General Purpose Mixers

Instruction Manual

Version 1.2

1-800-465-0234

www.omcan.com

3115 Pepper Mill Court, Mississauga, ON, L5L 4X5

4450 Witmer Industrial Estates, Unit 4, Niagara Falls, NY, 14305

Summary of Contents for SP200A

Page 1: ...General Purpose Mixers Instruction Manual Version 1 2 1 800 465 0234 www omcan com 3115 Pepper Mill Court Mississauga ON L5L 4X5 4450 Witmer Industrial Estates Unit 4 Niagara Falls NY 14305...

Page 2: ...ction General Information Technical Specifications Installation Operation Instructions Maintenance Troubleshooting Mixer Capacity Chart Parts Breakdown Electrical Schematics Warranty Registration Mode...

Page 3: ...concealed please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours so we may initiate a claim with the carrier A detailed report on the extent of the damage...

Page 4: ...trical cords on these machines are equipped with a three pronged grounding plug which must be connected to a properly grounded receptacle If the receptacle is not properly grounded contact an electric...

Page 5: ...owl to load position 6 and finally disconnect the power supply Notes The power socket must be provided with a good ground wire to guarantee the mixer is grounded properly There will be an electric sho...

Page 6: ...eatures 1 On Button 2 Off Button 3 Countdown Timer Knob On Off Switch SP200A Features 1 On Button 2 Off Button On Off Switch SP300AT Features 1 Separate On and Off Switches 2 Countdown Timer Knob 3 Sp...

Page 7: ...ated on frame Carefully align holes on the bowl with the studs on the bowl arms Fig 1 2 Once the bowl is seated properly swing the locking levers into position Fig 2 3 To remove the bowl follow the in...

Page 8: ...k in place To Remove the attachment follow the instructions above in reverse order Installing Mixer Attachments SP200AT SP200A Ensure machine is off lower bowl to loading position Open the Guard by pu...

Page 9: ...lifting it up towards the top of the machine until it stops Fig 9 Raise the attachment through the shaft keeping note of where the notch is Fig 7 Guide the notch through the path until it reaches the...

Page 10: ...seal rings are worn out Replace seal rings Motor temperature raises while reduced output speed Too low voltage Check the power supply Over loaded Reduce load The speed of mixing is too high or wrong...

Page 11: ...Thin Pizza 40 max mix time is 5 min Hook 1 N R N R 10 lbs Dough Med Pizza 50 AR Hook 1 N R N R 12 lbs Dough Thick Pizza 60 AR Hook 1 N R 10 lbs 14 lbs Dough Raised Donut 65 AR Hook 1 N R 6 lbs 10 lbs...

Page 12: ...12 Parts Breakdown Model VFM10B 20467...

Page 13: ...1 25074 Oil Seal 14 25104 Roller 42 3 25135 Crank Lever 72 25075 Locking Bolt 15 25105 Spring 42 4 25136 Handle 73 25076 Block Handle 16 25106 Taper Gear Wheel 1 43 25137 Connecting Rod 74 25077 Block...

Page 14: ...14 Parts Breakdown Model SP200A 20441 Model SP200AT 17835...

Page 15: ...Wheel 1 43 24932 Back Housing 74 24867 Speed Handle 14 24900 Gear 44 24933 Back Cover 75 24868 Plug 15 24901 Bushing 45 24934 Handle Shifter 76 24869 Attachment Hub 16 24902 Sleeve 46 24935 Crank Leve...

Page 16: ...16 Parts Breakdown Model SP300A 20442 Model SP300AT 17836...

Page 17: ...24967 Plug Attachment Hub 17 25003 Spacer 50 25039 Green On Button 84 24968 Attachment Hub 18 25004 Nut 51 25040 Red Stop Button Old Style 85 24969 Locking Bolt 19 25005 Base 52 25041 Red Stop Button...

Page 18: ...725rpm 1PH 0 4Kw 1 2 Micro Switch V 152 1C25 250V 10A 2 3 Contact Switch CJX2 0910 Ac110V 60Hz 1 4 Start Button SPL63 250V 10A 1 Green 5 Stop Button SPL63 250V 10A 1 Red 6 Overload Protector Ac125 250...

Page 19: ...z 1725rpm 1PH 1 1Kw 1 2 Micro Switch V 152 1C25 250V 10A 2 3 Contact Switch CN 11 Ac110V 60Hz 1 4 Start Button SPL63 250V 10A 1 Green 5 Stop Button SPL63 250V 10A 1 Red 6 Overload Capacitor Ac125 250V...

Page 20: ...w 1 2 Micro Switch V 152 1C25 250V 10A 2 3 Contact Switch CN 11 Ac110V 60Hz 1 4 Start Button SPL63 250V 10A 1 Green 5 Stop Button SPL63 250V 10A 1 Red 6 Overload Capacitor Ac125 250V 15A 1 KUOYUH 7 St...

Page 21: ...1725rpm 1PH 1 8Kw 1 2 Micro Switch V 152 1C25 250V 10A 2 3 Contact Switch CN 11 Ac110V 60Hz 1 4 Start Button SPL63 250V 10A 1 Green 5 Stop Button SPL63 250V 10A 1 Red 6 Overload Protector Ac125 250V...

Page 22: ...8Kw 1 2 Micro Switch V 152 1C25 250V 10A 2 3 Contact Switch CN 11 Ac110V 60Hz 1 4 Start Button SPL63 250V 10A 1 Green 5 Stop Button SPL63 250V 10A 1 Red 6 Overload Capacitor Ac125 250V 20A 1 KUOYUH 7...

Page 23: ...N 4450 Witmer Industrial Estates Unit 4 Niagara Falls New York USA 14305 www omcan com warrantyregistration html Thank you for choosing Omcan Purchaser s Information Name Company Name Address Telephon...

Page 24: ...ven products Omcan continues to help our customers remain competitive With associates in North America Europe and Asia our global footprint continues to expand as we hold to the principle that clients...