background image

1

GB

Multi-Channel Indoor-Ooutdoor

Thermohygrometer with

Cable Free

TM

 Sensor & ExactSet

TM

 Clock

MODEL: RMR-136HG

INTRODUCTION

Thank you for purchasing the RMR-136HG Multi-Channel Indoor-
Outdoor Thermohygrometer with Cable Free

TM 

sensor, model

THGR268, and ExactSet

TM

 calendar clock.

This basic configuration consists of the main unit that is the
temperature and calendar clock station, and the  thermohygrometer
sensor remote unit. The main unit can support up to 3 remote
sensors.  Additional remote sensors are available.

The main unit has a large easy-read LCD screen that displays the
indoor temperature, clock with calendar, and temperature and
humidity data transmitted by the remote sensor to the main unit.
The RMR-136HG also records the maximum and minimum
indoor temperatures, and the maximum and minimum
temperatures/humidity data transmitted from the remote sensor.

The clock is a radio-controlled ExactSet

TM

 clock and includes a

calendar. The clock automatically synchronizes time and date with
radio signals received from the US Atomic Clock, one of the world’s
most accurate timepieces.   Other  clock/calendar features include
three-language choice for day-of-the-week display, a four-step
crescendo alarm and easy-change display modes. (To learn more
about the US Atomic Clock visit the US Department of Commerce's
National Institute of Standards and Technology website at:
www.nist.gov.)

MAIN UNIT FEATURES

D

B

A

E

C

G

M

D

AM

C

P M

E

H

I

F

O

S

L

K

J

R

Q

RMR136HG

Remote Therm-Hygro

Tested To  Comply

 With FCC Standards

FOR HOME OR OFFICE USE

Model No. RMR136HG

P

N

M

CHANNEL

MEMORY

SET   /   MODE

DAILY

E X A C T S E T     R A D I O     C O N T R O L L E D

C A B L E     F R E E

Summary of Contents for RMR-136HG

Page 1: ...rds the maximum and minimum indoor temperatures and the maximum and minimum temperatures humidity data transmitted from the remote sensor The clock is a radio controlled ExactSetTM clock and includes...

Page 2: ...and humidity data from remote sensor and the main unit H ALARM ICON Indicates that the alarm time is displayed I ALARM ON ICON Is displayed when the alarm is activate J WALL MOUNT RECESS For mounting...

Page 3: ...ade C or Fahrenheit F D CHANNEL SLIDE SWITCH Assigns the channel number to the remote sensor E RESET Returns all settings to their original default values F BATTERY COMPARTMENT Accommodates two AA siz...

Page 4: ...nit and the remote sensor 4 Position the remote sensor within the effective transmission range of 21 32 yards 20 30 meters from the main unit See Wireless Transmission for important information about...

Page 5: ...OW BATTERY WARNING The RMR 136HG features a low battery warning icon This icon will appear on the second line of the LCD screen when the main unit batteries are low and need replacing To determine low...

Page 6: ...humidity readings Press CHANNEL to sequence through the choices of Indoor or remote sensor channel 1 2 or 3 If readings are not received from a remote sensor after 15 minutes blanks will be displayed...

Page 7: ...e the remote sensor scanning mode Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Press any button MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minim...

Page 8: ...e low minimum limit will start at 2 and the high maximum limit at 98 After the initial setting the limits will start from the humidity levels as last selected NOTE Alarm Sounding If a set limit is exc...

Page 9: ...erent location and or closer to the main unit CALENDAR CLOCK DISPLAY MODES The RMR136HG has two different time display modes To turn the alarm off 1 While the alarm is sounding press HI LO 2 Then pres...

Page 10: ...receiving icon will flash once the signal reception is complete the icon will stop flashing MODE 1 Local Time Hour Minute Second Month Day MODE 2 Local Time Hour Minute Day of the Week Month Day Pres...

Page 11: ...TIVATING DISABLING THE CLOCK ALARM To active the daily alarm press AL ON OFF When the alarm is active a bell icon will appear in the lower left corner of the LCD screen If the alarm is not active ther...

Page 12: ...r all settings and then reinsert the batteries CUSTOMER ASSISTANCE Should you have questions or require additional information about this product please contact our Customer Service Department at 800...

Page 13: ...S Temperature Measurement Main unit Proposed operating range 23 0 F to 122 0 F 5 0 C to 50 0 C Temperature resolution 0 2 F 0 1 C Temperature compensation 14 0 F to 140 0 F 10 0 C to 60 0 C Relative h...

Page 14: ...equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harm...

Page 15: ...rinting limitations the displays shown in this manual may differ from the actual product displays The manufacturer and its suppliers hold no responsibility to you or any other claim arising by using t...