background image

LASER LEVEL - USER MANUAL

  SHIELDED CROSS LINE LASER

 

 INDOOR/OUTDOOR & TILT MODE

 

WATER & DUST PROOF
RANGE UP TO 60M

OX-P502901

oxtools.com

Summary of Contents for OX-P502901

Page 1: ...LASER LEVEL USER MANUAL SHIELDED CROSS LINE LASER INDOOR OUTDOOR TILT MODE WATER DUST PROOF RANGE UP TO 60M OX P502901 oxtools com ...

Page 2: ...t the most out of your laser tool APPLICATIONS The OX Pro Series Laser Level is innovatively designed for a very broad range of professional and DIY jobs including Aligning tiles cabinets borders moldings and trimmings Doors and windows installation All types of DIY jobs including hanging shelves pictures and more NOTE Keep this user manual for future reference ...

Page 3: ...EVEL USER MANUAL 03 FEATURES 4 SAFETY INSTRUCTIONS 5 6 BATTERY INSTALLATION SAFETY 7 8 OVERVIEW 9 OPERATING INSTRUCTIONS 10 12 MAINTENANCE 13 FIELD CALIBRATION TEST 14 19 SPECIFICATIONS 20 WARRANTY 21 CONTENTS ...

Page 4: ...ulses that can be detected by a detector The max Detectable range of the laser in pulse mode is 60m 200 Manual mode allows angular layout marking IP65 Rated for water and dust protection Locking mechanism to protect the pendulum during transportation tripod adaptor Shock resistant rubber casing Compact size fits in your toolbox NOTE This device contain precision components that are sensitive to ex...

Page 5: ...aser level Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope as this will increase the level of eye injury WARNING This product contains lead in solder and certain Electrical parts contain chemicals which are known to the State of California to cause cancer birth defects or other Reproductive harm California Health Safety Code Section 25249 6 Proposit...

Page 6: ...0 C or above 45 C 14 F 113 F Do not operate the laser in explosive atmospheres such as flammable liquids gases or dust Sparks from the tool can cause ignition When not in use turn off the power engage the pendulum lock and place the laser in the carrying pouch Make sure the pendulum lock mechanism is engaged before transporting the laser NOTE If the pendulum lock mechanism is not engaged before tr...

Page 7: ...rand according to the polarity diagram on the inside of the lid of the battery compartment 3 Reclose the battery cover NOTE If the laser level will not be used for a long period remove the batteries from the battery compartment This will prevent batteries from leaking and corrosion damage BATTERY INSTALLATION SAFETY ...

Page 8: ...rten the battery terminals 2 Do not charge Alkaline batteries 3 Do not mix old and new batteries 4 Do not dispose of batteries into household waste 5 Do not dispose batteries in fire 6 Defective or dead batteries must be disposed according to local Regulations 7 Keep the batteries out of reach from children ...

Page 9: ...ANUAL 09 1 On Off Locking Switch 2 Laser output window 3 Keypad a Manual Mode button b Beam Selector button c Pulse Mode button d Manual Mode LED e Laser beam LED f Pulse mode LED 4 Battery cover 5 tripod mount OVERVIEW ...

Page 10: ...er level will generate the crossed horizontal and vertical beams and the green LED near the V H button will light up 3 Choose the beams that you want to work with by pushing the Beam button V H 4 If the initial slope of the laser is beyond 3 and the automatic mode is activated the laser lines will flash and a beeping alarm will be heard In this case reposition the laser on a more leveled surface 5...

Page 11: ...ed LED near the button will light up The green LED of the laser beams near V H button will light up as well 2 Choose the beams that you want to work with by pushing the Beam Selector button V H 3 To mark a slope tilt the laser to adjust the right angle and the height 4 To turn the manual mode off press again the Manual mode button 5 While in Manual mode turning the locking switch 1 from OFF to ON ...

Page 12: ...conditions and for extended indoor ranges up to 60 meters use the pulse mode with a Detector When the pulse mode is activated the laser lines will flash at very high frequency Invisible to the human eye this will allow the detector to detect the laser lines 1 The pulse mode can be activated in Automatic and Manual modes 2 To switch on the Pulse Mode press the P button the green LED near the P push...

Page 13: ...laser level with a clean soft cloth Do not use solvents Although the laser level is dust and dirt resistant to a certain degree do not store in dusty places as a long term exposure may damage internal moving parts If the laser level is exposed to water dry the laser level before returning it to the carrying case to prevent corrosion damages Remove the batteries if the laser level is unused for a l...

Page 14: ...k the leveling accuracy of the vertical line Checking the Height Accuracy of the Horizontal Line Up and down deviation 1 Set up the laser on a tripod or on a solid surface between two walls A and B approximately 5 meters apart 2 Position the laser level approximately 0 5 meter from wall A 3 Unlock the pendulum and press the button to project the horizontal and the vertical cross lines towards wall...

Page 15: ...rds wall B and mark on the wall the center of the cross lines as b1 see figure 2 6 Move the laser level towards wall B and position it approximately 0 5 meter from wall B 7 Mark on wall B the center of the cross lines as b2 see figure 3 Figure 3 Figure 2 ...

Page 16: ...more than 2 mm otherwise to send the laser level to a qualified technician for repairs Checking the Level Accuracy of Horizontal Line Side to side inclination 1 Set up the laser on a tripod or on a solid surface at a distance of approximately 1 5 meters from a wall 5 meter long 2 Unlock the pendulum and press the button to project the horizontal and the vertical cross lines towards the wall Figure...

Page 17: ...rizontal line at the left edge of the horizontal line see figure 5 4 Turn the laser level counterclockwise until the right edge of the horizontal line reach s near a1 mark a point a2 on the wall in the middle of the horizontal line see figure 6 Figure 6 approximately 5m Figure 5 ...

Page 18: ...After the plumb line has settled Mark point a1 on the wall behind the plumb line near the plumb cone see figure 7 3 Set up the laser on a tripod or on a solid surface in front of the wall at a distance of approximately 2 meters 4 Unlock the pendulum and press the button to project the vertical line toward the plumb line 5 Turn the laser so that the vertical line will merge with the plumb line belo...

Page 19: ...point a2 on the wall in the middle of the vertical line at the same height of a1 see figure 8 7 The distance between a1 and a2 should not be more than 1mm otherwise to send the laser level to a qualified technician for repairs Figure 8 ...

Page 20: ...uracy 0 2m m 0 0002in in Fan angle 120 5 Self leveling range 3 Laser line width 2mm 0 5mm 5m 0 10 0 02 at 20 Wavelength 525 5nm Laser Class II Power supply 3 AA batteries included Battery life 6 hours of continuous operation Operating temp 10 C 45 C 14 F 113 F Storage temp 20 C 70 C 4 F 158 F Water dust proof IP65 Dimensions 10cm x 9cm x7cm 3 9 x 3 5 x 2 8 SPECIFICATIONS ...

Page 21: ...does not cover products that are used improperly altered or repaired without OX s approval In the event of a problem with the laser level you have purchased please return the product to the place of purchase with the proof of purchase OX P502901 The serial number sticker is positioned on the lid of the battery compartment WARRANTY ...

Page 22: ...oxtools com 22 NOTES ...

Page 23: ...LASER LEVEL USER MANUAL 23 ...

Page 24: ... OX Products Group UK Ltd ...

Reviews: