background image

Oneida Air Systems, Inc.  1001 West Fayette St., Syracuse, NY 13204

Phone 1.800.732.4065  315.476.5151  Fax 315.476.5044  www.oneida-air.com

Shown with

optional Stand.

Models may vary slightly 

in appearance.

9_11

Super Gorilla Owner’s Manual

2 / 2.5 / 3 & 5hp

Содержание Dust Gorilla Pro Smart Boost XGK050105H

Страница 1: ...c 1001 West Fayette St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Shown with optional Stand Models may vary slightly in appearance 9_11 Super Gorilla Owner...

Страница 2: ...g system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII XVIII XIX 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 System Start Up Information Commercial Configu...

Страница 3: ...ructions as well as the recommended safety practices in this manual 3 Motor is pre wired at the factory If magnetic starter trips circuit check the following 1 Dust drum securely fastened to discharge...

Страница 4: ...r Silencer Included with Filter Caution Cartridge Filter Media Pat Pend Flame Guard Arrestor If exhaust air is vented outside you must provide make up return air Flue gases carbon monoxide can be draw...

Страница 5: ...re Pat Pend Flame Guard Arrestor With Standard Silencer Filter 2hp 75 78 dBA 10 2 5 3 5hp 79 82 dBA 10 35 Gallon Fiber Drum Other Sizes Types Available Cast Aluminum Alloy 356 51 Backward Inclined Non...

Страница 6: ...mensions For Minimum Mounting Heights w 39 Filter Dimensions subject to slight variation in manufacturing 6 13 00 2hp 18 00 2 5 5hp 49 53 13 00 2hp 18 00 2 5 5hp 8 00 3 5hp 2 2 5hp 2 2 5hp 92 00 3hp 9...

Страница 7: ...lips 8 5 16 Bolts 5g 1a 2hp motor BMZ020105 2 5hp BMZ025105 3hp motor BMZ030170 5hp BMZ050170 1 Motor Assembly 2hp BXI002105 2 5hp BXI002505 3hp BXI012105 5hp BXI002305 5b J Hooks 8 AFJ051602 AFT00000...

Страница 8: ...the clip is on the INSIDE of the Fan Housing as shown in diagram 2 Stick the gasket material around the Fan Housing as shown in the diagrams outside of the bolt circle Making sure of a complete seal D...

Страница 9: ...ire unit up onto stand Unit is extremely heavy and top weighted be advised Bolt Fan Blower housing to Cyclone barrel Then bolt Motor and Plate to Fan Blower housing Put Cone up on stand and orient hol...

Страница 10: ...tion of outlet If rotation you desire does not correspond to an existing hole in Angle Ring drill new ones Use three 3 8 bolts included with washers lock washers to secure the fan See Fig 4 5 Attach t...

Страница 11: ...hiz nut making sure the support hanger on the Plenum is at the bottom 3 Attach gasket around cut out in filter plate as shown in diagram making sure there are no gaps where ends meet 4 Attach filter p...

Страница 12: ...ct cyclone and dust bin Make sure dust bin is in place and ductwork is connected to inlet before turning on the dust collector Electrical Wiring Make sure power source matches wire voltage configurati...

Страница 13: ...p air nozzle at least 6 from filter Closer blasts may damage material This operation should be done with filter on the unit Dust is trapped inside filter so it will not make a mess 6 Filter must be cl...

Страница 14: ...the factory and need only be plugged into a NEMA 6020R dedicated electrical recepyacle Optional Remote Controller diagram pg 19 Starter will not operate at any other voltages SFA 12 1 FLA 11 5 Baldor...

Страница 15: ...k for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe...

Страница 16: ...eet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in...

Страница 17: ...ISING FROM THE USE OF OUR PRODUCT Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal State Local OSHA NFPA and any other app...

Страница 18: ...inside of Mid Gussets with 2 1 4 20 x 3 4 bolts and secure with 1 4 Flat Washer and 1 4 20 Nylock Nut Adjust the legs for the 21 or 23 cone by positioning the bolts in the appropriate position in the...

Страница 19: ...re on the outside surface of the plastic bag that keeps it pulled tight against the sides of the dust drum Can be used with 35 and 55 gal barrels Must be wired into your system Liner makes for easy em...

Страница 20: ...19 Combined Super Gorilla Owner s Manual O A S 2010 XVII Fan Motor Maintenance Per Baldor specifications their 2 pole motors 3600 RPM motors are to be relubricated every 5500 hours...

Страница 21: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Страница 22: ...to stand user must drill a hole and supply hardware attachment Connect clear tubing from brass static pressure tube to port labeled on the back of the pressure gauge Make sure tubing is not crushed or...