Page 1: ...Model AW P Before attempting to connect operate or adjust this product please read these instructions completely Dial Up Adapter ...

Page 2: ...MENDED ACCESSORIES ONLY FCC Note This device complies with Part 15 of the FCC Rules To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection ...

Page 3: ...he controller it is possible to control a pan tilt head system consisting of up to 5 pan tilt heads It is possible to select any one of the pan tilt heads connected to the system using the camera switch signals O Control panels which can be used in the transmitting system AW RP301 AW RP501 AW RP505 and AW RP605 O Control panels which can be used in the receiving system AW PH300A AW PH350 AW PH500 ...

Page 4: ... perform menu settings These keys are also used to operate the pan tilt head system in direct mode When any key is operated with the key held down the function indicated in red on the key is enabled When any key is operated with the key held down the function indicated in blue on the key is enabled 5 LCD contrast control This is used to adjust the contrast of the LCD panel Turning this control clo...

Page 5: ...ble to control a pan tilt head system PAN TILT CONTROL IN connector This is used to connect the controller When an AW RP301 AW RP501 or AW RP505 is being used connect it to the PAN TILT CONTROL OUT connector When an AW RP605 is being used connect it to the EXTERNAL CONTROL OUT connector on the main unit Note An AW RP605 cannot be used for control in direct mode Control panel selector switch This i...

Page 6: ...e CONTROL button on the controller OWhen an AW RP301 AW RP501 or AW RP505 is being used as the controller an AW PH350 can not be used as the pan tilt head Version 45 or higher of the software must be installed in the AW RP605 Consult with your local dealer to check which software version is currently installed Telephone line Modem AW DU600 AW PS301 Coaxial cable 5C 2V 10Base T cable RS 232C cable ...

Page 7: ...P u l s e Transmitting system connection procedure 1 Connect the AW PS301 AC adapter to the DC 12V IN connector on this adapter 2 Set the control panel selector switch on this adapter Set it to A when using an AW RP605 Set it to B when using an AW RP301 501 505 or WV CB700A 5 Connect the TO MODEM connector to the RS 232C connector on the modem using the RS 232C cable provided with the modem 6 Set ...

Page 8: ...hone line Telephone line Modem Modem AW DU600 AW DU600 AW PS301 AW PS301 AW PS600 P T CONTROL AW CA50D15 component AW CA50A15 composite AW CA24U10 AW CA16U10 CAMERA CONTROL G L video BNC cable Video BNC cable COMPONENT AW CA50A15 AW PH300A AW CH600 AW PH600 AW PS300 AW CA28T9 Convertible camera Note Refer to the Operating Instructions of the AW PH600 for details on how to perform the connections f...

Page 9: ...d the pan tilt head is to exceed 10 m When an AW PH350 is used When an AW PH300A is used and the connection distance is more than 10 m Telephone line Modem AW DU600 AW PS301 Convertible camera Convertible camera AW PH350 AW PS300 10 Base T cable 10 Base T cable Telephone line Modem AW DU600 AW PS301 AW CA50A15 AW PH300A AW PS300 AC adapter AW CA28T9 RS 232C RS 422 converter AW CA50C29 component AW...

Page 10: ...S600 P T CONTROL CAMERA CONTROL G L video BNC cable Video BNC cable COMPONENT AW CH600 AW PH600 RS 232C RS 422 converter 10 Base T cable AC adapter AW CA50D15 component AW CA50A15 composite AW CA24U10 AW CA16U10 Note Refer to the Operating Instructions of the AW PH600 for details on how to perform the connections for the AW PH600 ...

Page 11: ...ating conditions STOP START START 2 MENU 4 Connect the pan tilt head to this adapter O If the connection distance between this adapter and the AW PH300A pan tilt head is 10 m or less use the AW CA28T9 10 m cable to connect the RS 232C CONTROL OUT connector on this adapter to the P T CONTROL IN connector on the AW PH300A O If the connection distance between this adapter and the AW PH300A pan tilt h...

Page 12: ...en an AW RP505 or AW RP605 is being used as the control panel it is possible to switch the receiving pan tilt head system using the CONTROL button on the control panel OIf the OPERATE switch on the AJ RP605 is set to ON before the telephone line is connected NO CONNECT is displayed on the LCD panel 5 After control of the pan tilt head is completed press the STOP key Hang Up appears on the LCD disp...

Page 13: ...13 Connections Direct mode Control the pan tilt head system directly using this adapter 1 AW DU600 AW PS301 AW CA50T29 composite AW CA50C29 component AW PH350 AW PS300 10 Base T cable Convertible camera ...

Page 14: ...s on and operation is possible 5 The pan tilt head system can be controlled in the following ways using the operating keys on this adapter Menuj 6 Output 2 P 1 P 2 P 3 P 4 P 5 2 Set the CONTROL OUT connector according to the type of pan tilt connected and the connection distance Press the key i to change the menu setting item When Menu 5 Output 1 appears on the LCD panel use the keys and select RS...

Page 15: ...ase T cable Convertible camera AW DU600 AW PS301 PC AW CA50T29 AW CA50T9 AW PH350 AW PS300 10 Base T cable Convertible camera Control the pan tilt head system using a control panel or PC 2 Coaxial cable 5C 2V 10Base T cable Note AW RP605 cannot be used as the control panel with direct mode ...

Page 16: ...WER switch on the control panel is set to OFF after control of the pan tilt head is completed the power of pan tilt head system will turn off Connection procedure 1 Connect the AW PS301 AC adapter to the DC 12V IN connector on this adapter 2 Set the control panel selector switch on this adapter to B 5 Dial Up Adapter settings 1 Set this adapter to direct mode Press the key i to open the menu setti...

Page 17: ...ne Tone Pulse External line transmission number settings None 0 and 9 and This is when the telephone line to be used is a pulse line This is for when an external line transmission number is not required This is for when 0 is to be transmitted via a PBX This is for when 9 is to be transmitted via a PBX This is for when this adapter is to be used as the transmitting system Tx Rx Direct This is for w...

Page 18: ...D panel If a telephone numbers has not been registered for the dial memory number the LCD panel display will be blank 3 Each time the key i is pressed the dial memory number is switched 4 Press the key to initiate the connection START STOP RECALL STOP RECALL This setting selects which connector is to be used for the controller when this adapter is in Direct mode TO RCB PC connector PC used for con...

Page 19: ...ch the internal wiring when reattaching the panels RS 232C CONTROL OUT P5 P4 P3 P2 P1 P5 P4 P3 P2 PAN TILT CONTROL IN CAMERA CONTROL IN GND DC 12V IN TO RCB PC A B P1 TO CAMERA PAN TILT HEAD TO MODEM RS 422 CONTROL OUT TO CAMERA PAN TILT HEAD TO CONTROL PANEL OUT PUT IN PUT 4 Use the three screws to firmly secure the blank panel where the rear panel was removed RS 232C CONTROL OUT P5 P4 P3 P2 P1 P...

Page 20: ...taching the joint angle adapter To attach the adapter to the controller use the joint angle adapter rack mounting adapter and mounting screws M4 x 8 supplied Rack mounting adapter Screw Joint angle adapters ...

Page 21: ...onnectors DC12V IN socket Connects the AW PS301 TO RCB PC AW CA50T10 when a WV CB700A is connected AW CA50T9 when a PC is connected PAN TILT CONTROL IN RJ45 Connects to PAN TILT CONTROL OUT on the remote control panel 10BaseT straight cable UTP category 5 max 500 meters CAMERA CONTROL IN BNC Connects to CAMERA CONTROL OUT on the remote control panel BNC cable 5C 2V max 500 meters Output connectors...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ... Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panasonic de Mexico S A de C V Av ang...