manualshive.com logo in svg
background image

 

 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 1 of 9

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ High Performance Keypad

 

IS-0369 REV. D

 

  ©Copyright 2009 by On-Q/Legrand All Rights Reserved. 

1.   Introduction  

 

The lyriQ™ High Performance Keypad, P/N AU1000-xx 

(see 

Figure 1

),

 is an 

integral part of the lyriQ™ Multi-Room Audio System. It is a component which, 
when combined with other essential components ( a Source Input Unit, 
Distribution Module and Speakers) and your source equipment (receiver, CD 
player, etc.), creates a versatile whole-house audio system that will fill your 
rooms with high-quality sound for years to come. It uses Category 5 wiring to 
distribute audio signals, control information and IR for remote control. The High 
Performance Keypad has on-board 20 Watt per channel class D amplifiers to 
provide a rich level of clean sound even in outdoor or large room applications. 
It also contains a full set of features, including the ability to control all other 
keypad volume controls in the house. Build a system that accommodates the 
needs of any space by combining the lyriQ™ High Performance Keypad with 
the lyriQ™ Standard Keypad (P/N AU7394-xx) in the same system. The 
AU1000-xx is available in white (-WH), light almond (-LA), ivory (-IV), or black 
(-BK). 

 

2.   Description  

 

The front panel of the lyriQ™ High Performance Keypad, PN AU1000-xx 

(see 

Figure 1

),

 looks almost identical to the lyriQ™ Standard Keypad (AU7394-xx). It 

also has push buttons for VOLUME UP/DOWN (with five associated green 
Volume Bar Graph LEDs), SOURCE (with four green Source Selection LEDs) 
and MUTE (with one red status LED). There is also an IR target window and tri-
colored status LED. The visual cue from the front panel that this is a High 
Performance Volume Control are the parenthesis surrounding the music note in 
the lower right hand corner. 
 

NOTE: lyriQ™ Keypads are recommended for indoor use only. 

 
On the rear of the lyriQ™ High Performance Keypad (see 

Figure 2

) the Category 

5 connection is an RJ45 jack (J1). The TB2 speaker output connections (left and 
right, plus and minus) are spring loaded and designed to support up to 14 gauge 
wire. The TB3 Line Out connections (plus and minus) are also spring loaded and 
designed to support up to 14 gauge wire. This mono-summed output is designed 
for powered sub-woofers and as such is filtered through an 80Hz low pass filter. 
The other terminal block on the rear (TB1) is used for powering the keypad. Up to 
14 gauge speaker wire may be used for this purpose, and this speaker wire (two 
conductor or four conductor) is run from a power distribution module (P/N 
AU1001) in the enclosure to the ketpad. We recommend 16/4 speaker wire, 
since it is available paired with Category 5 from a variety of sources. Again, the 
TB1 connections are spring loaded (plus and minus) with the two plus 
connections on the red portion of TB1 and the two minus connections on the 
black portion of TB1. For ease of installation, connect the red wire and white wire 
to the red (plus) portion of TB1 and the black and green wire to the black (minus) 
portion of TB1.  

Figure 1 

Figure 2 

Содержание IS-0369 REV. D

Страница 1: ...AU7394 xx It also has push buttons for VOLUME UP DOWN with five associated green Volume Bar Graph LEDs SOURCE with four green Source Selection LEDs and MUTE with one red status LED There is also an IR target window and tri colored status LED The visual cue from the front panel that this is a High Performance Volume Control are the parenthesis surrounding the music note in the lower right hand corn...

Страница 2: ...g outlet box or mud ring at each Volume Control location B Trim out steps 1 Connect the volume control by terminating the pre wired Category 5 cable from the enclosure with an RJ45 plug following the T568A wiring standard and insert this plug into jack J1 see Figure 2 2 For the power connection TB1 strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the...

Страница 3: ...n to each volume control location strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the red plus portion of TB1 Insert the stripped black and green wires into the black minus portion of TB1 NOTE As noted before Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus That wiring will also work as long ...

Страница 4: ...rformance Keypad IS 0369 REV D Copyright 2009 by On Q Legrand All Rights Reserved 5 Keypad Mounting check all connections and test the system s operation before installing the volume controls into the wall Use the included screws to install the volume control and wall plate into the single gang box NOTE A 20 in or greater single gang box is recommended Figure 4 ...

Страница 5: ...OWN button to adjust back light level Press SOURCE or MUTE button to exit or wait for 10 second time out see Figure 5 NOTE When any Keypad button is tapped back light level goes to full bright and returns to the adjusted level when activity ceases For Remote operation the back light goes to full bright when an IR command is received and returns to the adjusted level when activity ceases F Temporar...

Страница 6: ...e Source Control mode and press the SOURCE button it will cause everyone to go to 4 and then 1 and then 2 and finally to 3 while double tapping it will cause every active keypad to go directly to Source 3 NOTE The Whole House Source Control mode will be exited when the user fails to press a key within 5 seconds or by pressing and holding the MUTE and SOURCE buttons simultaneously as before 5 Impor...

Страница 7: ... to be controlled from other keypads on the system that have engaged Whole House Mode Whole House Disable src 1 vol 2 turns off the ability of a keypad to be controlled by other keypads that have engaged Whole House Mode Will not respond to audio interrupt Will still be able to implement a Whole House command from keypad Keypads connected to systems with the Integration Module will not be controll...

Страница 8: ... radiated interference Grouping Studio Keypads Only Default src 1 3 vol 1 Keypad is not grouped Keypads not on a system with the Integration Module should be set to the default setting Keypads with Integration Module on system will provide information to the Integration Module to be displayed for the end user Member of a Group src 1 3 vol 2 Keypad will not provide information to the Integration Mo...

Страница 9: ...1 IR Carrier Frequency at 56kHz src 1 4 vol 3 Default is used for normal operation and environments The default will be effective for the vast majority of source devices Carrier frequency can be changed if end user s source device does not respond to multi burst IR Carrier Frequency Adjustments are chosen based on end user s remotes Most devices are 40kHz Cable and satellite boxes are often 56kHz ...

Отзывы: