background image

Quick Start Guide

RDX

®

 

QuikStation

®

 

8

2U Storage Appliance

Step 1

Register the Unit

It is 

essential

 to activate your warranty. Technical and warranty 

support are 

not available

 until the warranty is active:

1.

Go to 

https://www.overlandtandberg.com/service-support/customer-

product-registration/

.

2.

Click 

Register

.

3.

Fill in the information (including serial number) and click 

Submit

.

Your warranty certificate will be emailed to you. Follow the email 

instructions to complete the registration process.

Step 2

Unpack the Unit

Place the unit and any supplied RDX cartridges on a secure surface.

WARNING:  

To reduce the risk of electric shock or damage to 

equipment, always remove any power cords while working with 
the unit.

WARNUNG: 

Um das Risiko eines elektrischen Schlags oder 

Schäden am Gerät zu vermeiden, ziehen Sie stets den 
Netzstecker, bevor Sie an der Einheit arbeiten.

AVERTISSEMENT:  

Pour réduire le risque de choc électrique ou 

endommagement de l'équipement, retirez toujours les cordons 
électriques en travaillant avec l'appareil.

Save the packaging materials in case the unit is returned or shipped for 

any reason.

Step 3

Install Rails in Rack

The rack version of the RDX QuikStation 8 is designed for use in a 

19-inch rack using 2U of rack space. The rails are installed at the bottom 

of a 2U space. 

NOTE: The length of the power cord and the Ethernet cables may restrict 

placement.

Ensure that the airflow around 

the front and back of the unit is 

not obstructed, dust is kept to a 

minimum, and there is at least 

12cm (4.75 in.) free space in front 

of the unit to allow the operators 

to safely remove the RDX 

cartridges.

1.

Determine the 

2U area

 

where the QuikStation 8 is to 

be mounted and mark both 

sets of 

first

 and 

third holes

 

of the bottom 1U on the front.

2.

At the rear, mark the same 

first

 and 

third holes

.

3.

Measure

 the gap between the 

front and rear rack rails. 

If the measurement is

 less

 

than the length of the 

QuikStation 8, secure the 

first 

and 

third

 mounting 

rail holes with M4x12 

screws, washers, and nuts.

If the measurement is

 equal 

or greater

 than the length 

of the QuikStation 8, secure 

the 

second 

and 

fourth

 

mounting rail holes with 

M4x12 screws, washers, and nuts.

4.

Align the 

left-front flange

 with the two marked holes on the front 

rack rail and loosely attach the left-side mounting rail with two 

screws.

5.

Ensure the mounting rail is level and attach it loosely to the 

rack 

rear

 with two screws.

6.

Repeat 

Steps 4–5

 for the 

right-side rail

.

7.

Verify both rails are level and securely tighten 

all screws

.

Installing the Unit in the Rack

1.

Lift and position the 

unit

 onto the 

rails and push it in until the front 

brackets are touching the rail screws.
Verify that the unit is level and the 

QuikStation 8 thumbscrews align 

with the appropriate rail holes.

2.

Using the 

thumbscrews

, anchor the 

QuikStation 8 bracket right and left 

to the rack.

WARNING:  

Do not place anything on top of the rack-mounted unit 

when it is extended from the rack.

WARNUNG: 

Stellen Sie nichts auf die Rackeinheit, wenn diese aus 

dem Rack herausragt.

AVERTISSEMENT:  

Ne rien poser sur l’unité installée dans le rack 

lorsqu’elle est étendue du rack. 

QuikStation 8

Mark

Mark

(Front)

2U

Use these holes if the

rack rail’s gap < unit length

Use these holes if the

rack rail’s gap 

 unit length

Front

Thumbscrew

Step 4

Connect Network Cables and Power Cords

All power connections, cable ports, and cooling vents are located on the 

rear panel of the QuikStation 8.

1.

Connect either one or both of the 10 Gb Ethernet ports to the 

network

 ports of a switch, hub, or router on the same LAN as the 

host system being used to manage the QuikStation.

NOTE: For failover protection and maximum performance, connect both 

10 GbE network ports.

2.

Connect the appropriate power cords to the QuikStation,

 

and plug 

the 

power cords

 into either a UPS appliance or a properly 

grounded AC power source.

NOTE: If using two power supplies for failover protection, connect them to 

different UPS appliances using different AC power sources.

3.

Turn the power on by pressing the 

power button

 on the front 

center of the unit.

Install Cartridges

1.

Position an 

RDX cartridge

 at an empty RDX dock opening with the 

“key” (angled edge) at the upper left.

2.

Push the 

cartridge 

in until it locks in place.

3.

Repeat 

Steps 1–2

 for 

each

 remaining cartridge.

Step 5

Obtain the IP Address

The default QuikStation 8 network configuration is set for dynamic IP 

addresses (DHCP), but static IP addresses are also supported. Use one of 

these two ways to determine an IP address:

USB

:

1.

Using a USB stick with a single MBR partition formatted with 

either FAT32 or NTFS, create an empty 

network.info

 

file

 on it.

2.

Insert the stick

 in the USB port on the front of the unit and wait at 

least 30 seconds for the network information to download to the file.

3.

Move the USB stick to a 

host computer

 and scan the updated 

network.info

 

file to determine the available IP addresses.

Video Monitor

:

1.

With the appliance off, attach a 

monitor

 to the VGA display port.

2.

Attach a 

keyboard

 as appropriate.

3.

Power on

 the unit by pressing the power button.

After the unit initializes, the IP addresses are displayed.

Version 3

1 - AC Power plugs (on PSUs)

2 - Power Supply Reset

3 - Serial connector

4 - Ethernet port - IPMI Interface

5 - USB 2.0 Ports (2)

6 - USB 3.0 Ports (2)

7 - 10 Gigabit Ethernet port (eth0)

8 - 10 Gigabit Ethernet port (eth1)

9 - VGA connector

1

2

5

4

6

3

7

9

8

*10401048

­

002*

10401048-002