Should the installer or owner be unfamiliar

with the correct installation or operation of

this type of equipment you should contact

the distributor/manufacturer for the

correct advice before proceeding with the

installation or operation of the product.

An earth leakage or residual

current protection device must be fitted to

all installations.

Owner’s Manual

Содержание Whispair 120

Страница 1: ...owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of the product An earth leakage or residual current protection device must be fitted to all installations Owner s Manual ...

Страница 2: ...bility value for money and technological innovation You will find Onga product wherever people need to move water in 3 broad markets covering Technologically advanced solutions for moving and treating water in the Home Garden Pool and Spa Innovative Stock and Crop water management solutions for Primary Industries Water movement products for Building services Emergency services and Original Equipme...

Страница 3: ... that is acceptable Our commitment to quality is reinforced with our ISO 9001 2000 accreditation 3 A Fair Price Onga products are neither the cheapest nor the most expensive in their field Our products do on the other hand always represent very good value for money they always have and they always will 4 Our Team of Dealers The hand picked authorised Onga dealer network throughout Australia and wo...

Страница 4: ...tings of Unplasticized Polyvinyl Chloride PVC U Chlorinated Polyvinyl Chloride PVC C or Acrylonitrile Butadiene Styrene ABS with Plain Sockets for Pipes Under Pressure The outlet socket has been designed to suit the 50mm nominal O D pipe in this standard Minimum Ventilation Area 50 sq cm free space around Blower in accordance with AS NZS 2023 1995 Maximum Ambient Temperature 550 C Electrical Appro...

Страница 5: ...om the potential for water to enter the blower outlet as failure may occur For longer product life Onga recommends the use of a weather proof protective housing for outdoor installations The protective housing should extend below the blower air intake by at least 150mm and provide adequate ventilation BLOWER APPLICATION Your Onga Spa Blower is designed for use with air management systems in reside...

Страница 6: ... not to overtighten Fix blower to mounting frame or base Insert the blower power lead into a correctly rated wall socket Allow adequate access for servicing blower piping AIRSWITCH MODELS A roll of 6 metre air tube is supplied Australia New Zealand models only attach one end of the tube onto the nipple of the air button fitted on the spa bath attach the other end of the air line onto the blower re...

Страница 7: ... 3 Check Airjet caps are clean and free of debris such as tile grout and plaster 4 Fill spa with water and check Airjet connections for leaks which may have developed as a result of transit or handling damage Manual Version Your Onga Whispair may be operated directly from your power outlet or alternatively from a touchpad controller fitted by your spa provider Airswitch Version Ensure power outlet...

Страница 8: ...tely every 30 seconds 2 Your choice of air flow can be obtained by simply pressing the designated air button a second time when the air flow is at your preferred setting 3 Press the designated air button a third time to stop the WhispairPlus The inbuilt technology returns the settings to the start sequence again Sanitation Spa bath versions only Your WhispairPlus has been programmed to aid hygiene...

Страница 9: ... be cool air remaining in the air tubes Extended periods of operation may reduce the bathwater temperature We recommend the use of an Onga HOT pump in conjunction with dual hydro air systems Automatic Timer The WhispairPlus has an in built automatic timer that switches the blower off after 30 minutes of operation to prevent unnecessary nuisance wear and tear on the product When the automatic timer...

Страница 10: ...to operation WhispairPlus vari speed sanitised models The WhispairPlus has an in built red LED that communicates several fault conditions The LED is located within the left hand air intake viewed from the pipe connection end When lit the LED can be viewed through the foam filter pad or more brightly beneath the filter pad A solid light indicates worn motor brushes requiring the complete purchase o...

Страница 11: ...d where our locator service will direct you to your nearest sales stockist or service agent Please be aware that a service fee will be applicable if a fault occurs other than that as described in the product guarantee as being due to defects in materials or faulty manufacture Blower service should be performed by suitably qualified personnel Always unplug power lead prior to service to prevent per...

Страница 12: ...p the pulse of air that operates the micro switch inside the spa blower In built thermal overload blown Check ventilation requirements Ensure air intake is free of debris Call your nearest Onga service agent for a replacement Damaged power cord Turn of power at switch inspect full length of cord for kinks abrasions etc Cord is not field serviceable Cord must be replaced by manufacturer or service ...

Страница 13: ... physiological response to a hot massage spa depends on your age health and medical history If you develop a headache or become dizzy or nauseous get out of the spa at once and cool off under the shower Seek medical assistance if the symptoms persist Consult your doctor or physician before you use the spa for physical therapy of an injury or disorder Do not take a spa without your doctor s consent...

Страница 14: ...14 Item Description Quantity 1 Lead Power 1 2 Airswitch Assembly 1 3 Motor blower 1 4 Hose Clamp 1 5 Air Tube 1 6 Filter Pads 2 Model and serial number of blowers must be given when ordering spare parts ...

Страница 15: ...se 2 Where this Onga product is sold for commercial application as defined in the relevant Trade Practices and Consumer Protection legislation the warranty shall be for a period of three months from the date of purchase by the end user Who the warranty protects This warranty is valid only for the consumer purchaser What the warranty does not cover 1 Damage deterioration or malfunction resulting fr...

Страница 16: ...due to abuse fair wear tear misuse or improper installation will be charged to the owner at the service agents current servicing hourly rate Limitation of implied warranties THERE ARE NO WARRANTIES EXPRESSED OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Exclusion of damages ONGA S LIABILITY IS ...

Страница 17: ...RTANT Please attach your sales invoice docket here as proof of purchase should warranty service be required Please do not return Warranty Retain for your records Purchased From Purchase Date Serial No Model No ...

Страница 18: ...18 L300039C 1004 ...