background image

PRODUCT IMAGE

Oceanic Ltd, Pountney Street, Wolverhampton, WV2 4HX

Phone: 01902 450 550  

[email protected]   www.oceanic-saunas.co.uk

Sauna & Steam

STEAM GENERATOR

(Domestic & Light Commercial) 

Assembly and operating manual

21.02.18

Summary of Contents for OC-105 S

Page 1: ...Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam STEAM GENERATOR Domestic Light Commercial Assembly and operating m...

Page 2: ...e 2 OC A Controller Parameters 8 5 7 Temperature Sensor Parameters 8 6 OC A Controller Description 9 7 Installation 10 7 1 Generator Size 10 7 2 Steam Generator Location 11 7 3 Water and Steam Connect...

Page 3: ...your steam generator 1 or 3 phase For hard water areas please read our descaling section on page Water supply must have maximum of 1 bar pressure recommend the use of a pressure reducing valve if nec...

Page 4: ...omestic OC 40 4 17A 390 190 335 1 2 1 2 1 2 White OC 60 6 26A 8 6A 390 190 335 1 2 1 2 1 2 White OC 80 8 35A 11 6A 450 190 353 3 4 1 2 1 2 Chrome Steam On Demand OC 60 S 6 26 8 6 390 190 335 15 1 2 1...

Page 5: ...rol two or more steam generators e g if you need a 24KW steam generator you can use one OC A controller to control two 12kw steam generator or three 10kw steam generators Temperature sensor OC A contr...

Page 6: ...45 72 60 OC 80 90 450 195 353 35 135 45 72 60 OC 10 120 390 206 353 25 135 45 77 60 5 2 Steam Generator Frame Sizes 5 3 Clearance distances 5 4 Ventilation Ensure air flow into area where steam gener...

Page 7: ...Boiler 6 Insulation material Reduce the loss of the boiler heat 7 Water lever probe Detect the water level 8 Steam outlet Steam outlet 9 Pressure relief valve Operates if the pressure in the boiler ex...

Page 8: ...x 22 When the time window displays Long the generator will operate continuously until it is switched off MODEL Detected Scope Max Cut out Temperature Size mm o C o F o C o F L W H OC S 0 110 32 230 60...

Page 9: ...is filling green water level OK Note if the LED remains red in excess of 5 minutes check water supply 12 L3 Indicator LED for drain red for draining green for draining and filling at the same time 13...

Page 10: ...r and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the steam pipe The steam pipe should be metal of other material that can endure 150 C tempe...

Page 11: ...holes in the back plate Then with the front cover removed fix the 3rd screw to secure the unit in place 10m The steam generator can be installed anywhere that is dry and has an airflow Example locati...

Page 12: ...er supply using a flexible hose with 1 2 inch fittings iii Steam outlet 1 2 inch or 3 4 inch use the same dimension copper pipe to connect it if the steam pipe is longer than 5 meter it should be insu...

Page 13: ...rom the steam outlet Use a 4mm screw fix it in place and then connect to the wire from the controller vi Fix protective cover supplied over the temperature Temperature Sensor 4mm Screw Cover to protec...

Page 14: ...operators may wish to take advantage of the steam on demand function which will allow customers to press the steam on demand button located outside the steam room after which the generator will opera...

Page 15: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 15 Steam Generator Manual...

Page 16: ...es the factory the default settings are 40o and 1 hour of operation these can be adjusted as follows i Time setting press set key the time display window will flash press to adjust the time every pres...

Page 17: ...main circuit board the transformer has failed or has a loose connection Control panel lit up but no steam Water probe Control lead connection Water supply 1 If L2 is green L7 is yellow remove the wat...

Page 18: ...d mixed with water Citric acid can be purchased from www thebathingplace com www oceanic saunas eu 12 1 Descaling procedure i Firstly push the drain button to empty the tank check the valve is drainin...

Page 19: ...trical elements and failures resulting from misuse or abuse such as a failure to descale as explained previously If you are using the generator for more than 20 hours a week in a hard water area witho...

Reviews: