background image

INTERNATIONAL LTD

TECHNICAL BULLETIN

PAC International Limited. 1 Park Gate Close, Bredbury, Stockport,SK6 2SZ, England

Tel: +44 (0) 161 406 3400. Fax: +44 (0) 161 430 8658

www.pac.co.uk

Using Externally powered Short Haul Modems with EK1000N

June 2000

TB33 Ver 1.0

Introduction

This Technical Bulletin describes how to connect an Easikey 1000N, with externally powered
short haul modems (SHM), to a PTSN modem via a COS dataswitch.

Product Tested:

Blackbox Powered Short Haul Modem (B Plus Async)

Product Code:

ME800AE Plus

Power is supplied to the SHM via a 17V 0.7A power supply.

System Configuration

EasiKey 1000-N

Short-haul modems

COS Dataswitch

PSTN Modem

Wiring Details

EK1000N to Short Haul Modem

Note:

The SHM requires a 25 way, male, D-type connector.
The SHM must have switch S1 set to DTE and switch S2 set to EN (both switches are
located in a recess on the underside of the modem).

EK1000N 

 
 

RX 

TX 

GND 

CTS 

DRT 

Short Haul 
Modem 

 
PIN 2 
PIN 3 
PIN 7 
PIN 5 
PIN 20 