background image

INSTRUCTION MANUAL 

MODE D’EMPLOI

FOR YOUR OWN SAFETY, PLEASE READ THIS INSTRUCTION MANUAL 

CAREFULLY BEFORE YOU INITIALLY START-UP

POUR VOTRE SÉCURITÉ, MERCI DE LIRE ATTENTIVEMENT

CE MODE D’EMPLOI AVANT D’UTILISER VOTRE PRODUIT

TM4BOX

V1.0 11/2021

Summary of Contents for TM4BOX

Page 1: ...E D EMPLOI FOR YOUR OWN SAFETY PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE YOU INITIALLY START UP POUR VOTRE S CURIT MERCI DE LIRE ATTENTIVEMENT CE MODE D EMPLOI AVANT D UTILISER VOTRE PRODUI...

Page 2: ......

Page 3: ...iew 5 4 Operation guide 6 5 Connection diagram 8 6 Connector pinout 8 7 Technical data 9 FRAN AIS TM4BOX MODE D EMPLOI Page 1 Dans la bo te 10 2 Instructions 10 3 Aper u 11 4 Guide d utilisation 12 5...

Page 4: ...g removed the packaging check that the unit is NOT damaged in any way If in doubt DON T use it and contact an authorized dealer NEVER use the unit under the following conditions In places subject to e...

Page 5: ...ew 8 2 7 6 3 10 4 9 5 11 1 1 CEE 5 pole 32A Power supply 400V 3P N PE 2 CEE 4 pole 16A Socket 3 16 pole multi connector Harting 4 Circuit breaker 5 UP DOWN OFF button 6 GO button 7 Green Run LED 8 Eme...

Page 6: ...4 pin cable 4 Operation guide The motors hoists connected to the TM4BOX controller can be activated individually or simultaneously using the GO button located on the front panel via cable remote or b...

Page 7: ...tion In this mode controller is operated by GO and E STOP buttons located either on the front panel or on the REMOTE Controller link operation In this mode all linked controllers are operated by any G...

Page 8: ...User Instruction TM4BOX V1 0 11 2021 8 16 5 Connection diagram 6 Connectors pinout...

Page 9: ...BOX V1 0 11 2021 9 16 7 Technical data VOLTAGE 400V 3P N PE Max LOAD PER MOTOR SWITCH 1kW 1 5A 400V MAX LOAD TOTAL ALL OUTPUTS SUMMED 6 9kW 10A 400V MAX AMBIENT TEMPERATURE 40 C DIMENSION 514 x 414 x...

Page 10: ...mag de quelque fa on que ce soit En cas de doute NE l utilisez PAS et contactez un revendeur agr N utilisez JAMAIS l appareil dans les conditions suivantes Dans des endroits soumis une humidit excessi...

Page 11: ...3 10 4 9 5 11 1 1 CEE 5 p les 32A Alimentation 400V 3P N PE 2 Prise CCE 4 p les 16A 3 16 p les multi connecteur Harting 4 Disjoncteur 5 Bouton HAUT BAS OFF 6 Bouton GO 7 LED verte RUN 8 Arr t d urgen...

Page 12: ...ble XLR 4 broches 4 Guide d utilisation Les moteurs palans connect s au contr leur TM4BOX peuvent tre activ s individuellement ou simultan ment l aide du bouton GO situ sur le panneau avant via une t...

Page 13: ...r leur est actionn par les boutons GO et E STOP situ s soit sur le panneau avant soit sur la T L COMMANDE Fonctionnement de la liaison contr leur Dans ce mode tous les contr leurs li s sont actionn s...

Page 14: ...Mode d emploi TM4BOX V1 0 11 2021 14 16 5 Sch ma de connexion 6 Brochage des connecteurs...

Page 15: ...6 7 Donn es techniques TENSION 400 V 3P N PE CHARGE MAX PAR INTERRUPTEUR MO TEUR 1 kW 1 5A 400V CHARGE MAXIMALE TOTALE TOUTES LES SORTIES ADDITIONN ES 6 9 kW 10 A 400 V TEMP RATURE AMBIANTE 40 C DIMEN...

Page 16: ......

Reviews: