Dial Lock 511 Manager Assignment SELECT Disable Enable 505 01 64 COS No END ENTER ENTER Disable Enable SELECT ENTER ENTER 506 01 64 COS No END SELECT Disable Enable 507 01 64 COS No END ENTER EN...

Page 38: ...Wireless XDP Parallel Mode for Paired Telephone 516 Programming Mode Limitation Disable Enable SELECT 512 01 64 COS No END ENTER ENTER 514 01 64 COS No END Disable Enable SELECT ENTER ENTER SELECT Dis...

Page 39: ...CT AUTO ANS MESSAGE ENTER ENTER CANCEL NEXT To the Next Port No To the Desired Port No 01 01 04 601 Slot No Port No END SELECT ENTER ENTER Telephone DSS Console 01 04 Voice Mail 1 01 04 PC Console 1 2...

Page 40: ...p Name 606 Max 16 digits 1 5 digits CLIP COLP No END ENTER ENTER Extn No 620 Location No Incoming Call Distribution Group No END ENTER ENTER Extn No 001 128 01 32 1 5 digits 621 Location No END Immedi...

Page 41: ...ng Call Distribution Group No 001 128 625 1 Day 2 Lunch 3 Break 4 Night Max 32 digits Destination No END ENTER ENTER Time No Incoming Call Distribution Group No 001 128 626 1 125 10 s Overflow Time EN...

Page 42: ...ution Group No 001 128 630 1 Day 2 Lunch 3 Break 4 Night Table No Time No END ENTER ENTER Incoming Call Distribution Group No 001 128 01 64 None 631 01 16 Number must be entered in the N Location No T...

Page 43: ...Idle Extension Hunting Group Member 641 External Pager No Paging Group No END SELECT ENTER ENTER No Yes 01 32 1 650 Pickup Group No END SELECT ENTER ENTER No Yes Extn User Group No 01 64 001 032 660 1...

Page 44: ...Number PIN for PS Registration 699 CS Status Reference 690 001 028 PS No KX TCA255 1 4 digits END ENTER ENTER To the PS operation below Extn No Select Setting Handset Select Register H set Select Reg...

Page 45: ...ion 729 Doorphone Number Reference 700 1 Pager No END HOLD ENTER ENTER Extn No 1 5 digits 710 END External Internal1 Internal2 ENTER ENTER SELECT AUTO ANS MESSAGE 711 END Tone BGM Music Source No ENTE...

Page 46: ...ing Message OGM Floating Extension Number 731 Outgoing Message OGM Name 732 DISA Security Mode 730 END Message No ENTER ENTER Extn No 01 32 1 5 digits 731 END Message No Max 20 characters Name ENTER E...

Page 47: ...Length 801 External Modem Control 802 SMDR Page Length 800 END HOLD CR LF CR SELECT AUTO ANS MESSAGE 1 Location ENTER ENTER 800 END 2400 4800 9600 19200 38400 57600 115200 bps 2 Location ENTER ENTER...

Page 48: ...SMDR Incoming Call Printing 810 Remote Programming 812 ISDN Remote Floating Extension Number 803 END 0 95 lines Skip Perforation ENTER ENTER 804 END No print Print SELECT ENTER ENTER 805 END No print...

Page 49: ...Slot Card Deletion 902 Slot Card Reset 900 Reference only 01 11 Slot No Card Name END HOLD ENTER 901 END ENTER Slot No Delete ENTER To the Next Slot No To the Desired Slot No NEXT Confirming the delet...

Page 50: ...2 1 PT Programming 50 PT Programming Manual...

Page 51: ...PT Programming Manual 51 Section 3 Appendix...

Page 52: ...Point Position for Currency 602 Class of Service 603 Extension User Group 604 Extension Intercept Destination 605 Call Forwarding No Answer Time 606 CLIP COLP Number 620 Incoming Call Distribution Gr...

Page 53: ...Routing Plan Time Table 331 346 ARS Routing Plan Table 1 16 350 ARS Carrier Name 351 ARS Trunk Group for Carrier Access 352 ARS Removed Number of Digits for Carrier Access 353 ARS Carrier Access Code...

Page 54: ...Name 490 Caller ID Signal Type Feature Guide Reference 1 16 1 Caller ID Calling Line Identification CLI Distribution 001 System Speed Dialling Number 002 System Speed Dialling Name Feature Guide Refer...

Page 55: ...election 410 LCOT Dialling Mode 411 LCOT Pulse Rate 412 LCOT DTMF Minimum Duration Feature Guide Reference 1 5 4 4 Dial Type Selection Direct In Line DIL 421 BRI DIL DDI MSN Selection 450 DIL 1 1 Dest...

Page 56: ...ure Guide Reference 1 3 1 3 Do Not Disturb DND Door Open 207 Door Unlock Time 512 Permission for Door Open Access Feature Guide Reference 1 15 2 Door Open Doorphone Call 720 Doorphone Call Destination...

Page 57: ...l Feature Access EFA F Flash Recall Terminate 418 LCOT Disconnect Time Feature Guide Reference 1 10 6 Flash Recall Terminate Flexible Numbering Fixed Numbering 100 Flexible Numbering Feature Guide Ref...

Page 58: ...2 1 Idle Extension Hunting Incoming Call Distribution Group Features 620 Incoming Call Distribution Group Member 621 Incoming Call Distribution Group Delayed Ringing 622 Incoming Call Distribution Gro...

Page 59: ...n 006 Operator Assignment Feature Guide Reference 1 1 1 7 Intercept Routing No Destination Intercom Call 003 Extension Number 004 Extension Name Feature Guide Reference 1 5 3 Intercom Call Internal Ca...

Page 60: ...N Network Direct Station Selection NDSS 511 Manager Assignment Feature Guide Reference 1 26 5 1 Network Direct Station Selection NDSS O Operator Features 006 Operator Assignment Feature Guide Referenc...

Page 61: ...of a Paging Group 641 External Pagers of a Paging Group Feature Guide Reference 1 14 1 Paging Parallelled Telephone 600 EXtra Device Port XDP Mode Feature Guide Reference 1 10 9 Parallelled Telephone...

Page 62: ...Incoming Call Distribution Group Distribution Method Feature Guide Reference 1 26 6 1 PS Roaming by Network ICD Group PT Programming 2 1 PT Programming 516 Programming Mode Limitation Feature Guide R...

Page 63: ...Message Detail Recording SMDR 800 RS 232C Parameter New Line Code 800 RS 232C Parameter Baud Rate 800 RS 232C Parameter Word Length 800 RS 232C Parameter Parity Bit 800 RS 232C Parameter Stop Bit Len...

Page 64: ...all Barring Barring Trunk Access 400 LCOT BRI Trunk Connection 401 LCOT BRI Trunk Name 409 LCOT BRI Trunk Number Reference 500 Trunk Group Number Feature Guide Reference 1 5 5 3 Trunk Access Trunk Ans...

Page 65: ...ice Mail VM Group Voice Mail DPT Digital Integration 201 Transfer Recall Time Feature Guide Reference 1 20 3 Voice Mail DPT Digital Integration W Walking COS 005 Extension Personal Identification Numb...

Page 66: ...material is copyrighted by Panasonic Communications Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic...