Operator Manual for Element  

C-Band 10W BUC 

 

 

 

 

 

 

 

Summary of Contents for Element C-Band BUC

Page 1: ...Operator Manual for Element C Band 10W BUC ...

Page 2: ...scription 5 1 2 Safety 6 2 1 Intermediate Frequency IF 10MHz Reference Input 7 2 2 Torque Value 8 2 3 RF Output 8 2 4 AC DC Connector 8 3 1 Element BUC Installation 10 Check packing list 10 Installation of mounting bracket 10 Connecting coaxial cable and DC 11 Installation of OMT to CPR137G 11 Waterproof 11 4 1 Maintenance 13 4 2 Troubleshooting 13 ...

Page 3: ...S Figure 2 1 F Type female connector 7 Figure 2 2 N Type female connector 7 Figure 2 3 CPR137G RF Output Port 8 Figure 2 4 MS 5pin for AC 9 Figure 2 5 MS 2pin for DC 9 Figure 3 1 Location of mounting bracket holes 10 Figure A 4 1 Element 10W BUC DC Power 14 Figure A 4 2 Element 10W BUC AC Power 15 ...

Page 4: ... International Inc Norsat All Rights Reserved 2022 06 01 DOC 001803 Rev A 4 LIST OF TABLES Table 2 1 Torque Value 8 Table 3 1 Torque Value 11 Table 3 4 Torque Value 11 Table B 4 1 Acronyms and Abbreviations 16 ...

Page 5: ...tallation and operation Introduction of BUC The BUC is designed to use for VSAT application Norsat BUC has high linearity and gain stability over the full operating temperature range The standard output operating frequency range is 5 850GHz to 6 425GHz Other frequency options are also available ranging from 5 850GHz to 7 025GHz The BUC requires a reference signal 10MHz either externally or interna...

Page 6: ...ion 3 Do not operate the BUC without a load or termination attached to the RF signal output 4 Do not expose the BUC to standing water Failure to follow this precaution could result in electric shock and injury to persons 5 The BUC should be installed in an electrically stable situation because it may cause serious injuries to persons as well as damage to the BUC 6 Do not perform maintenance to the...

Page 7: ...Intermediate Frequency IF 10MHz Reference Input Intermediate Frequency IF and 10MHz reference signal are provided through F or N type connector F or N type connector is used for the input port as shown in Figure 2 1 and Figure 2 2 Figure 2 1 F Type female connector Figure 2 2 N Type female connector ...

Page 8: ... is shown in Table 2 1 Table 2 1 Torque Value Connector Torque value N m F type 0 39 0 49 N type 0 68 1 13 1 kg f cm 0 0980 N m 2 3 RF Output CPR137G waveguide Grooved is used for the RF output port as shown in Figure 2 3 2 4 AC DC Connector MS 5pin connector is used for AC and MS 2pin connector is used for DC as shown in Figure 2 4 and Figure 2 5 Figure 2 3 CPR137G RF Output Port ...

Page 9: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2022 06 01 DOC 001803 Rev A 9 Figure 2 4 MS 5pin for AC Figure 2 5 MS 2pin for DC ...

Page 10: ...packing list Perform an initial inspection upon receiving the BUC as per the following instruction Check that the shipping container is not damaged Check that all items in the packing list are not damaged Check that all items in the packing list are present Installation of mounting bracket Install the mounting bracket using the two 2 M6 mounting holes at each side of BUC as shown in Figure 3 1 The...

Page 11: ... waterproof Installation of OMT to CPR137G BUC can be mounted with waveguide filter or OMT of antenna Do not block fins and air opening of the fan Please follow the guidelines below 1 Clean the gasket groove on the waveguide flange 2 Insert the enclosed gasket to the groove 3 Use the enclosed bolts and washers 8pcs to install OMT 4 The torque value to install OMT is shown in Table 3 2 Table 3 2 To...

Page 12: ...at All Rights Reserved 2022 06 01 DOC 001803 Rev A 12 2 Tighten connector and coaxial cable all the way to the end 3 Tightly wrap the connector and coaxial cable with the self amalgamating tape 4 Tightly wrap the waveguide filter or OMT with the self amalgamating tape ...

Page 13: ...ired for normal operation Periodic cleaning of the heat sink fins will ensure adequate ambient cooling Not to cover the fan which may increase the heat sink temperature 4 2 Troubleshooting The recommended action below provides some help to quickly isolate a fault within the BUC module If the BUC module is defective notify Norsat of a written description of the problem encountered the part number a...

Page 14: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2022 06 01 DOC 001803 Rev A 14 Appendix A Mechanical Drawings Figure A 4 1 Element 10W BUC DC Power ...

Page 15: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2022 06 01 DOC 001803 Rev A 15 Figure A 4 2 Element 10W BUC AC Power ...

Page 16: ...s The following is a list of acronyms and abbreviations referenced in this document Table B 4 1 Acronyms and Abbreviations Acronym Definition BUC Block Upconverter IF Intermediate Frequency DC Direct Current GHz Gigahertz GND Ground M C Monitor and Control MHz Megahertz mm Millimeter RF Radio Frequency RX Receive TX Transmit V Volt VDC Volts Direct Current ...

Page 17: ...remote and challenging applications Norsat s products and services include customizable satellite components portable satellite terminals maritime solutions and satellite networks The company s products and services are used extensively by telecommunications services providers emergency services and homeland security agencies military organizations health care providers and Fortune 1000 companies ...