background image

Instructions

This instruction manual is for the Olympus LED and LDP Light Source.
To ensure safety, obtain optimum performance and to familiarize yourself fully with the use of this 
product, we recommend that you study this manual thoroughly before operating this product, and 
always keep this manual at hand when operating this product.
Retain this instruction manual in an easily accessible place near the work desk for future reference.
For details of products covered by this instruction manual, see page 10.

LED and LDP Light Source

U-LGPS

Optical Microscope Accessory

Summary of Contents for U-LGPS

Page 1: ...oduct we recommend that you study this manual thoroughly before operating this product and always keep this manual at hand when operating this product Retain this instruction manual in an easily accessible place near the work desk for future reference For details of products covered by this instruction manual see page 10 LED and LDP Light Source U LGPS Optical Microscope Accessory ...

Page 2: ...st not be disposed of as unsorted municipal waste but should be collected separately Refer to your local Olympus distributor in EU for return and or collection systems available in your country Research Industrial and In vitro diagnostic medical use Products This product is categorized as FCC Part15 Class A exempt device Using this product may affect other equipment in the environment The operator...

Page 3: ...enclature of main operating portions 10 2 Operating Procedures 11 1 Turning ON the lamp 11 2 Turning OFF the lamp 11 3 Adjusting the brightness 12 4 Pilot lamp color and counter display 12 3 Troubleshooting 13 4 Specifications 14 5 Assembly 15 1 Attaching U LLG150 U LLG300 15 2 Attaching the power cord 16 3 Connecting the USB cable 16 4 Replacing the fuse 17 Contents ...

Page 4: ...ii ...

Page 5: ...OOOOOOOOOOOOO Title in third layer Title in first layer 2 1 1 2 indicates the operating procedure and A B indicates the portion you operate Operating procedure B A The following symbols are used in this instruction manual WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not ...

Page 6: ...use This product includes the following items If any item is missing or damaged contact Olympus U LGPS USB cable Instruction manual for U LGPS this instruction manual This product is used for research industrial and in vitro diagnostic medical purposes in combination with microscopes For details refer to the instruction manual for the microscope system to be combined Intended Use ...

Page 7: ...r the product Otherwise the product may overturn CAUTION Never peel off the warning label CAUTION Warning label position Right side surface of U LGPS This product is specified as CLASS 1 laser product This product complies with 21 CFR 1040 10 and 1040 11 except for conformance with IEC 60825 1 Ed 3 as described in Laser Notice No 56 dated May 8 2019 CLASS 1 LASER PRODUCT IEC60825 1 2007 IEC60825 1...

Page 8: ...d by Olympus U LGPS may not work properly Prevention of electric shock Never disassemble any part of this product It could cause electric shock or failure of the product Be sure to turn OFF the main power of the product and then disconnect the power cord from the power cord connector on the product or from the power outlet before performing maintenance storage or transportation It could cause elec...

Page 9: ... the illumination methods CAUTION Remove the liquid light guide after the liquid light guide and the LDP light source are fully cooled down Otherwise you may get burned CAUTION Liquid Light Guide Do not use the liquid light guide that is not conformed to this product You may get burned or your eyes may be damaged For the liquid light guide that is conformed to this product see page 14 Do not remov...

Page 10: ...F is selected by pressing it to ON or OFF side Indicates that the seesaw type main switch is OFF If caution labels are dirty or peeled off contact Olympus for replacement or inquiries Safety warning symbols Label position and instruction The labels are attached to the portions which require special cautions during use and operation Be sure to follow these instructions Label Label position Instruct...

Page 11: ... of this product It could cause unexpected accidents or failure of the product Do not use the product in areas where it may be subjected to direct sunlight high temperature and or humidity dust or vibrations Do not use or store this product in environments where it may be subjected to dust strong electric field strong magnetic field gas corrosion chlorine acid alkali etc and in sudden environmenta...

Page 12: ...X10 SZX2 ZB10 SZX16 SZX2 ZB16 SZX2 ZB16A SZX7 SZX ZB7 BX51WI BX51WIF BX53M BX53MRF S BX53MTRF S BXFM BXFM F GX53 GX53F MVX 10 MVX ZB10 MX63 MX63 F MX63L F SpinSR10 IX83P2ZF The use of this product in combination with systems that are not listed in the table shown above cannot be guaranteed If you wish to use this product in combination with systems that are not listed in this table take measures u...

Page 13: ... guide Wipe the product with a dry soft cloth If the dirt cannot be removed by dry wiping moisten a soft cloth with diluted neutral detergent and wipe the dirty surface with it Blow off the dust attached to the edge surface of the liquid light guide with clean air WARNING NOTE TIP After using this product set the main switch of U LGPS to OFF wait until U LGPS is cooled down sufficiently and keep i...

Page 14: ...p switch Liquid light guide insertion port Power cord connector Power switch ON OFF Light intensity adjustment dial Power switch Power cord connector Incidence side connector Clamping screw Emission side connector Liquid light guide insertion port Liquid light guide insertion port Fuse Fuse Pilot lamp Color Status Green Standby Blue ON Red Error Pilot lamp The color of the pilot lamp indicates the...

Page 15: ...lue Pressing the lamp switch C allows you to select ON or OFF of the lamp You can check the status of the lamp by the color of the pilot lamp For details see page 12 2 TIP TIP 1 Turning ON the lamp 2 Turning OFF the lamp A A C D Set the power switch A to OFF The pilot lamp B on the front of U LGPS turns OFF The numeral characters or texts on the counter D on the front of U LGPS disappear When usin...

Page 16: ...d as follows 4 Pilot lamp color and counter display D B Pilot lamp B Display on counter D Color Status Display Description Green Lamp is OFF 010 100 Brightness of the lamp when the lamp is ON Blue Lamp is ON Red Error in U LGPS Lamp turns OFF automatically c01 c23 Details of the error in U LGPS When using U LGPS control software The color of the pilot lamp B changes as the table shown above and th...

Page 17: ...s in the light path of the microscope frame Remove the shutter from the light path For details refer to the instruction manual for the microscope frame you use The lamp is too dark The liquid light guide is not attached to the U LLGAD properly Or U LLGAD is not attached to the illuminator of the microscope frame properly Connect them properly 15 The lamp does not turn ON The pilot lamp is green Pr...

Page 18: ...time of light source 25 000 hours or more nominal time Condition specified by Olympus Conformable liquid light guide U LLG150 U LLG300 Operating environment Indoor use Altitude Max 2000 meters Ambient temperature 5 to 40 C 41 to 104 F Relative humidity Max 80 31 C 88 F or less without condensation In case of over 31 C 88 F the relative humidity in operating environment is decreased linearly throug...

Page 19: ...ly excessive force 6 7 WARNING NOTE Loosen the clamping screws B C of U LLGAD using the Allen screwdriver provided with the microscope If the clamping screws B C are not fully loosened the tip of the emission side connector D contacts the clamping screws B C and the emission side connector may not be inserted to the correct position Insert the emission side connector D of U LLG150 U LLG300 complet...

Page 20: ...tended by Olympus cannot be assured Be careful not to apply excessive force to power cords Be sure to set the main switch to OFF before connecting the power cord Insert the power cord completely to the end of the connector on the back of U LGPS CAUTION NOTE 1 1 2 Attaching the power cord 2 Insert the power cord plug completely to the end of the power outlet 2 The USB cable is connected when using ...

Page 21: ...ce the fuse in the fuse box with a new fuse Applicable fuse T 3 15 A H 250 V LITTELFUSE 02153 15MXP Using a non specified fuse may cause a fire Return the fuse box to the original position and rotate the fuse box B using the flat blade screwdriver to secure it If the fuse is blown out frequently contact Olympus for assistance 1 2 3 WARNING 4 TIP 4 Replacing the fuse A B ...

Page 22: ...ally the power supply cord which is approved by one of the agencies mentioned in Table 1 please use replacements approved by any other equivalent and authorized agencies in your country Country Agency Certification mark Country Agency Certification mark Argentina IRAM Italy IMQ Australia SAA Japan JET Austria ÖVE Netherlands KEMA Belgium CEBEC Norway NEMKO Canada CSA Spain AEE Denmark DEMKO Sweden...

Page 23: ...ric Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 Österreichischer Verband für Elektrotechnik ÖVE ÖVE HAR 30 10 50 Danmarks Elektriske Materialkontroll DEMKO DEMKO HAR 30 10 30 National Standards Authority of Ireland NSAI NSAI HAR 30 30 50 Norges Elektriske Materiellkontroll NEMKO NEMKO HAR 10 10 70 Asociaci...

Page 24: ...Distributed by Manufactured by Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com AM5103 01 Issued in September 2020 ...

Reviews: