background image

OPUS® 300

INSTRUCTIONS

Summary of Contents for OPUS 300

Page 1: ...OPUS 300 INSTRUCTIONS...

Page 2: ...2 VIDEO INSTRUCTIONS AQUARIUM ASSEMBLY VIDEO INSTRUCTIONS EQUIPMENT INSTALLATION VIDEO INSTRUCTIONS STARTING THE TANK VIDEO INSTRUCTIONS ADDING LIVE STOCK...

Page 3: ...quarium Before putting the product into operation please read the instructions carefully CONTENTS SAFETY INSTRUCTIONS 4 ASSEMBLY 6 FUNCTIONALITY AND EQUIPMENT REQUIRED 17 STARTING THE TANK 20 MAINTENA...

Page 4: ...SAFETY INSTRUCTIONS 4 Fig 1...

Page 5: ...water level Fig 1 This product is approved exclusively for use indoors and only for aquarium applications Do not move the aquarium when filled or attempt to lift it Even when the aquarium is empty nev...

Page 6: ...s STEP 1 SELECTION OF THE INSTALLATION SITE The floor on which the OPUS 300 is installed must be level The floor on which the OPUS 300 is installed must be sufficiently load bearing The OPUS 300 has a...

Page 7: ...he wall For reasons of accessibility the OPUS 300 should exhi bit a distance of approx 60 cm 24 in from neighbouring walls or furniture on both the right and left side Make sure the floor covering aro...

Page 8: ...ium out of the cabinet with the help of a second person When doing so make sure the aquarium remains straight and level when lifted out to avoid damage to the cabinet Set the aquarium down on the prep...

Page 9: ...of at least one further person Align the aquarium cent rally so that the gap between the cabinet and aquarium is evenly sized on all sides No underlay is required between the aquarium and the cabinet...

Page 10: ...P The transparent acrylic panel with the two PVC threaded connections is fastened at the rear right on the sump with the two transparent plastic screws Fig 2 Install the filter sock in the sump at the...

Page 11: ...hen screw tight in the overflow box hand tight do not over wind tool is not required The pipe with the largest diameter sits in the middle the two narrower pipes are identical and are fitted adjacent...

Page 12: ...elongs in the left chamber of the sump return chamber We recommend that the Auto Top Off system be installed only after the aquarium has been filled with seawater see page 22 step 4 The cover panels c...

Page 13: ...ASSEMBLY STEP 7 INSTALLING THE PUMP OUTLET An outlet port is located in the overflow box for the pump outlet This can be simply fitted on the pump outlet in the aquarium 13 EN...

Page 14: ...and the screws provided part number 29 Fig 8 Now attach the doors with hinges to the cabinet using the pre drilled holes and the screws provided part num ber 29 A second person should hold the doors F...

Page 15: ...ALLING THE CABINET LIGHTING The LED lighting can be fastened in the cabinet at the top right or top left see sketch Before fastening check that it switches on when the door is opened and off when the...

Page 16: ...arium and cabinet Start on the rear side of the aquarium roughly in the centre beneath the overflow box Fit the silicone cord with a little excess material at the corners of the aquarium so that the c...

Page 17: ...inimum SUMP 1 A bubble trap is located in the right rear chamber of the sump 2 The water subsequently flows via a filter sock which filters dirt particles out of the water 3 At the front right in the...

Page 18: ...6 In the chamber far left the water is fed back into the display tank via the return pump Because the water level in the return chamber varies compensation for the water lost through evaporation takes...

Page 19: ...options for successfully operating a reef aquarium The following components are recommended on the basis of our experience INFORMATION ON THE RETURN PUMP The maximum pump capacity of the Nyos OPUS 300...

Page 20: ...components skimmer return pump etc are installed in compliance with the manufacturer s safety instructions The Auto Top Off system is only required once the aqua rium is in operation We therefore rec...

Page 21: ...t the valve opens further As soon as you begin to approach to the correct settings the valve should only be turned slightly It takes a few minutes for the water level to adjust to the respective valve...

Page 22: ...e abo ve the intake of the return pump so that the pump does not draw in air Now connect the Auto Top Off system and the refill tank with the transparent hose provided and set the refill tank on the t...

Page 23: ...647 part no 21 Note If the filter sock is clogged the water no longer flows through the filter sock but rather over it The func tion of the sump remains intact VALVE The valve can be opened and cleane...

Page 24: ...mp outlet and the filter comb on the overflow box at regular intervals to remove algae deposits etc Check that no foreign bodies are present inside the out flow and emergency outflow Clean the pipes o...

Page 25: ...ump DISPLAY TANK When cleaning the panes of the display tank and sump with a scraper make sure the blades do not damage the silicone seams Do not use magnetic cleaners to clean the rear pane of the di...

Page 26: ...EXPLODED DRAWING 26 6 7 1 2 3 4 5 27 30 31 32 8 9 10 11 12 13 14 15 20 24 25 21 26 22 23 33 27 28 29...

Page 27: ...on 1 Display tank including complete overflow box 2 OPSP_0432 2 Complete overflow box Body cover pump outlet 3 4 OPSP_0449 3 Overflow box cover OPSP_0456 4 Pump outlet consisting of three components O...

Page 28: ...P_0494 7 Outflow pipe straight 32 mm for main outflow including seal 17 OPSP_0500 8 Inflow pipe angled 20 mm for return pump including seal 19 OPSP_0517 9 Pipe adapter 20 mm for return pump complete t...

Page 29: ...tflow angled 32 mm inclu ding seal 12 13 18 OPSP_0548 12 Diaphragm for valve OPSP_0555 13 Screw kit and rubber caps for valve 4 units OPSP_0562 14 Transparent acrylic glass with 2 x PVC pipe and threa...

Page 30: ...no Illustration 16 Seal for outflow inflow pipe straight 20 mm OPSP_0593 17 Seal for outflow pipe straight 32 mm OPSP_0609 18 Seal for 32 mm threa ded connection OPSP_0616 19 Seal for 20 mm threa ded...

Page 31: ...des part no Article no Illustration 21 Filter sock OPSP_0647 22 Cover panel sump right OPSP_0654 23 Cover panel sump left OPSP_0661 24 Auto Top Off system without hose OPSP_0678 25 Hose for Auto Top...

Page 32: ...ustration 26 Refill tank OPSP_0692 27 Cabinet including doors and hinges push knobs 28 29 30 Wei OPSP_0708 Grau OPSP_0715 28 Hinges for cabinet doors 2 units OPSP_0722 29 Screws for hinges 4 units OPS...

Page 33: ...Part no Part name This part also inclu des part no Article no Illustration 31 Lighting for cabinet OPSP_0753 32 Foot for cabinet 1 unit OPSP_0760 33 Underlay for sump OPSP_0777 PARTS LIST 33 EN...

Page 34: ...NOTES 34...

Page 35: ...NOTES 35 EN...

Page 36: ...www facebook com nyos aquatics Nyos Aquatics GmbH Siemensstr 26 70825 Korntal Muenchingen Germany www nyos info info nyos info...

Reviews: