background image

 

8233D PRO-EN 

Table of Contents 

1.

 

Introduction    ………………………………………………............................ 1 

2.

 

Safety note      ……………………………………………..…....................... ...2   

3.

 

Explanation of Controls and Indicators …………………..................... 3 

3-1. Product illustration     

………………………………………........................3

 

3-2. Functional push button   

……………………………………......................4

 

3-3. LCD display   

………………………………………………..............................5 

4.

 

Specification    ……………………………………………….............................5 

4-1. General Specification   

……………………………………......................... 6

 

4-2. Electrical Specification   

………………………………….......................7- 9 

5.

 

Measurement operation    …………………………………........................9 

5-1    DC voltage & AC voltage measurement   

……………….................. 9

 

5-2.    Resistance measurement   

…………………………….…....................10

 

5-3.    Diode & Continuity check 

  ………………………..…..…...................11

 

5-4.    Frequency Measurement    ................................

…….……...........11

 

5-5.    DC/AC 

µ

A or mA measurement   

………………….……...................12

 

5-6.    DC/AC 10A measurement   

…………………………..….....................12

 

5-7.    Capacitance measurement.............................………...…...............

13

 

6. Maintenance        ……………………………………………….............................13 

6-1. Replacing the battery     

…………………………...……….......................13 

6-2. Replacing the fuse     

……………………………………….........................14 

Summary of Contents for 8233D Pro

Page 1: ...cation 5 4 1 General Specification 6 4 2 Electrical Specification 7 9 5 Measurement operation 9 5 1 DC voltage AC voltage measurement 9 5 2 Resistance measurement 10 5 3 Diode Continuity check 11 5 4...

Page 2: ...urement tool and widely used in the school laboratory factory and other social field 2 Safety note Warning To avoid possible electric shock or personal injury and to avoid possible damage to the meter...

Page 3: ...Ground AC Alternating current Warning see explain in manual DC Direct Current Double insulation AC or DC Fuse Measurement category over voltage category This instrument is meet the safety condition of...

Page 4: ...ig 1 Exterior view 1 LCD display 2 FUNC Push button 3 BACK LIGHT push button and HOLD push button 4 Rotary Switch Knob 5 V HZ uA mA Input terminal 6 COM input terminal 7 10A input terminal 3 2 Functio...

Page 5: ...to enter and exit the hold mode in any mode That act with trigger HOLD This key is used control Backlight This key is act with trigger When press and hold the key over 2 sec will enable Backlight Pre...

Page 6: ...battery indication Auto Power OFF If the meter is idle for 15 minutes idle time the meter automatically turns the power off After auto power off pushing any of the push button or changing the rotary s...

Page 7: ...Manual 1pc 2 Test lead 1set 3 9V Battery 1pc 4 2 Electrical Specification at 23 5 75 RH 4 2 1 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 rdg 2dgt 2V 0 001V 20V 0 01V 200V 0 1V 600V 1V 0 8 r...

Page 8: ...olution Function 0 001V Will display the forward drop voltage Operating current about 1mA Open circuit voltage about 1 48V 4 2 5 Continuity Range Function If measured resistance less than 100 will buz...

Page 9: ...0 rdg 20dgt 1000 2000 F 1 F 5 0 rdg 40dgt Over Load protection use the fuse F250mA 250V 4 2 8 AC Current 40Hz 400Hz Range Resolution Accuracy 200 A 0 1 A 1 5 rdg 4dgt 2000 A 1 A 20mA 0 01mA 200mA 0 1...

Page 10: ...minal Set the rotary switch to DC or AC range Connect the test lead across with the object under testing The measured value will be show on the LCD display Note When DC or AC voltage measurement has b...

Page 11: ...1 Diode Set the rotary switch to position First time default mode is diode check mode You can enter the continuity check mode by the FUNC Key insert the red test lead into the V terminal and the black...

Page 12: ...on the LCD display NOTE Input signal level must be higher than 0 5V it is sensitivity 5 5 DC AC A or mA measurement DC Current range is 200 0 A 2000 A and 20 00mA 200 0mA and then 10A range AC Current...

Page 13: ...nd all high voltage capacitors discharge DC voltage function determines the capacitor has been discharged Capacitance is component s ability to store charge The unit of capacitance is ferrari F Most o...

Page 14: ...r Open the battery cover on the bottom case by screwdriver Remove old battery and snap new one into battery holder 6 2 Fuse replacement Replacing the defective fuse should the done according to the fo...

Page 15: ...nty of 18 months from the day of purchase if you need any support please feel free to contact us Contact Here is the steps for you to contact the correct seller Highly recommend 1 Log in your amazon a...