background image

Arc-H-User-Manual-Universal-2020 (LD)-v3

OE GmbH

www.oeelectrics.de

+49 (0)2261 958 3001

[email protected]

OE Head Office

www.oeelectrics.co.uk

+44 (0) 1924 367255

[email protected]

www.oeelsafe.com.au

+61 2 9454 7500

[email protected]

Slow on/off Blue -  Device is on and in stand-by mode

Solid Blue - Device is on and in charging mode.

Red - Error Mode:

• 

Phone not aligned with charging coil under ARC 

logo - Align phone

• 

Foreign Object Detected - Remove metal from 
near charger.

• 

Phone is too close - Move phone greater than 
20mm (0.78”) away.

• 

Power Adapter Issue - Only use original plug pack.

• 

NON-Compatible Phone - Upgrade phone.

LED Functions:

 The phone will not charge when I place the phone 

directly on the charger, to check it works before 

installation?
The charger will not charge a phone unless it is 
separated (and aligned) from the phone by at least 

20mm(0.78”).

The magnets will not attract each other through my 

desk?
The magnets only work up to 25mm(1”). Either route 
the desk underside to <25mm (1”) thick or call to 
purchase the Electronic Alignment Guide.

Precautions

Through Surface Wireless Charging

ADVANCED RESONANT CHARGER

OE Inc
www.oeelectrics.com
+1 (844)-927-0600
[email protected]

• 

Follow installation guidelines overleaf for optimum 
charge.

• 

Keep metal objects (keys, coins, credit cards etc) 
away from charging area. They may activate foreign 
object detection (FOD) and ARC-H will not operate.

• 

Do not use phone cases with magnet or metallic 
blocks when charging.

• 

Charger will only charge through non-metallic 
surfaces.

• 

Install further than 35mm from metal objects.

• 

Do not expose ARC-H to liquids.

• 

Use only supplied 19V power supply with correct plug 
attachment for country of use.

• 

Complies with the following Safety and EMC 
standards.

The ARC logo identifies the 
coil center which must be 
aligned with the Resonator 
Pad

Pad fitted over the centre of 
the charger - WILL NOT WORK

The charging coil is Off-
Center, the alignment guide 
MUST be used to guarantee 
accuracy

Pad misaligned - WILL NOT 
WORK

The alignment guide MUST be 
used to guarantee accuracy

LD

Alignment

Common Faults & Troubleshooting

Is the table too thin or too thick?
ARC-H (LD) is designed for worksurfaces with surfaces 
20-50mm (0.78”-2”) thick
FCC requirements in USA limit the maximum worksurface 
thickness to 30mm (1.18”).

Will my device charge with metal objects on the 

charging surface?
Devices won’t charge if there’s a metal object on the 
charging surface. Remove the object and allow several 
seconds for the device to begin charging again.

Can ARC-H charge other wireless charging devices?
Due to the coils size, ARC-H will only charge your 
compatible mobile phones.

My phone isn’t charging or is charging slowly.
Generally the wireless charging coil is located in the 
middle of a phone, so please make sure your phone is 
placed over the center of the resontor pad. If the phone 
case is too thick or has metal/magnetic accessories, 
your phone may not charge.

Standards

• 

Qi Compatible

• 

FCC part 15 (when installed under surfaces 20-30mm 
(0.78”-1.18”) thick)

• 

IEC62386-1:2014 +A11:2017

• 

EN50655:2017

• 

ETSI EN 301 489-1 V2.2.3 (2019-11)

• 

ETSI EN 301 489-3 V2.1.1 (2019-03)

• 

ETSI EN 303 417 V1.1.1 (2017-09)

FCC Statement

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 
(1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including 
interference that may cause undesired operation.

Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment.

NOTE: This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to part 15 of 
the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential 
installation. This equipment generates uses and can radiate radio 
frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
- Reorient or relocate the receiving antenna. 
- Increase the separation between the equipment and receiver. 
- Connect the equipment into an outlet on a circuit different from 
that to which the receiver is connected. 
- Consult the dealer or an experienced radio/TV technician for 
help 
 
RF Exposure Warning Statements: 
This equipment complies with FCC radiation exposure limits set 
forth for an uncontrolled environment. This equipment shall be 
installed and operated with minimum distance 20cm between 
the radiator & body.

Reviews: