background image

Revised - 01/20/2021

Toll Free: 1-800-465-0234

Fax: 905-607-0234

Email: [email protected]

www.omcan.com

Refrigerated Showcase

Model RS-CN-0500

Item 34874

Instruction Manual

Summary of Contents for 34874

Page 1: ...Revised 01 20 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcase Model RS CN 0500 Item 34874 Instruction Manual...

Page 2: ...2 13 14 15 Table of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warra...

Page 3: ...NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRE...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...nspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en...

Page 6: ...d No shared power outlets Refrigerator cable should never share the power outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be used wh...

Page 7: ...12 C 32 53 6 F Max Ambient Temp Rating 32 C 90 F Refrigerant and Injection R404a 320g Rated Current 3 7A Shelf Size 22 6 x 22 575 x 559mm Dimensions 25 6 x 25 6 x 76 6 650 x 650 x 1945mm Weight 297 l...

Page 8: ...the LED flashes 5 Defrost LED During defrosting the LED is on When it stops defrosting the LED is off During the delay of defrost the LED flashed CAUTION Never block the air outlet and suction to keep...

Page 9: ...g pipe for melting water damaged Replace the heating pipe Water level controller failure Replace the water level controller Ambient temperature or humidity beyond standards Improve the conditions Main...

Page 10: ...ion Capillary is blocked by ice Replace the drying filter Temperature controller failure Replace the temperature controller NOTE Following occurrences are not problems The murmur of water is heard whe...

Page 11: ...11 Parts Breakdown Model RS CN 0500 34874...

Page 12: ...30 Door Glass for 34874 23 60946 Air Outlet Cover for 34874 40 60915 Rear Grill for 34874 8 60931 Motor of Evaporator for 34874 24 60947 Door Handle for 34874 41 60916 Light Ceiling for 34874 9 60932...

Page 13: ...13 Electrical Schematics Model RS CN 0500 34874...

Page 14: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...