Page 1

MODELS  754RBNT • 754SNNT

DECORATIVE SERIES

CEILING VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

WARNING  

 

TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OB-

SERVE THE FOLLOWING:

1. Use this unit only in the manner intended by

the manufacturer. If you have questions, con-

tact the manufacturer at the address or tele-

phone number listed in the warranty.

2. Before servicing or cleaning unit, switch power

off at service panel and lock the service dis-

connecting means to prevent power from be-

ing switched on accidentally. When the ser-

vice disconnecting means cannot be locked,

securely fasten a prominent warning device,

such as a tag, to the service panel.

3. Installation work and electrical wiring must be

done by a qualified person(s) in accordance

with all applicable codes and standards, in-

cluding fire-rated construction codes and stan-

dards.

4. Sufficient air is needed for proper combus-

tion and exhausting of gases through the flue

(chimney) of fuel burning equipment to pre-

vent backdrafting. Follow the heating equip-

ment manufacturer’s guideline and safety

standards such as those published by the

National Fire Protection Association (NFPA),

and the American Society for Heating, Refrig-

eration and Air Conditioning Engineers

(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do

not damage electrical wiring and other hid-

den utilities.

6. Ducted fans must always be vented to the out-

doors.

7. NEVER place a switch where it can be

reached from a tub or shower.

8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently

protected.

CAUTION  

!

1. For general ventilating use only. Do not use

to exhaust hazardous or explosive materials

and vapors.

2. This product is designed for installation in

FLAT CEILINGS ONLY. Do not mount this

product in a wall.

3. The light fixture assembly must be mounted

to the fan housing assembly included with this

product. 

Do not mount the light fixture as-

sembly to a wiring outlet box.

4. To avoid motor bearing damage and noisy

and/or unbalanced impellers, keep drywall

spray, construction dust, etc. off power unit.

5. Please read specification label on product for

further information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED

TO ADDITIONAL FRAMING

Discharge 90

0

 to joists.

HOUSING MOUNTED

DIRECTLY TO JOIST

2x6 (or larger)

Discharge parallel to joists.

HOUSING MOUNTED

TO 2x4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO 2x4

TRUSS

Requires additional framing

for mounting tabs.

Discharge 90

0

 to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing

for mounting tabs.

Discharge 90

0

 to joists.

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 4.

*

 Additional framing must be a 2x6 (minimum height), at least 9-inches long.

*

*

*

*

*

Summary of Contents for 754RBNT

Page 1: ...ing and other hid den utilities 6 Ducted fans must always be vented to the out doors 7 NEVER place a switch where it can be reached from a tub or shower 8 This unit must be grounded 9 This unit is U L listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT C...

Page 2: ...le performance use the shortest possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1 1 1 4 thick ceiling material Holes in corners of housing are labeled with various ceiling material thicknesses Position housing so bottom edge of joist is visible throu...

Page 3: ...L Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 ...

Page 4: ...uctions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE SOBLIGATIONTOREPAIRORREPLACE ATNUTONE SOPTION SHALLBETHEPURCHASER SSOLEANDEXCLUSIVEREMEDYUNDERTHISWARRANTY NUTONESHALLNOT BELIABLEFORINCIDENTAL CONSEQUENTIAL...

Page 5: ...conductossiempredebentenersalida hacia el exterior 7 Nuncacoloqueelinterruptorenunlugarendondesepueda alcanzar desde la tina o ducha 8 Esta unidad se debe conectar a tierra 9 EstaunidadestáincluidaenlalistadeU L TipoI C proteger inherente PRECAUCIÓN 1 Esta unidad debe usarse solamente para ventilación gen eral No la utilice para la descarga de materiales ni vapores peligrosos o explosivos 2 Este p...

Page 6: ...que el borde inferior de la cubierta quede al ras del cielo raso terminado Característica adicional para la colocación en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubierta están marcados con varios espesores del material del cielo raso Coloque la cubierta de manera que el borde inferior de la vigueta sea visible a través del con...

Page 7: ...cubierta La parte superior del conector del regulador de tiro conducto debe quedar al ras de la parte su perior de la cubierta 2 Conecte el conducto redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exte rior a través de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que abre libremente Coloque cinta en todas las conexio...

Page 8: ...s de instalación La duración de cualquier garantía implícita se limita a un período de un año según se especifica en la garantía explícita Algunos estados no permiten limitación a la duración de una garantía implícita por lo que esta limitación tal vez no se aplica al caso suyo LA OBLIGACION DE NUTONE DE REPARAR O CAMBIAR A OPCION DE NUTONE SERA EL UNICO Y EXCLUSIVO REMEDIO AL COMPRADOR BAJO ESTA ...

Reviews: