10 HP

Direct Drive

Dust Collectors

Owner’s Manual

9_11

Oneida Air Systems, Inc.  1001 West Fayette St., Syracuse, NY 13204

Phone 1.800.732.4065  315.476.5151  Fax 315.476.5044  www.oneida-air.com

ZBM000017

Содержание XXK100300

Страница 1: ...10 HP Direct Drive Dust Collectors Owner s Manual 9_11 Oneida Air Systems Inc 1001 West Fayette St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com ZBM000017...

Страница 2: ...ner s Manual before installing or operating system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII 2 3 4 5 6 7 8 9 9 10 11 12 13 14 15 16 17 18 20 System Start Up In...

Страница 3: ...for destroyed motors The Dust Collector Fan Blower is heavy Handling and installation should always be performed by experienced and trained personnel who have experience with rotary equipment In addi...

Страница 4: ...070000 3 Cyclone Cone SCX070000 4 Bolts 3 8 16 x 1 16 AFS015100 Washers 3 8 32 AFW190000 3 8 Wiz Lock Nuts 16 AFT000004 5 16 Wiz Lock Nuts 16 AFT155175 5 Neoprene Gasket 30 RGZ000000 6 Owner s Manual...

Страница 5: ...7 Welded Carbon Steel Cyclone Inlet 12 TEFC 60 Hz Motor Single Phase Insulation Class F4 Voltage 208 230 460 3 Phase Amperage 26 2 23 8 11 9 Made in U S A 3 Pleated Cartridge 390 Sq Ft Spun Bonded pol...

Страница 6: ...10hp Direct Drive O A S 2010 5 IV Dimensions For minimum mounting heights with 55 gal drum 115 9...

Страница 7: ...10hp Direct Drive O A S 2010 6 V Angle Iron Stand...

Страница 8: ...10hp Direct Drive O A S 2010 7 VI Assembly Instructions...

Страница 9: ...ctor and to lid of dust bin Securely fas ten hose clamps There must be an air tight seal between the collector and dust bin 6 Make sure the dust bin lid sits se curely and the rubber gasket on the bin...

Страница 10: ...by the National Electrical Code and local codes Recommended use is 125 of full load amps as shown on the nameplate for motors with 40 degrees celsius ambient and a service factor over 1 0 Recommended...

Страница 11: ...e in the general area Keep air nozzle at least 6 from filter Closer blasts may dam age material This operation should be done with filter on the unit Dust is trapped inside filter so it will not make...

Страница 12: ...nnections For counter clockwise rotation looking from top of motor down Wiring should always be done by a licensed electrician To reverse rotation interchange any two line leads Check rotation after w...

Страница 13: ...widths will vary depending on dust container 2 Hoppers Large capacity hoppers from 5 cu yd to 3 cu yd 3 15 reinforcing angle for added support 3 16 plate body is 100 continu ously MIG welded on inside...

Страница 14: ...leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe too small...

Страница 15: ...nute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in NFPA Code...

Страница 16: ...THE USE OF OUR PRODUCT Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal State Local OSHA NFPA and any other applicable co...

Страница 17: ...the port labeled high on the back of the pressure gauge 5 Make sure the tubing is not crushed or kinked along its entire length cut shorter if necessary 1 Gauge may need to be zeroed Follow the instru...

Страница 18: ...10hp Direct Drive O A S 2010 17 XVI Fan Motor Lubrication Per Baldor specifications their 2 pole motors 3600 RPM motors are to be relubricated every 5500 hours...

Страница 19: ...d in 1 phase it requires a jumper wire that connects T2 and L3 See attached wiring diagram This tricks the overload into thinking it has 3 phase power This jumper must be installed by a licensed elect...

Страница 20: ...ers may desire an alternative Contactor Coil voltage to connect a Starter to a low voltage control circuit Most OAS starters are shipped with 240v coils Plug the Start Stop Push Button Assembly into k...

Страница 21: ...r article 430 32 of the NEC NFPA 70 Install this Jumper for Single O Using the Same Gauge Wire Sized Connected to L1 L2 Omit this Wire for Single O T2 T2 T2 L2 L2 T3 T3 T3 14 22 A2 L3 L3 Reset Yellow...