INSTRUCTION MANUAL

OPTISTAR By OPTIKA Series

Model

OS-SZ1
OS-SZ2

OS-SZ3

OS-SZ4
OS-SZ5
OS-SZ6

Summary of Contents for OPTIStar OS-SZ1

Page 1: ...Ver 1 0 2021 INSTRUCTION MANUAL OPTISTAR By OPTIKA Series Model OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 2: ...nocular model 7 7 1 6 Connecting the power supply 7 7 2 OS SZ3 OS SZ4 7 7 3 OS SZ5 OS SZ6 10 7 4 Installing Ringlight illuminator OS SZ3 OS SZ6 12 8 Use of the microscope 13 8 1 Adjusting interpupilla...

Page 3: ...se follow the guidelines below and read this manual in its entirety to ensure safe operation of the unit 3 Unpacking The microscope is housed in a moulded Styrofoam container Remove the tape from the...

Page 4: ...nt description 6 1 OS SZ1 OS SZ2 BASE TRANSMITTED LIGHT ON OFF INTENSITY CONTROL KNOB HORIZONTAL ARM HORIZONTAL ARM FIXING KNOB PILLAR RINGLIGHT LED ILLUMINATOR DROP PREVENTION RING PILLAR FIXING KNOB...

Page 5: ...tor LOCKING SCREWS FIXING RING SOCKET FOR POWER SUPPLY LIGHT INTENSITY KNOB LED ILLUMINATOR ON OFF SWITCH DROP PREVENTION RING BASE RINGLIGHT LED ILLUMINATOR MICROSCOPE BODY OS SZ5 BINOCULAR OS SZ6 TR...

Page 6: ...hed tighten the locking knob located on the back of the focusing system Fig 1 7 1 4 Installing the eyepieces Remove the dust caps from the eyepiece sleeves and insert the eyepieces Fig 4 F Fig 2 ig 2...

Page 7: ...to leave the fixing screw of the photo adapter facing right 3 Lock the fixing screws F Fig 8 ig 8 F Fig 7 ig 7 F Fig 5 ig 5 7 1 6 Connecting the power supply Connect the power supply plug to the sock...

Page 8: ...g knob Fig 9 F Fig 10 ig 10 F Fig 11 ig 11 F Fig 12 ig 12 4 Insert the horizontal arm and secure it with the fixing screw Fig 10 11 5 Install the head holder Unscrew the locking knob and in sert the a...

Page 9: ...ghten the fixing screw Fig 13 F Fig 14 ig 14 F Fig 15 ig 15 7 Insert from below the focusing system tighten the fixing screw and re tighten the locking knob from below Fig 14 15 8 Repeat steps from 7...

Page 10: ...6 ig 16 F Fig 17 ig 17 F Fig 19 ig 19 F Fig 18 ig 18 2 Tighten the screw to lock the pillar Fig 17 3 Insert the drop preventing ring and fix it at the desired height by screwing the fixing knob Fig 18...

Page 11: ...provided Allen wrench Fig 20 F Fig 22 ig 22 6 Install the head holder Unscrew the prevention knob and insert the head holder from below in the pillar Lock the fixing knob At the end screw again the pr...

Page 12: ...tor OS SZ3 OS SZ6 1 Screw the fixing ring on the bottom of the Stereo head Fig 23 2 Place the illuminator on the fixing ring using the three lock ing screws Fig 24 3 Connect the power supply jack to t...

Page 13: ...tting the height of the microscope Fig 27 8 3 Adjusting the tension of the focus knob This adjustment allows to increase or decrease the ten sion of the knob by avoiding an involuntary descent of the...

Page 14: ...he right eyepiece Fig 30 until the image of the right eyepiece is clear and sharp Repeat the procedure for the left eyepiece 5 Check the focus of the image for the whole zoom range It should be perfec...

Page 15: ...ity of the incident light LED It is possible to use both illuminations at the same time 8 7 Black white stage plate OS SZ1 OS SZ2 You can use a black white contrast disc to increase the contrast of th...

Page 16: ...ing the horizontal arm 1 Loosen the horizontal arm fixing knob and rotate the arm then tighten again the fixing knob Fig 38 NOTE 180 rotation of the microscope with respect to the base could cause a r...

Page 17: ...Fig 40 Tilting the head holder 1 Loosen the knob Fig 41 on the right side of the head holder The tilting pillar can be moved Once the desired angle is achieved tighten the knob again Swivel the head...

Page 18: ...hten again the knob Fig 44 NOTE 180 rotation of the microscope with respect to the base could cause a rollover of the entire system F Fig 43 ig 43 F Fig 44 ig 44 8 10 Use of Ringlight Illuminator 1 Us...

Page 19: ...ecific camera Instruction manual for detailed explanation about microphotography procedure Instruction manual can be downloaded from this link https www optikamicroscopes com optikamicroscopes down lo...

Page 20: ...of your region matches with the operation voltage of the equipment and that the lamp switch is in off position Users should observe all safety regulations of the region The equipment has acquired the...

Page 21: ...ent collar is too tight Loosen the tension adjustment collar The focus is unstable The tension adjustment collar is too loose Tighten the tension adjustment collar III Electric Section The LED doesn t...

Page 22: ...te The separate collection of this equipment at the end of its lifetime is organized and managed by the producer The user will have to contact the manufacturer and follow the rules that he adopted for...

Page 23: ......

Page 24: ...Ver 1 0 2021 Serie OPTISTAR di OPTIKA MANUALE DI ISTRUZIONI Modello OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 25: ...7 1 6 Connettere il cavo di alimentazione 30 7 2 OS SZ3 OS SZ4 30 7 3 OS SZ5 OS SZ6 33 7 4 Installare l illuminatore Anulare OS SZ3 OS SZ6 35 8 Uso del microscopio 36 8 1 Regolazione della distanza in...

Page 26: ...mportante attenersi alle seguenti istruzioni e leggere il manuale in tutte le sue parti 3 Disimballaggio Il microscopio riposto in un imballo di polistirolo espanso Rimuovere il nastro adesivo dal col...

Page 27: ...OLA ON OFF E REGOLAZIONE INTENSIT LUCE TRASMESSA COLONNA ILLUMINATORE ANULARE LED BASE SELETTORE ZOOM MESSA A FUOCO MOLLETTINE INTERRUTTORE MANOPOLA ON OFF E REGOLAZIONE INTENSIT LUCE INCIDENTE ILLUMI...

Page 28: ...ZIONE INTENSIT LUMINOSA ILLUMINATORE LED INTERRUTTORE BASE CORPO MICROSCOPIO OS SZ5 BINOCULARE OS SZ6 TRINOCULARE USCITA FOTO SOLO OS SZ6 OCULARE ANELLO COMPENSAZIONE DIOTTRICA MESSA A FUOCO COLONNA S...

Page 29: ...esiderata serrare la manopola di bloccaggio posta nella parte posteriore del sistema di messa a fuoco Fig 1 7 1 2 Connettere il cavo della luce incidente Inserire lo spinotto del cavo nel connettore p...

Page 30: ...are la vite di fissaggio dell adattatore fotografico rivolta verso destra 3 Stringere le viti di fissaggio 7 2 OS SZ3 OS SZ4 1 Avvitare la colonna alla base Fig 7 2 Avvitare le viti per bloccare la co...

Page 31: ...Inserire il braccio orizzontale e bloccarlo con la vite di fissag gio Fig 10 11 5 Installare il supporto per la testa Svitare la manopola di bloc co ed inserire dall alto il braccio per il supporto de...

Page 32: ...o Fig 13 7 Inserire dal basso il sistema di messa a fuoco serrare la vite di fissaggio ed avvitare nuovamente la manopola di bloc co dal basso Fig 14 15 8 Ripetere i passi da 7 1 3 a 7 1 5 per l insta...

Page 33: ...er bloccare la colonna Fig 17 F Fig 16 ig 16 F Fig 17 ig 17 F Fig 19 ig 19 F Fig 18 ig 18 3 Inserire l anello di prevenzione discesa e fissarlo all altezza desiderata avvitando la manopola di fissaggi...

Page 34: ...Fig 20 6 Installare il sistema di messa a fuoco Svitare la manopola di blocco ed inserire il supporto dal basso nella colonna Al termine riavvitare la manopola di blocco Fig 21 22 7 Ripetere i passi...

Page 35: ...1 Avvitare l anello di fissaggio nella parte inferiore della te sta stereo Fig 23 2 Posizionare l illuminatore sull anello di fissaggio usando le tre viti di bloccaggio Fig 24 3 Connettere lo spinott...

Page 36: ...e di aumentare o diminuire la tensione delle manopole di messa a fuoco evitando una discesa indesiderata del microscopio sotto il suo stesso peso Regolare la tensione appena al di sopra del punto di s...

Page 37: ...caso in cui il supporto di messa a fuoco non riuscisse a mettere a fuoco il campione si deve alzare o abbassare tutto il corpo del microscopio L ingrandimento totale si calcola in questo modo Ingrand...

Page 38: ...ri posizionare il disco con la parte bianca rivolta verso l alto 8 8 Uso dell illuminazione OS SZ1 OS SZ2 1 Posizionarel interruttore suONperattivarel alimentazione Fig 34 2 Ruotare la manopola della...

Page 39: ...accio orizzontale 1 Allentare la vite di fissaggio del braccio orizzontale e ruotare il braccio quindi serrare la vite di fissaggio Fig 38 NOTA Una rotazione del microscopio di 180 rispetto alla base...

Page 40: ...0 Inclinare il supporto della testa 1 Allentare la manopola Fig 41 sulla parte destra del supporto La colonna inclinabile pu essere spostata Una volta raggiunto l angolo desiderato serrare la manopola...

Page 41: ...la vite di fissaggio Fig 44 NOTA Una rotazione del microscopio di 180 rispetto alla base potrebbe causare un rovesciamento di tutto il sistema F Fig 43 ig 43 F Fig 44 ig 44 F Fig 45 ig 45 8 10 Uso de...

Page 42: ...uzioni specifico della fotocamera per una spiegazione dettagliata della procedura di micro fotografia Il manuale di istruzioni pu essere scaricato da questo link https www optikamicroscopes com optika...

Page 43: ...ore alla rete elettrica assicurarsi che il voltaggio locale sia idoneo a quello dell apparecchio e che l interruttore della lampada sia posizionato su OFF Attenersi a tutte le precauzioni di sicurezza...

Page 44: ...a tensione troppo stretto Allentare l anello di regolazione della tensione La messa a fuoco instabile L anello di regolazione della tensione troppo allentato Stringere l anello di regolazione della te...

Page 45: ...giun ta a fine vita organizzata e gestita dal produttore L utente che vorr disfarsi della presente apparecchiatura dovr quindi contattare il produttore e seguire il sistema che questo ha adottato per...

Page 46: ......

Page 47: ...Ver 1 0 2021 MANUAL DE INSTRUCCIONES Serie OPTISTAR de OPTIKA Modelo OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 48: ...1 6 Conectar el cable de alimentaci n 53 7 2 OS SZ3 OS SZ4 53 7 3 OS SZ5 OS SZ6 56 7 4 Instalaci n del iluminador Anular OS SZ3 OS SZ6 58 8 Uso del microscopio 59 8 1 Regulaci n de la distancia inter...

Page 49: ...ad y seguridad Por favor siga las siguientes instrucciones y lea ste manual en su totalidad para asegurar la operaci n segura del equipo 3 Desembalaje El microscopio esta embalado dentro de una caja d...

Page 50: ...N ON OFF CONTROL DE INTENSIDAD DE LA LUZ TRANSMITIDA PILAR ILLUMINADOR ANULAR LED BASE MANDO ZOOM MANDO DE ENFOQUE INTERRUPTOR BOT N ON OFF CONTROL DE INTENSIDAD DE LA LUZ INCIDENTE ILUMINADOR LUZ TRA...

Page 51: ...R LED INTERRUPTOR BASE CUERPO MICROSCOPIO OS SZ5 BINOCULAR OS SZ6 TRINOCULAR OCULAR ANILLO DE COMPENSACI N DI PTRICA MANDO DE ENFOQUE PILAR MANDO ZOOM BRAZO HORIZONTAL ANILLO DE PREVENCI N DE CA DAS P...

Page 52: ...or del sistema de enfoque Fig 1 7 1 3 Instalar el cabezal Inserte la cabeza y asegure el tornillo de bloqueo Fig 3 7 1 4 Inserci n de oculares Retire las tapas de polvo del ocular e inserte los ocular...

Page 53: ...tornillo de fijaci n del adaptador de foto mirando hacia la derecha Fig 40 3 Apretar los tornillos de fijaci n 7 1 6 Conectar el cable de alimentaci n Conecte el enchufe de la fuente de alimentaci n a...

Page 54: ...n Fig 9 4 Insertar el brazo horizontal y fijarlo con el tornillo de fijaci n Fig 10 11 5 Instale el soporte de enfoque Desenrosque el bot n de pre venci n e inserte el brazo de soporte de cabeza desd...

Page 55: ...fija ci n Fig 13 7 Inserte el sistema de enfoque desde abajo apriete el tornillo de fijaci n y vuelva a apretar la perilla de bloqueo des de abajo Fig 14 15 8 Repita los pasos 7 1 3 a 7 1 5 para la in...

Page 56: ...llos para bloquear el pilar Fig 17 3 Inserte el anillo de prevenci n de ca das y f jelo a la altura deseada atornillando el pomo de fijaci n Fig 18 4 Insertar el brazo horizontal y bloquearlo con la p...

Page 57: ...te del cabezal Desenrosque el bot n de pre venci n e inserte el reposacabezas desde abajo en el bra zo vertical Bloquee la perilla de fijaci n A continuaci n vuelva a enroscar el bot n de prevenci n F...

Page 58: ...erior del cabe zal Fig 23 2 Coloque el iluminador en el anillo de fijaci n utilizando los tres tornillos de bloqueo Fig 24 3 Conecta el enchufe de la fuente de alimentaci n al conector del iluminador...

Page 59: ...ue 3 Volver a la ampliaci n m s baja el esp cimen estar des enfocado F Fig 26 ig 26 F Fig 27 ig 27 F Fig 29 ig 29 F Fig 28 ig 28 AUMENTAR DISMINUIR 8 2 Enfoque 1 Colocar la muestra a observar en la pl...

Page 60: ...de lentes adicionales 1 Atornille la lente adicional deseada en el cuerpo del microscopio Fig 32 La carrera del adaptador de enfoque no pod a compensar las diferentes distancias de trabajo de los dist...

Page 61: ...oscuras coloque el disco con la parte blanca hacia arriba 8 8 Uso de la iluminaci n OS SZ1 OS SZ2 1 Coloque el interruptor en la posici n ON para encender el aparato Fig 34 2 Gire la perilla de luz t...

Page 62: ...Cambiar el ngulo del cabezal 1 Afloje los tornillos y gire la cabeza al ngulo deseado derecha o izquierda luego apriete el tornillo de fijaci n Fig 37 Girar el brazo horizontal 1 Afloje el tornillo d...

Page 63: ...Inclinar el soporte de la cabeza 1 Aflojar el bot n Fig 41 en el lado derecho del soporte El brazo basculante vertical se puede mover Una vez alcanzado el ngulo deseado apriete el mando Cambiar el ng...

Page 64: ...l tornillo de fijaci n Fig 44 NOTA Girar el microscopio 180 desde la base puede causar que todo el sistema se vuelque 8 10 Uso del iluminador Anular 1 Utilice el interruptor ON OFF para encender los L...

Page 65: ...es espec fico de su c mara para obtener una explicaci n detallada del procedimiento de microfotograf a El manual de instrucciones puede descargarse desde este enlace https www optikamicroscopes com op...

Page 66: ...n de entrada del lugar donde se usa coincide con la tensi n de utilizaci n del microscopio y que el interruptor del iluminador est en la posici n off El usuario debe consultar las normas de seguridad...

Page 67: ...ulaci n de la ten si n El enfoque es inestable El anillo de regulaci n de la tensi n est demasiado flojo Apretar el anillo de regulaci n de la tensi n III Secci n El ctrica El LED no se enciende El in...

Page 68: ...fabricante Por lo tanto el usuario que desee deshacerse de este equipo debe ponerse en contacto con el fabricante y seguir el sistema que ha adoptado para permitir la recogida selectiva del equipo al...

Page 69: ......

Page 70: ...Ver 1 0 2021 MANUEL D UTILISATION S rie OPTISTAR par OPTIKA Mod le OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 71: ...e d alimentation 76 7 2 OS SZ3 OS SZ4 76 7 3 OS SZ5 OS SZ6 79 7 4 Installer l illuminateur Annulaire OS SZ3 OS SZ6 81 8 Utilisation du microscope 82 8 1 Ajuster la distance interpupillaire 82 8 2 Mise...

Page 72: ...de l appareil Suivre les directives ci dessous et lire ce manuel dans son int gralit pour un fonctionnement s r de l instrument 3 D ballage Le microscope est emball dans du polystyr ne expans Enlever...

Page 73: ...UR LED LUMI RE INCIDENTE ILLUMINATEUR LUMI RE TRANSMISE OCULAIRE ANNEAU DE COMPENSATION DIOPTRIQUE PILIER ILLUMINATEUR ANNULAIRE LED BASE CORPS DU MICROSCOPE OS SZ3 BINOCULAIRE OS SZ4 TRINOCULAIRE BOU...

Page 74: ...QUE BOUTON DE MISE AU POINT PILIER BOUTON DE ZOOM ILLUMINATEUR ANNULAIRE LED VIS DE FIXATION ANNEAU DE FIXATION CONNECTEUR POUR L ALIMENTATION BOUTON DE R GLAGE DE L INTENSIT LUMINEUSE ILLUMINATEUR LE...

Page 75: ...du syst me de mise au point Fig 1 7 Assemblage 7 1 3 Installer la t te Ins rer la t te et fixer la vis de blocage Fig 3 7 1 4 Installer les oculaires 1 Retirez les capuchons anti poussi re des porte o...

Page 76: ...photo en veillant laisser la vis de fixation de l adaptateur photo face droite 3 Serrer les vis de fixation 7 1 6 Connecter le c ble d alimentation 1 Brancher le jack de l alimentation la prise situ e...

Page 77: ...Fig 9 4 Ins rer le bras horizontal et le fixer l aide de la vis de fixa tion Fig 10 11 5 Installez le support de t te D vissez le bouton de verrouil lage et ins rez le bras pour le support de mise au...

Page 78: ...xation Fig 13 7 Ins rer le syst me de mise au point par le bas serrer la vis de fixation et resserrer le bouton de verrouillage par le bas Fig 14 15 8 R p tez les tapes 7 1 3 7 1 5 pour l installation...

Page 79: ...r bloquer le pilier Fig 17 3 Ins rez la bague de pr vention de descente et fixez la la hauteur d sir e en vissant le bouton de fixation Fig 18 4 Ins rer le bras horizontal et le fixer l aide de la vis...

Page 80: ...20 6 Installez le syst me de mise au point D visser le bouton de verrouillage et ins rer le support par le bas dans le pilier Ensuite revissez le bouton de verrouillage Fig 21 22 7 R p tez les tapes 7...

Page 81: ...e la t te Fig 23 2 Positionnez l illuminateur sur la bague de fixation en utilisant les trois vis de blocage Fig 24 3 Branchez la fiche de l alimentation lectrique sur le connec teur de l illuminateur...

Page 82: ...la hauteur Fig 27 8 3 R glage de la tension des boutons de mise au point Ce r glage permet d augmenter ou de diminuer la ten sion du bouton en vitant une descente involontaire du corps du microscope...

Page 83: ...pouvait pas compenser les diff rentes distances de travail des diff rents objectifs suppl mentaires Si le support de mise au point ne parvient pas focaliser l chantillon le corps entier du microscope...

Page 84: ...bres placez le disque avec la partie blanche vers le haut 8 8 Utilisation de l illumination OS SZ1 OS SZ2 1 Placez l interrupteur sur ON pour mettre l appareil sous tension Fig 34 1 Tournez le bouton...

Page 85: ...urner le bras horizontal 1 Desserrer la vis de fixation du bras horizontal et tourner le bras puis serrer la vis de fixation Fig 38 REMARQUE Une rotation du microscope de 180 par rapport la base peut...

Page 86: ...ig 40 Incliner le support de t te 1 Desserrez le bouton Fig 41 sur le c t droit du support Le bras basculant vertical peut tre d plac Une fois l angle d sir atteint serrez le bouton Changer l angle de...

Page 87: ...ixation Fig 44 REMARQUE Une rotation du microscope de 180 par rapport la base peut faire basculer l ensemble du syst me 8 10 Utilisation de l illuminateur Annulaire 1 Utilisez l interrupteur ON OFF po...

Page 88: ...e votre appareil photo sp cifique pour une explication d taill e de la proc dure de microphotographie de microfotograf a Le manuel d instruction peut tre t l charg partir de ce lien https www optikami...

Page 89: ...la tension d entr e soit compatible avec celle de l appareil et que l interrupteur de l clairage soit en position arr t L utilisateur devra consulter les normes de s curit s de son pays L appareil in...

Page 90: ...Commande macrom trique dur tourner Le col de r glage de la tension est trop serr Desserrer le col de r glage de la tension Mise au point instable Le col de r glage de la tension est trop desserr Serre...

Page 91: ...u pr sent instrument sera effectu e par le fabricant Par cons quent l utilisateur qui souhaite liminer l appareil devra se mettre en contact avec le fabricant et suivre le syst me que celui ci a adopt...

Page 92: ......

Page 93: ...Ver 1 0 2021 BEDIENUNGSANLEITUNG OPTISTAR Serie von OPTIKA Modell OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 94: ...luss des Netzteils 99 7 2 OS SZ3 OS SZ4 99 7 3 OS SZ5 OS SZ6 102 7 4 Montage der Ringlicht Beleuchtung OS SZ3 OS SZ6 104 8 Verwendung des mikroskops 105 8 1 Einstellen des Augenabstandes 105 8 2 Fokus...

Page 95: ...lle Verantwortung daf r 3 Auspacken Das Mikroskop ist in einer Schachtel aus Styroporschicht enthalten Entfernen Sie das Klebeband von der Schachtel und ffnen Sie mit Vorsicht den oberen Teil ohne Obj...

Page 96: ...RINGLICHT LED BELEUCHTER BASE EIN AUS SCHALTER EIN AUS KNOPF UND AUFLICHTREGELUNG AUFLICHT LED BELEUCHTUNG DURCHLICHT BELEUCHTUNG K RPERMIKROSKOP OS SZ3 BINOKULAR OS SZ4 TRINOKULAR 6 2 OS SZ3 OS SZ4 Z...

Page 97: ...R OS SZ6 TRINOKULAR OKULARE DIOPTRISCHER KOMPENSA TIONSRING 6 3 OS SZ5 OS SZ6 6 4 Ringlicht Beleuchter ST TZE RINGLICHT LED BELEUCHTER ZOOMSCHALTER FOKUSSIERKNOPF HORIZONTALER ARM ST TZE FIXIERKN PFE...

Page 98: ...e des Fokussiersystems fest Fig 1 F Fig 1 ig 1 F Fig 4 ig 4 F Fig 3 ig 3 F Fig 2 ig 2 7 1 2 Anschluss des Auflichtkabels Stecken Sie den Kabelstecker in die Buchse an der Oberseite der St tze Fig 2 7...

Page 99: ...n Sie darauf dass die Befestigungsschraube des Fotoadap ters nach rechts zeigt 3 Ziehen Sie die Befestigungsschrauben an 7 2 OS SZ3 OS SZ4 1 Schrauben Sie die St tze an den Sockel Fig 7 2 Ziehen Sie d...

Page 100: ...ungsknopfes Fig 9 4 Setzen Sie den Horizontalarm ein und sichern Sie ihn mit der Befestigungsschraube Fig 10 11 5 Montieren Sie den Kopfhalter L sen Sie den Verriegelungs knopf und stecken Sie den Arm...

Page 101: ...13 7 Setzen Sie das Fokussiersystem von unten ein ziehen Sie die Befestigungsschraube an und ziehen Sie den Verrie gelungsknopf von unten wieder an Fig 14 15 8 Wiederholen Sie die Schritte von 7 1 3...

Page 102: ...t tze zu sichern Fig 17 F Fig 16 ig 16 F Fig 17 ig 17 F Fig 19 ig 19 F Fig 18 ig 18 3 Setzen Sie den Absturzsicherungsring ein und befestigen Sie ihn in der gew nschten H he durch Aufschrauben des Bef...

Page 103: ...nstallieren Sie das Fokussiersystem L sen Sie den Verrie gelungsknopf und setzen Sie die Halterung von un ten in den Vertikalarm ein Schrauben Sie anschlie end den Verriegelungsknopf wieder auf Fig 21...

Page 104: ...Unterseite des Stereokopfes Fig 23 2 Setzen Sie den Illuminator mit den drei Feststellschrauben auf den Befestigungsring Fig 24 F Fig 23 ig 23 F Fig 24 ig 24 F Fig 25 ig 25 3 Verbinden Sie die Stromve...

Page 105: ...egelungsschraube sichern Fig 27 8 3 Einstellen der Fokusspannung Mit dieser Einstellung k nnen Sie die Spannung der Fokussierkn pfe erh hen oder verringern um ein un erw nschtes Absenken des Mikroskop...

Page 106: ...Zusatzlinsen nicht ausgleichen Wenn die Fokussierhilfe die Probe nicht fokussiert muss das gesamte Geh use des Mikroskops angehoben oder abgesenkt werden Auf diese Weise wird die Gesamtvergr erung be...

Page 107: ...Sie die Scheibe mit dem wei en Teil nach oben 8 8 Verwendung der Beleuchtung OS SZ1 OS SZ2 1 Bewegen Sie den Hauptschalter um die Stromversorgung einzuschalten Fig 34 2 Schalten Sie den Knopf f r das...

Page 108: ...len Arm 1 L sen Sie die Befestigungsschraube des Horizontalarms und drehen Sie den Arm dann ziehen Sie die Befestigungsschraube an Fig 38 HINWEIS Wenn Sie das Mikroskop um 180 von der Basis aus drehen...

Page 109: ...t tze 1 L sen Sie den Knopf Fig 41 auf der rechten Seite des St nders Der vertikale Kipparm kann bewegt werden Sobald der gew nschte Winkel erreicht ist ziehen Sie den Knopf an ndern des Winkels des K...

Page 110: ...stigungsschraube an Fig 44 HINWEIS Wenn Sie das Mikroskop um 180 von der Basis aus drehen kann das gesamte System umkippen 8 10 Verwendung des Ringlicht Beleuchtung 1 Verwenden Sie den ON OFF Schalter...

Page 111: ...zum Mikrofotografieverfahren finden Sie in der Bedienungsanleitung der jeweiligen Kame ra Die Bedienungsanleitung kann ber diesen Link heruntergeladen werden https www optikamicroscopes com optika mi...

Page 112: ...Bevor Sie das Netzkabel anstecken vergewissern Sie sich dass die Spannung f r das Mikroskop geeignet ist und dass der Beleuchtungsschalter sich in position OFF befindet Beachten Sie alle Sicherheitsvo...

Page 113: ...en L sen Sie den Einstellring f r die Spannung Die Fokussierung ist instabil Einstellring zu locker gespannt Ziehen Sie den Einstellring f r die Spannung an III Elektrischer System Die LED leuchtet ni...

Page 114: ...ennte Sammlung von Ger ten die am Ende Ihrer Lebensdauer sind wird vom Hersteller organisiert Der Benutzer der dieses Ger t entsorgen m chtet muss dann Kontakt mit dem Hersteller aufnehmen und der Vor...

Page 115: ......

Page 116: ...Ver 1 0 2021 MANUAL DE INSTRU ES OPTISTAR Por OPTIKA Series Modelo OS SZ1 OS SZ2 OS SZ3 OS SZ4 OS SZ5 OS SZ6...

Page 117: ...sa da de foto OS SZ2 122 7 1 6 Ligar o cabo de alimenta o 122 7 2 OS SZ3 OS SZ4 122 7 3 OS SZ5 OS SZ6 125 7 4 Instalar o iluminador Anular OS SZ3 OS SZ6 127 8 Uso do microsc pio 128 8 1 Ajuste da dist...

Page 118: ...seguran a do instrumento importante respeitar as seguintes instru es e ler completamente o manual 3 Desembalando O microsc pio alojado em um recipiente de isopor moldado Remova a fita da borda do reci...

Page 119: ...IDA PILAR ILUMINADOR ANULAR LED BASE INTERRUPTOR BOT O DE LIGAR DESLI GAR E CONTROLO DA INTENSIDADE DA LUZ INCIDENTE ILUMINADOR LED DE LUZ INCIDENTE ILUMINADOR DE LUZ TRANSMITIDA CORPO DO MICROSC PIO...

Page 120: ...LED INTERRUPTOR BASE CORPO DO MICROSC PIO OS SZ5 BINOCULAR OS SZ6 TRINOCULAR OCULAR ANELLO COMPENSAZIONE DIOTTRICA PILAR ANEL DE PREVEN O DE DESCENSO BOT O DE FIXA O INCLINA O DO BRA O DE SUPORTE BOT...

Page 121: ...a parte posterior do sistema de focagem Fig 1 7 Montagem 7 1 3 Instalar a cabe a Inserir a cabe a e fixar o parafuso de bloqueio Fig 3 7 1 4 Inser o de oculares Remova as tampas de poeira dos porta oc...

Page 122: ...e de deixar o parafuso de fixa o do adaptador da foto virado para a direita Fig 40 3 Aperte os parafusos de fixa o 7 1 6 Ligar o cabo de alimenta o Conecte o plugue da fonte de alimenta o ao conector...

Page 123: ...ixa o Fig 9 4 Inserir o bra o horizontal e fixa lo com o parafuso de fixa o Fig 10 11 5 Instale o suporte da cabe a Desaperte o bot o de bloqueio e insira o bra o para o suporte de focagem a partir de...

Page 124: ...afuso de fixa o Fig 13 7 Insira o sistema de focagem por baixo aperte o parafuso de fixa o e volte a apertar o bot o de bloqueio por baixo Fig 14 15 8 Repetir os passos 7 1 3 a 7 1 5 para a instala o...

Page 125: ...rafusos para bloquear o pilar Fig 17 3 Insira o anel de preven o de descenso e fixe o na altura desejada aparafusando o bot o de fixa o Fig 18 4 Inserir o bra o horizontal e fixa lo com o parafuso de...

Page 126: ...cida Fig 20 6 Instale o sistema de foco Desaperte o bot o de bloqueio e insira o suporte por baixo no bra o vertical Em seguida volte a aparafusar o bot o de bloqueio Fig 21 22 7 Repetir os passos 7 1...

Page 127: ...rte inferior da cabe a Fig 23 2 Posicionar o iluminador sobre o anel de fixa o utilizando os tr s parafusos de bloqueio Fig 24 3 Ligar a ficha da fonte de alimenta o ao conector do ilumi nador Fig 25...

Page 128: ...27 8 3 Ajustar a tens o dos bot es de focagem Este ajuste permite aumentar ou diminuir a tens o dos bot es de focagem evitando uma descida indesejada do microsc pio sob seu pr prio peso Ajuste da ten...

Page 129: ...s v rias lentes adicionais Se o suporte do foco n o conseguir focar a amostra todo o corpo do microsc pio deve ser levantado ou abaixado A amplia o total calculada desta forma Amplia o da ocular Ampli...

Page 130: ...voc estiver olhando para amostras scuras coloque o disco com a parte branca voltada para cima 8 8 Uso de ilumina o OS SZ1 OS SZ2 1 Colocar o interruptor em ON para ligar a corrente Fig 34 2 Rode o bot...

Page 131: ...36 Girar o bra o horizontal 1 Desaperte o parafuso de fixa o do bra o horizontal e rode o bra o depois aperte o parafuso de fixa o Fig 38 NOTA Girar o microsc pio 180 a partir da base pode fazer com...

Page 132: ...0 Inclinar o suporte de cabe a 1 Desaperte o bot o Fig 41 no lado direito do suporte O bra o basculante vertical pode ser movimentado Uma vez alcan ado o ngulo desejado aperte o bot o Modificar o ngul...

Page 133: ...e o parafuso de fixa o Fig 66 NOTA Girar o microsc pio 180 a partir da base pode fazer com que todo o sistema tombe 8 10 Utiliza o do iluminador anular 1 Utilizar o interruptor ON OFF para ligar os LE...

Page 134: ...es espec fico da c mara para uma explica o detalhada sobre o procedimento de mi crofotografia O manual de instru es pode ser descarregado a partir desta liga o https www optikamicroscopes com optikami...

Page 135: ...tens o local seja adequada do aparelho e que o interruptor da l mpada esteja posicionado no off Seguir todas as precau es de seguran a da zona na qual se trabalha O aparelho aprovado segundo as normas...

Page 136: ...tra plana sobre a pla tina II Sec o Mec nica O bot o do foco macro est dif cil de rodar O anel de ajuste da tens o est muito apertado Solte o anel de ajuste da tens o O foco inst vel O anel do ajuste...

Page 137: ...dos outros res duos A recolha separada deste equipamento no final da sua vida til organizada e gerida pelo produtor O utilizador ter de contactar o fabricante e seguir as regras que adoptou para a rec...

Page 138: ......

Reviews: