background image

5S12000

 

 

 

New Comfort

 

Summary of Contents for SS12000

Page 1: ...5S12000 New Comfort ...

Page 2: ...1 ...

Page 3: ...AC110V Press the Ozone Timer button to adjust the amount of time and area size to be treated Press the Fan button to adjust the fan speed Allow returning to the treated space after stopping working for 40 minutes and Keep ventilation Leave immediately if you feel uncomfortable 6 open doors and windows for ventilation Ozone Fan Power Interval Timer 5 Ozone Fan Power Interval Timer 4 Ozone Fan Power...

Page 4: ...3 PAGES 1 2 Quick Start Safety 3 Table of Contents 4 Introduction 5 Specifications 6 Usage 7 Control Panel 8 Application 9 Replace Ozone Modules 10 Trouble Shooting 11 12 Warranty Service CONTENTS ...

Page 5: ...4 ...

Page 6: ...5 ...

Page 7: ...the unit and an active grounded power outlet 2 Set the timer according to the area size and time table below 3 The generator will automatically turn off after the timer has finished 4 To choose the Interval function press once the unit will work in 12 hour interval press twice it will work in 24 hour interval press three times to cancel the interval work 5 Allow 40 minutes for the space to air out...

Page 8: ...7 ...

Page 9: ...s 7 Breeding industry regular disinfection and sterilization of space sites 8 Disinfection and sterilization of Warehouse cold room 9 Others Any place where the air needs to be disinfected and sterilized any place that needs to eliminate peculiar smell Before use humans animals pets should leave the treated area where machines working prevent humans or animals go into this area To reduce the risk ...

Page 10: ...o replace the ozone module in order to maintain better performance 1 Unplug the power cord 2 Press and pull out the old ozone module assembly at the bottom 3 Insert the new ozone module assembly and hear a click sound the replacement is complete Heat sink Ozone plate Ozone plate holder OZONE PLATE ASSEMBLY BOTTOM VIEW ...

Page 11: ...ate is dirty Activates the switch replace new or clean the ozone plate The Unit is starting but no ozone The ozone plate is consumed activates the wait and delay function Replace a new ozone plate Cancel the wait and delay function How to replace the Fuse Need to replace a new fuse when the previous fuse is breaks 1 Pull out the plastic fuse holder and take out the previous fuse 2 Take out the spa...

Page 12: ...h the product which is not covered by the warranty Product After Sales Service1 Please contact an authorized New Comfort distributor The New Comfort SS 12000 commercial air purifier is covered by a 3 Year Limited Factory Warranty The warranty covers the complete unit except for filters or Ozone Plates New Comfort or its authorized service centers shall pay for all parts and labor for authorized wa...

Page 13: ......

Reviews: