MAX

® 

5400-EX Owner’s Guide

Your audio/video components are constantly
being bombarded by electromagnetic interfer-
ence (EMI) and radio frequency interference
(RFI) through their power cords.  This contam-
inated power can affect audio/video equipment

and will degrade the overall performance of
your entire system.  Common symptoms of
contaminated power include pops, hisses,
hums and visual artifacts.   

The MAX 5400-EX is designed to filter this
noise, supply clean power to your system and
provide noise isolation between the outlet
banks so that any noise created by an A/V com-

ponent can not contaminate the power going to
equipment plugged into the other outlet banks.  

Sequential Startup/Shutdown:

Complex audio/video systems may be suscep-
tible to voltage transients generated internally
at start-up/shutdown if all of the equipment is
powered on or off at the same time.  This can
cause speaker “thumps” which are not only
annoying but can also damage the speakers.
The MAX® 5400-EX is designed to eliminate
these transients by providing a “start-up” delay
for the High-Current outlets and a “shutdown”
delay for the Switched Outlet Bank.  This allows
the components plugged into the Switched
Outlet Bank to power-up and stabilize before
any amplifiers and powered sub-woofers are
turned on.  This sequence is reversed during
shutdown.  The amplifiers and powered sub-
woofers turn off, their power supplies drain,
and then the equipment plugged into the
Switched Outlet Bank is turned off.

Voltage Sense Trigger:

This feature provides an ON/OFF trigger for the
MAX® 5400-EX using a Direct Current voltage
signal.  Many components such as pre-ampli-
fiers and receivers have a DC trigger built in,
and will transmit a constant power signal when
turned on and in use.  The presence of this
power signal will turn on the MAX® 5400-EX’s
switched outlets.  When the source component
is turned off, the voltage trigger signal is also
turned off and the MAX ® 5400-EX’s shutdown
sequence is initiated.  An AC Adapter of the
appropriate voltage, plugged into a switched
outlet, may also be used if a DC trigger is not
built in.    

The MAX® 5400-EX voltage sense trigger input
uses a standard 3.5mm (1/8") mini-plug jack.
This jack has an electrically isolated switch built
in.  If nothing is inserted into the input jack, the
voltage sense is bypassed and the Power
Button on the front panel has sole control of the
startup/shutdown sequence.  If a plug is insert-
ed into the input jack, the front panel switch is
bypassed and the voltage sense becomes the
startup/shutdown trigger.  

IMPORTANT, Please

Note: 

The unit needs to be plugged in, and in

the powered OFF state before inserting the DC
input trigger mini-plug.

A trigger output is also provided on this model.
When a DC trigger is connected to the MAX®
5400-EX’s Voltage Sense input, the input signal
can be passed through the output jack to con-
trol the startup/shutdown of an additional
device.  There is a 10 second delay between
when the MAX® 5400-EX receives the input
signal and when it is output to the next device.

Automatic Over & Under Voltage Protection:

Panamax’s patent pending power monitoring
circuitry constantly monitors the AC line volt-
age for unsafe voltage conditions such as pro-
longed over-voltages and under-voltages
(brownouts).  These unsafe conditions pose a
very dangerous threat to all electronic equip-
ment within the home.  If the MAX® 5400-EX
senses an unsafe power condition, it will auto-
matically 

disconnect 

your equipment from the

power to protect equipment from damage.
Once the voltage returns to a safe level, the
MAX® 5400-EX will automatically 

reconnect

the power.

Protect or Disconnect AC Surge Protection:

When the MAX® 5400-EX is subjected to a
high voltage surge, its voltage output is limited
to a safe level and the high levels of surge cur-
rent are diverted away from the connected
equipment.

• When subjected to a 6,000V (open circuit
voltage) / 500A (short circuit current) surge,
the MAX® 5400-EX limits its voltage output to
less than 330V peak, UL’s best rating.  The
MAX® 5400-EX will withstand, without dam-
age, 20,000A surges, far exceeding the UL
requirement of only 3000 Ampere surges.

• If the magnitude of the surge is greater than
the capacity of the surge protection compo-
nents, the MAX® 5400-EX's Protect or
Disconnect‘ Circuitry will disconnect your
equipment in order to protect it.   The MAX®
5400-EX will need to be repaired or replaced by
Panamax if this occurs.

Application Specific Coaxial Signal Line
Protection:

Panamax's exclusive SignalPerfect™ Technolo-
gy provides application specific protection for
your satellite and cable TV equipment.  Two
lines of protection are provided for each type.
The satellite connection is for a coaxial cable
connected to a DBS (single or dual LNB) satel-
lite dish.  The antenna connection is for a non-
amplified off-air antenna or cable TV line.   

The protection circuitry has been optimized for
each application and is not interchangeable.
The jacks are not labeled In and Out.  The cir-
cuitry is bidirectional in both signal transmis-
sion and protection capabilities, making it com-
patible with the latest digital cable and satellite
technologies.

Cable TV (Including HDTV) 

– TV tuners oper-

ate at approximately 10 millivolts (0.01 V) and
utilize the frequency spectrum up to 950 MHz.
The clamping level of the MAX® 5400-EX's
cable TV protection circuitry is 1400 millivolts
(1.4 volts).  That's less than 1 volt above nor-
mal operating levels.  The circuitry is also
shielded to prevent interference.

Satellite TV

- Satellite dish LNB's can require

up to 24 volts to operate and utilize the fre-
quency range of 950 MHz to 2.2 GHz.  The
clamping level of the MAX® 5400-EX's satellite
protection circuitry is 25 volts - just 1 volt
above the maximum operating voltage.  The
circuitry is also shielded to prevent interfer-
ence.

Telephone Line Protection:

Digital video recorders and satellite TV
receivers require a telephone line connection
for TV show scheduling and/or Pay-Per-View
services.  The MAX® 5400-EX also provides
surge protection for this line.  One pair of RJ-
11 telephone jacks is provided for this.  The cir-
cuitry utilizes auto-resetting PTCRs and solid-
state SIDACtors“ for reliability and unsur-
passed protection.  The clamping level of the
MAX 5400-EX's telephone protector is 260
volts.  This will allow typical ring voltage (90-
130VAC) and operating battery voltage (-48DC)
to pass through the circuit and still protect the
modem in your satellite receiver from damage.  

Home Theater Power Conditioner

M5400-EX

BANK 1 

ALWAYS ON

BANK 2

ALWAYS ON 

BANK 3

ON

BANK 4

ON

BANK 5

ON

WIRING

OK

METER

LIGHTS

AMPS

VOLTS

POWER AND 

FILTRATION

Key Features

LEVEL 5 EMI/RFI Noise Filtration with Isolation Between Outlet Banks:

Model: 

M5400-EX

INS0787E   Rev A   5/05

Summary of Contents for M5400-EX

Page 1: ...s These unsafe conditions pose a very dangerous threat to all electronic equip ment within the home If the MAX 5400 EX senses an unsafe power condition it will auto matically disconnect your equipment from the power to protect equipment from damage Once the voltage returns to a safe level the MAX 5400 EX will automatically reconnect the power Protect or Disconnect AC Surge Protection When the MAX ...

Page 2: ...ion is pro vided by the Isolation Transformer in con junction with a three stage balanced Pi fil ter Banks 3 and 4 are noise isolated from each other as well as all other outlet banks Outlet Bank 5 Two switched high current outlets controlled by the front panel Power Button or the DC Trigger input Bank 5 has a 5 second turn on delay and turns off immediately The High Current outlets pro vide power...

Page 3: ...e F Gold Plated AC Power Line Voltage 120V 60Hz Total Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Energy Dissipation 1815 Joules Peak Impulse Current 73 000 Amps Catastrophic Surge Circuit Yes Thermal Fusing Yes Over voltage shutoff 142 VAC 5 VAC Under voltage shutoff 90 VAC 3 VAC EMI RFI Noise Filtration Banks 1 4 100 db 100 KHz 2 ...

Page 4: ...connecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protector for surge damage The Panamax protector must show signs of surge damage or must be performing outside 10 of design specifications relative to its surge protection capability Opening the enclosure tampering with or modifying the unit in any way shall be grounds for an automatic denial of your request for payment...

Page 5: ...cción automática de sobretensión y subtensión El circuito monitoreando la corriente que actualmente tiene una patente pendiente con stantemente monitorea la tensión de línea CA para condiciones de tensiones peligrosas tales como sobretensiones prolongadas y subten siones Estas condiciones pelig MAX 5400 EX rosas representan una amenaza a todo equipo electrónico dentro de la casa Si el MAX 5400 EX ...

Page 6: ...ediatamente se apagarán despúes de 10 segundos Filtración de ruido EMI RFI es proporcionado por un circuito toma de cua tro etapas filtro equilibrado Pi El ruido es aislado de Banco 3 y 4 al igual de los otros bancos de tomacorrientes Jacks coaxiales de TV en cable Circuito de protección bidi reccional ha sido optimizado para cables de TV en cable antenas fuera de aire y modems de cable No Para Us...

Page 7: ...z Conexiones Hembra F Enchapado en Oro Energía CA Tensión de Línea 120V 60Hz Capacidad de Corriente total 15 A Clasificación UL1449 para supresión 330V Modos de Protección L N L G N G Nivel de Sujeción 200V Disipación de Energía 1815 Joules Corriente Máxima de Impulso 73 000 Amps Circuito de sobrecarga catastrófica Si Fusión Térmica Si Interruptor de sobre tensión 142 VAC 5 VAC Interruptor de sub ...

Page 8: ...0 días Antes de desconec tar su sistema favor diagrame de su configu ración porque un diagrama de su sistema se requerirá como parte de sus documentos de reclamo 4 DETERMINACION DE FALLA El protector será evaluado para daño causado por tensión por Panamax El protector Panamax debe mostrar daño por tensión o debe estar funcionando fuera 10 de las especificaciones de diseño relativo a su capacidad d...

Page 9: ...rge ment l exigence de UL relative aux surinten sités qui n est que de 3 000 A S il arrivait que la surtension excède la capacité des composantes de protection con tre les surtensions le circuit Protect or Disconnectmc du MAX 5400 EX couperait l alimentation de votre matériel pour le pro téger Dans ce cas il faudrait confier le MAX 5400 EX à Panamax à des fins de réparation ou de remplacement Prot...

Page 10: ...ant dépasse 15 A Enfoncez le pour le réini tialiser Banc de sorties 1 et 2 Deux prises toujours sous tension L alimentation n est coupée qu en présence d une anomalie Voir les fiches techniques pour connaître les seuils de surtension et de sous tension L alimentation pour chaque banc est nettoyée au moyen d un filtre en pi équilibré à quatre étages Les bancs 1 et 2 sont isolés l un de l autre en c...

Page 11: ...Fusion thermique Oui Coupe circuit de surtension 142 V c a 5 V c a Coupe circuit de sous tension 90 V c a 3 V v a Filtrage du bruit EMI IFR Banc de sorties 1 à 4 100 db 100 KHz 2 MHz Banc de sorties 5 sorties à haute intensité 60 db 100 KHz 2 MHz Entrée du déclencheur c c Prises Mini prise de 3 5 mm 1 8 po Tension et polarité 3 à 24 V c c bidirectionnel Exigence de courant 4 6 mA à 3V 58 mA à 24V ...

Page 12: ...emande de numéro d autorisation de retour Panamax vous postera une trousse de demande de règlement que vous devrez remplir et retourner dans les 30 jours Un schéma de câblage de votre système sera exigé Assurez vous de noter la configuration de votre système avant de le débrancher 4 CONFIRMATION DE LA DÉFECTUOSITÉ Panamax examinera l appareil de protection afin de déterminer s il a subi des dommag...

Reviews: