3 Product Specifications

-----------------------------------------

CONTENTS

Page

Page

6

WAR NING

This serv ice informati on is design ed for experienced repair technicians only a nd is not des igned for us e by the gene ral pu blic.
It d oes no t cont ain warnings or cau tions to advise non-tech ical ind ividua ls of potenti al dangers in attempting t o serv ice a product.
Pro ducts power ed by electricity should b e serviced or repaired only by experie nced profes sional technicians. Any a ttemp t to service
or r epair the pro duct o r products dealt w ith in th is service informa tion by anyon e else could result in serious injury or death.

4 Dimensions

--------------------------------------------------

10

6 Wiring diagram

--------------------------------------------------

13

7 Exploded View

8 Replacement Parts List

9 Exploded View

10 Replacement Parts List

-----------------------------------------

-----------------------------------------

-----------------------------------------

-----------------------------------------

14

15

16

17

2 Functions

3

------------------------------------------------------

1 Features

2

--------------------------------------------------------

Please file and use this manual together with the servic e manual for Mode l No. CS-PE9 DKE CU-PE9DKE CS-PE12DKE

CU-PE12DKE , Order No. GMAC 050 6048C2

5 Block Diagram

------------------------------------------------

12

Summary of Contents for CS/CU-RE9GKE

Page 1: ...echical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to s...

Page 2: ...Timer Setting 4 kinds of Timer mode Zero ozone depleting potential and low global warming potential by using R410A refrigerant Comfort Environment Air filter with function to reduce dust and smoke Bre...

Page 3: ...the ON OFF Timer hourly later Set Cancel Timer Operation Set timer Cancel the set timer 2 Functions Remote Control OFF ON MODE FAN SPEED AIR SWING TEMP TIMER OFF ON TIMER SET CANCEL Turn on off the a...

Page 4: ...oor Fan Speed Control Automatic Airflow Direction Control The louver automatically swings up and down Five Manual Airflow Direction Control Airflow Direction Control Delayed On timer Control For cooli...

Page 5: ...It stops immediately with remote control ON OFF button 4 way Valve Control If the unit is stopped during Heating Operation the 4 way valve will remain in heating mode operation for 3 minutes Total Run...

Page 6: ...kg W W W rpm rpm rpm CS RE9GKE CU RE9GKE 2 60 0 90 3 00 3 30 0 90 4 10 1 5 Single 230 50 Cooling high47 Heating high48 Cooling high42 Low27 Heating high42 Low27 Cooling 750 190 1000 Heating 820 170 11...

Page 7: ...ion Inner Diameter mm c c g mm L min mm F V Evaporator Copper Slot type Plate fin configuration forced draft 2 x 15 1X24 Condenser Copper Corrugation type 20 610x315x25 4 Electronic Control P P Honeyc...

Page 8: ...m rpm CS RE12GKE CU RE12GKE 3 50 0 90 3 90 4 25 0 90 5 10 2 0 Single 230 50 Cooling high48 Heating high50 Cooling high42 Low30 Heating high42 Low33 Cooling 1010 170 1200 Heating 1140 150 1460 Cooling...

Page 9: ...evice Fan Motor Capacitor Unit CS RE12GKE CU RE12GKE Length Circulation Inner Diameter mm c c g mm L min mm F V Evaporator Copper Slot type Plate fin configuration forced draft 2 x 15 2X24 Condenser C...

Page 10: ...Liquid Side Drain Port Air intake Side view 183 Air outlet Left Piping Hole Right Piping Hole 100 16 56 Unit mm Installation plate Front View h r DEL AY h r DEL AY OFF ON SELECT SET CANCEL ER ROR R E...

Page 11: ...Outdoor Unit CU RE9 12GKE 11 Unit mm 10cm or more 10cm or more 100cm or more 48 320 352 INVERTER 780 57 570 Top View 105 CS RE9GKE CU RE9GKE CS RE12GKE CU RE12GKE...

Page 12: ...R Y C RY FM 5 Block Diagram CS RE9GKE CU RE9GKE CS RE12GKE CU RE12GKE 12...

Page 13: ...G TEMP BR R O Y P MOTOR 1 5 MOTOR 1 4 15 ELECTRONIC CONTROLLER MAIN 1 L 2 N 3 WIRELESS REMOTE CONTROL 1 L 2 N 3 W U V B092256 U W V W 1 152 1 152 1 152 TERMINAL FUSE 1 2 S ENS OR PIPING TEMP S ENS OR...

Page 14: ...7 Exploded View 14 1 3 4 2 25 33 32 29 30 31 26 31 30 7 8 11 21 9 10 20 19 24 16 23 13 12 14 17 15 5 6 34 CS RE9GKE CS RE12GKE 37 35 36 CS RE9GKE CU RE9GKE CS RE12GKE CU RE12GKE...

Page 15: ...932689 CWD932689 15 TERMINAL BOARD COMPLETE 1 CWA28C2279 CWA28C2279 16 POWER SUPPLY CORD COMPLETE 1 CWA20C2609 CWA20C2609 17 ELECTRONIC CONTROLLER 1 CWA73C2643 CWA73C2642 19 INDICATOR HOLDER FRONT 1 C...

Page 16: ...9 Exploded View CU RE9GKE CU RE12GKE 16 37 39 6 7 3 4 5 2 34 42 38 34 29 31 26 24 11 32 19 18 36 8 10 9 1 13 15 16 17 14 12 21 20 23 27 28 33 CS RE9GKE CU RE9GKE CS RE12GKE CU RE12GKE...

Page 17: ...WAY VALVE 1 CWB011308 CWB011308 17 STRAINER 1 CWB11094 CWB11094 18 TERMINAL COVER 1 CWH171039 CWH171039 19 NUT FOR TERMIANL COVER 1 7080300J 7080300J 20 SOUND PROOF BOARD 1 CWH151173 CWH151173 21 SOUN...

Reviews: