background image

OPUS® G2

USER GUIDE 

Pro-Line

®

 / Slim-Line

®

EN

Summary of Contents for OPUS G2

Page 1: ...OPUS G2 USER GUIDE Pro Line Slim Line EN...

Page 2: ...2 VIDEO INSTRUCTIONS EQUIPMENT INSTALLATION VIDEO INSTRUCTIONS STARTING THE TANK VIDEO INSTRUCTIONS INTRODUCING LIVE STOCK...

Page 3: ...G2 aquarium Before putting the product into operation please read the user guide and safety instructions carefully CONTENTS SAFETY INSTRUCTIONS 4 BEFORE ASSEMBLY 6 FUNCTIONALITY AND EQUIPMENT REQUIRE...

Page 4: ...SAFETY INSTRUCTIONS 4 Fig 1...

Page 5: ...1 This product is approved exclusively for use indoors and only for aquarium applications Do not move the aquarium when filled or attempt to lift it Even when the aquarium is empty never lift it by th...

Page 6: ...base surface of approx 90x60cm 39 x 26 in and a weight of approx 500 kgs 1 100 lbs when filled In case of doubt consult a structural engineer in this regard The aquarium should not be exposed to direc...

Page 7: ...the wall For reasons of accessibility the OPUS G2 should exhibit a distance of approx 60cm 24 in from neighbouring walls or furniture on both the right and left side Fig 2 Make sure the floor cover ar...

Page 8: ...CTURE OF SUMP Chamber 1 Sedimentaion chamber for the outflow water from the display tank Chamber 2 Filter sock filters dirt particles out of the water Chamber 3 The main filter chamber also known as t...

Page 9: ...1 2 3 4 5 9 EN Fig 3...

Page 10: ...porate only use fresh wa ter RODI Water as compensation for water lost through evaporation IMPORTANT As the refill tank is higher than the water le vel in the sump please ensure that the refill water...

Page 11: ...installed in compliance with the manufacturer s safety instructions Check the correct installation of the pipework once more First fully close the valve by turning it clockwise Fill the overflow box...

Page 12: ...slightly It takes several minutes for the water level to adjust to the respective valve settings The valve is correctly set if no further outflow noise can be heard and the desired water level in the...

Page 13: ...e is correctly set MAINTENANCE AND CARE FILTER SOCK The filter sock must be cleaned at regular intervals Rinse out the filter sock under running water or wash it in the washing machine on a cold setti...

Page 14: ...ilter comb on the overflow box at regular intervals to remove algae deposits etc Check that no foreign bodies are present inside the out flow and emergency outflow Clean the pipes of encrustations cor...

Page 15: ...ump DISPLAY TANK When cleaning the panes of the display tank and sump with a scraper make sure the blades do not damage the silicone seams Do not use magnetic cleaners to clean the rear pane of the di...

Page 16: ...www facebook com nyos aquatics Nyos Aquatics GmbH Siemensstr 26 70825 Korntal Muenchingen Germany www nyos info support nyos info...

Reviews: