Gas Wok Range

Model CE-CN-WOK NG

Item 47351

Instruction Manual

Revised - 12/09/2021

Toll Free: 1-800-465-0234

Fax: 905-607-0234

Email: [email protected]

www.omcan.com

Summary of Contents for CE-CN-WOK NG

Page 1: ...Gas Wok Range Model CE CN WOK NG Item 47351 Instruction Manual Revised 12 09 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...10 10 11 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Regis...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...rse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor a...

Page 5: ...onent failure or other damages resulting from installation in non commercial or residential applications The right is reserved to deny shipment for residential usage if this occurs you will be notifie...

Page 6: ...th written or electronic communication 3 All original packing materials must be kept for inspection purposes 4 The Wok range can t have been moved installed or modified Remove all packing material and...

Page 7: ...esistive to natural gas This range uses NG56 connections for gas nozzles MANUAL SHUT OFF VALVE This installer supplied valve must be in the gas service line ahead of the appliance regulator in the gas...

Page 8: ...e appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as ap...

Page 9: ...e failure device will shut the gas off If you notice the flame was extinguished please turn the flame control valve to OFF position and re ignite the pilot flame A 5 minutes complete shut off period s...

Page 10: ...impossible to remove Ensure your wok range is checked by a qualified technician once a year for efficient operation of the appliance CONTACT THE APPLIANCE SUPPLIER OR A LOCAL SERVICE COMPANY TO PERFOR...

Page 11: ...equirements Adjust nozzle diameter Not enough air to ignite Increase damper opening degree Gas spikes and floats Turn down valve flow THE PROBLEMS MENTIONED ABOVE ARE FOR REFERENCE ONLY IF ANY FAULT O...

Page 12: ...12 Parts Breakdown Model CE CN WOK NG 47351...

Page 13: ...AI578 Support Beam for 47351 11 AI586 Duck Mouth Burner for 47351 20 AI571 Side Plate Left and Right for 47351 4 AI579 Input Pipe Mount Pad for 47351 12 AI587 Union for 47351 21 AI572 Tray Guide for...

Page 14: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: