background image

1

 

 

PN782163 REV 20180814 

 

SINGLE SERVING AUTOMATIC POD MACHINE

 

FKP-4

 

NEWCO ENTERPRISES INC,

 

3650 NEW TOWN BLVD 

SAINT CHARLES, MO 63301

 

1-800-325-7867

 

FAX 1-636-925-0029

 

     

                          

 

Features/ Specifications

 

 
 

• 

AUTOMATIC POD REMOVAL

 

• 

FLOWMETER

 

• 

20 OZ TRAVEL MUG

 

• 

LARGE POD WASTE TRAY / THRU COUNTER OPTION

 

• 

ADJUSTABLE DRINK STRENGTH

 

• 

ADJUSTABLE DRINK VOLUME

 

Summary of Contents for FKP-4

Page 1: ...P 4 NEWCO ENTERPRISES INC 3650 NEW TOWN BLVD SAINT CHARLES MO 63301 1 800 325 7867 FAX 1 636 925 0029 Features Specifications AUTOMATIC POD REMOVAL FLOWMETER 20 OZ TRAVEL MUG LARGE POD WASTE TRAY THRU COUNTER OPTION ADJUSTABLE DRINK STRENGTH ADJUSTABLE DRINK VOLUME ...

Page 2: ...2 LEFT BLANK INTENTIONALLY ...

Page 3: ... SET UP 6 MACHINE OPERATION 7 MACHINE PROGRAMMING 8 DRAINING THE HOT WATER TANK 12 SERVICING THE MACHINE 11 REMOVING THE BREW MECHANISM 11 SIDE PANEL REMOVAL 13 TANK REMOVAL ACCESS AREAS 14 POD BREWING MECHANISM 15 TANK ASS Y 16 ELECTRICAL COMPONENTS 17 WIRING DIAGRAM 19 ...

Page 4: ...S 1700W 120V CANADA 1400W 120V INTERNATIONAL 1700W 220V TANK CAPACITY 1 US GALLON DRIP TRAY CAPACITY 8 OUNCES POD WASTE TRAY CAPACITY 40 PODS USE WASTE TRAY PN 780306 FOR THRU COUNTER USE UP TO 20 OZ CUP SIZE SHIPPING WT APPROX 35 LBS ...

Page 5: ...rranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location and 3 receiving prior authorization from Newco that the defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY WRITTEN OR ORAL EXPRESS OR IMPLIE...

Page 6: ... ft run use 1 4 tubing and connect to 1 2 or larger water line The inlet water fitting on the back of the brewer is a 1 4 flare fitting It may be necessary to remove the plumbing cover box on the rear of brewer to access water connection point 4 If installed with saddle valve the valve should have a minimum of 1 8 porthole for up to 25 ft run and 5 16 porthole for over 25 ft runs 5 Turn on water s...

Page 7: ...EEPER CAN BE SHUT OFF AIR PUMP POD DRYING TIME PUMP STRENGTH CAN BE ADJUSTED POD COUNT TO EMPTY POD WASTE BIN AJDUSTABLE OR CAN BE TURNED OFF IF USING THROUGH THE COUNTER WASTE BIN COFFEE OR TEA PRE INFUSION BREW TIME BREW VOLUME ADJUSTABLE FOR EACH OF 6 CUSTOMIZABLE DISPENSE BUTTONS BREW OPERATION 1 PLACE CUP UNDER BREW NOZZLE ON DRIP TRAY 2 PRESS THE DRAWER OPEN BUTTON 3 UNWRAP THE POD PLACE IN ...

Page 8: ...THER ADJUSTMENTS ARE NECESSARY IF THE FACTORY DEFAULTS ARE USED B C D E F Fig 1 Fresh Cup Keys The Fresh Cup pod brewer has a menu that consist of scrolling menu entries that can be scanned through backward and forward using button A and button B see Fig 1 To enter a programming record press and hold the Hot Water Key G when powering up machine see Fig 1 Then use button A and button B see Fig 1 to...

Page 9: ...d until a key is pressed Set Energy Save Time This entry will not be displayed if the Power Save function has been turned off This entry sets the time the machine will operate normally until the power save function is activated The user can choose 1 through 4 hours in 1 hour increments with the default set to 4 hours As with most of the entries button A and button B see Fig 1 will change the time ...

Page 10: ...efault set to 7ounces SET PRE INFUSION VOLUME This entry sets the time of the pre infusion pulse of water in seconds Range is 0 to 3 0 Default varies by drink SET COFFEE PUMP SPEED In this entry the user may set the pump strength in the range of 10 to 100 strength with the default at 35 As with most of the entries button A and button B see Fig 1 will change the Pump Strength incrementing or decrem...

Page 11: ...bed below The following entries only show when a filter is selected If the filter selection is OFF then following entries are not available Pressing the Hot Water key G see Fig 1 to leave the entry and return to the Main Programming menu GAL REMAINING This entry scrolls the number of Gallons left before the filter should be replaced Pressing the Hot Water key G see Fig 1 to leave the entry and ret...

Page 12: ...LACE DRAIN PLUG ENSURE HOSE CLAMP IS TIGHT AND REPOSITION DRAIN HOSE BEFORE RE FILLING THE HOT WATER TANK SERVICING THE MACHINE The Fresh Cup machine has a modular Water Tank Assembly and Brew Mechanism These assemblies can be easily removed from the machine by removing or loosening Machine nuts as noted in drawings below REMOVING THE BREW MECHANISM BREW MECHANISM ACCESS SCREWS VIEW FROM BOTTOM OF...

Page 13: ...VAL 1 LOOSEN 2 SCREWS THEN REMOVE COVER PANEL 3 SLIDE PANEL TO THE REAR OF THE MACHINE 2 REMOVE 2 SCREWS FROM REAR OF SIDE PANEL 4 LIFT PANEL UP AND RELEASE TOP FLANGE 5 SLIDE PANEL DOWN 6 SLIDE PANEL FORWARD TO RELEASE ...

Page 14: ... TWO ON TOP OF TANK LOOSEN SCREWS TO REMOVE TOP BACK COVERS LOOSEN BUT DO NOT REMOVE THESE 2 SCREWS THEN LIFT PULL CONTROL BOARD BRACKET OUT OF MACHINE TO ACCESS TRANSFORMER REMOVE 2 6 32 SCREWS TO REMOVE SIDE PANEL FOR PUMP ACCESS REMOVE TOP COVER BEFORE REMOVING SIDE PANELS ...

Page 15: ... 2 1 4 773246 U CUP SEAL RING 1 5 780539 CHAMBR UP I H BR 56 61MM 1 6 780554 EJECT SLOPE CAM ASS Y 1 7 780588 MOLDED BUMP DISC PAD 1 9 780546 KICKER SLIDE WASHER 1 10 780536 X 1 STAINLESS STANDOFF SPACER 1 11 780541 COMPRESSION SPRING 1 12 780264 LOWER BREW CHAMBER O RING 1 13 780096 GUTTER BREW MECH 1 POD BREWING MECHANISM 780585 ...

Page 16: ...1 7 500396 LIQUID LEVEL PROBE BUSHING 2 8 151677 DUAL TEMP THERM PROBE 1 9 100149 ELBOW C X 1 8 NPT 1 10 704166 10 1700W 704161 10 1400W TANK HEATING ELEMENT US TANK HEATING ELEMENT CAN 1 11 120682 FLOWMETER 1 12 767281 WYE HOSE FITTING 1 13 202165 AIR PUMP CHECK VALVE 1 14 202166 WATER PUMP CHECK VALVE 1 15 780748 HEX SPACER FOR AIR PUMP NOT SHOWN 1 16 780749 CLAMP LOOP VIBRAT DAMP NOT SHOWN 1 TA...

Page 17: ...CAL COMPONENTS 5 4 2 3 1 ITEM NEWCO PN DESCRIPTION QTY EA 1 782187 CONTROL BOARD BRACKET 1 2 110626 SWITCH DPST ON OFF 1 3 102383 SOLENOID FILL VALVE 1 4 105115 TRANSFORMER 120VAC 24VAC 1 5 780601 DISPLAY BOARD 1 ...

Page 18: ...sage CONTACT SERVICE TOP BTM BREW MOTOR OPEN BREW CHAMBER DRIVE MOTOR ERROR CHECK FOR JAM OR OBSTRUCTION IN BREW CHAMBER Message CONTACT SERVICE CHECK WATER WATER NOT REACHING LEVEL PROBE CHECK WATER SUPPLY OR CHECK FOR WATER LEAK Message CONTACT SERVICE CHECK WATER WATER NOT HEATED DURING TIMEOUT PERIOD CHECK HEATER RELAY PN 110958 OR HEATING ELEMENT PN 704166 10 1700W US OR 704161 10 1400W CANAD...

Page 19: ...19 WIRING DIAGRAM ...

Page 20: ...20 LEFT BLANK INTENTIONALLY ...

Page 21: ...21 LEFT BLANK INTENTIONALLY ...