background image

MPO-700

Neobotix GmbH

Feb 25, 2022

Summary of Contents for MPO-700

Page 1: ...MPO 700 Neobotix GmbH Feb 25 2022 ...

Page 2: ...1 Dimensions 5 1 3 2 Absolute Maximum Ratings 6 1 3 3 Positions of Sensors 6 1 3 4 Electrical Properties and Miscellaneous Data 6 1 3 5 Communication To Internal Devices 8 1 4 Transport 9 1 4 1 Packaging 9 1 4 2 Unpacking the Robot 9 1 4 3 Short Distance Transport 9 1 4 4 Long Distance Transport 10 1 4 5 Shipping with AGM Battery 10 1 4 6 Shipping with LiFePO4 Battery 10 1 5 Maintenance 11 1 5 1 C...

Page 3: ... Cooperating with the Robot 26 2 6 5 Bringing into Service 27 2 6 6 Modification of the System 27 2 6 7 Expected Misuse 27 2 6 8 Configuring the Safety Fields 28 2 7 Safety Instructions Manipulators 29 2 7 1 Robot Arms 29 2 7 2 Laser Scanners 29 2 7 3 Working required from the Customer 29 2 8 Maintenance 30 2 8 1 Cleaning 30 2 8 2 Maintenance and Repairs 30 2 9 Qualified Personnel 31 2 10 Taking o...

Page 4: ...39 3 4 2 Communication Interfaces 44 3 4 3 Digital I Os 45 3 5 Configuration 47 3 5 1 Connecting to the Amplifiers 48 3 5 2 Handling Different Configurations 50 3 5 3 Advanced Settings 51 3 5 4 Testing and Debugging 52 3 6 Maintenance 52 3 6 1 Cleaning 52 3 6 2 Traction Wheel 52 3 7 Technical Data 53 3 7 1 Dimensions 53 3 7 2 Board Layout 53 3 7 3 Properties 54 3 8 Taking out of Service 54 3 9 Leg...

Page 5: ...e Omni Drive Modules of the MPO 700 feature important benefits compared to other omnidirectional drive kinematics like for example the MPO 500 s Mecanum wheels Fully omnidirectional manoeuvrability Very steady movements High stability and payload Compact easily integrated drive units This makes the MPO 700 a premium alternative for applications that require omnidirectional movements without the li...

Page 6: ...ading cargo its safe operation must be assessed and approved Without the safety approval described above the mobile robot must at no times be used without supervision of a qualified operator if there are guests passers by or other people unfamiliar with the robot within the working area The robot must never be operated in areas where there are staircases leading down elevated platforms or other po...

Page 7: ...dules during operation Objects or limbs may get squeezed or crushed if they get pulled in by a drive wheel or when the robot drives over them Great care is required while working on or with the robot to avoid such injuries or damages Depending on the application it can be necessary to design and mount protective covers around the drive modules 1 2 Operating Elements The locations of the basic oper...

Page 8: ...MENTS Fig 1 Basic control elements of the MPO 700 1 Emergency stop button 2 LC Display 3 Key switch 4 Computer access 5 Battery connector 6 Charging connector 7 Charging contacts 8 Antenna of the radio controlled emergency stop system 4 ...

Page 9: ...the automatic charging station 1 2 5 LC Display This display shows the most important status information A detailed description of the LCD can be found in LC Display page 14 1 2 6 Access to the On Board Computer All peripheral connections of the on board computer are accessible at the front of the platform 1 3 Mechanical Properties 1 3 1 Dimensions Fig 2 Dimensions of the MPO 700 5 ...

Page 10: ...ning Exceeding these ratings might cause malfunctions or damage the robot Description Units Value Storage temperature C 20 50 Operating temperature environmental temperature C 0 35 Payload kg 400 Maximum speed m s 0 9 Maximum bumpiness to pass over 0 25m s mm 15 Maximum bumpiness to pass over full speed mm 5 1 3 3 Positions of Sensors All distances are in millimetres measured relative to the platf...

Page 11: ...CHAPTER 1 MPO 700 1 3 MECHANICAL PROPERTIES Fig 3 Coordinate system of MPO 700 Fig 4 Positions of the laser scanners 7 ...

Page 12: ...rm s on board computer are connected to the same CAN bus and set to a baud rate of 1 MBaud The amplifiers settings might need to be changed to match the communication requirements of the used control software The configuration software Composer from Elmo Motion Control can be used to configure test and retune all motor amplifiers Each amplifier can be connected to a COM port 57600 Baud no parity o...

Page 13: ...ver the battery should be supported and fixed in position by wooden bars or other appropriate means 1 4 2 Unpacking the Robot If the robot is shipped in the original transport box only the lid should be removed Then all small components and the cushioning material can be taken out Once the robot is free of all cushioning it can be lifted out of the transport box This should be done by at least two...

Page 14: ...l and electronic components 1 4 5 Shipping with AGM Battery If the key switch was removed there is no risk of the robot being turned on during the transport or the battery being discharged Tip To eliminate every risk when shipping the robot as airfreight it is recommended to disconnect the battery prior to shipping The AGM batteries are leak proof and approved for airfreight 1 4 6 Shipping with Li...

Page 15: ...tee a satisfying operation the platform should be checked and cleaned regularly Information on how to clean the robot and its sensors can be found in Maintenance page 30 1 5 2 Omni Drive Modules In order to optimise the performance of the omnidirectional platform and to maximise its life expectancy please mind the following Always treat the mobile platform very carefully Do not overload the platfo...

Page 16: ...can find information about taking out of service and about recycling here page 32 1 7 Legal Notes The general legal notes can be found at Legal Notes page 33 1 7 1 EU Declaration of Conformity This product fulfils all relevant directives of the European Union 1 7 2 RoHS Information As non road mobile machinery our mobile robots are explicitly exempted from the scope of the RoHS directive 2011 65 E...

Page 17: ...d for about one second and then release again The message in the LCD display should change if the robot can be moved again 2 1 3 Shut down Turn the key counter clockwise towards position I for five seconds to initiate the shutdown which will happen within 30 seconds In this time the platform software if running terminates and shuts down the operating system In case the on board computer is shut do...

Page 18: ...fety system by turning the key switch clockwise for about one second SCANNER STOP An obstacle has been detected within the laser scanner s safety field As soon as the obstacle has been removed the safety system will be reset automatically If a Flexi Soft safety controller is installed all stops are indicated with this message CHARGING The robot is currently charging its batteries SHUTDOWN IN XXs T...

Page 19: ... of the batteries Due to the batteries characteristics the actual battery voltage may be higher than the platform s rated main voltage Nominal voltage Shut down Working range Charging 24 V 22 V 23 V 25 V 25 V 29 V 48v 44 V 46 V 52 V 52 V 59 V 2 2 1 4 Temperature T 20C This is the temperature in C inside the platform measured at the RelayBoard 2 2 1 5 Uptime 00d 00h 02m 37s The bottom line shows th...

Page 20: ...ulting in high weight for a given capacity and a limited number of charge discharge cycles Their capacity will reduce over time until at some point approximately after two years of use the robot s available uptime is no longer sufficient and the batteries need to be replaced There are several measures to prolong the life of AGM batteries and to save costs and resources Recharge the robot whenever ...

Page 21: ... of the mobile robot consists of several batteries connected in series and or in parallel The resulting battery pack can be charged conveniently and safely by using the provided battery charger The battery charger needs a power supply of 230 VAC 50 Hz The charger must be placed in a dry environment Do not cover the housing so appropriate cooling is possible and avoid direct sunlight First connect ...

Page 22: ...be returned to certified recycling companies Please get in touch with Neobotix if you are unsure about how to recycle or dispose of used batteries 2 4 Charging Stations 2 4 1 Automatic Charging Station The automatic charging station is very robust and can easily be installed and integrated into the robot s program In order to allow a fast and trouble free docking there needs to be some free space ...

Page 23: ...arging station requires the same power supply as the external battery charger To allow automatic charging the battery charger inside the station needs to remain switched on at all times Despite the open contacts which the robot needs for charging there is no danger of electric shock or short circuiting due to the charger s control mechanism There will only be a current if the device has detected t...

Page 24: ...ion to an ordinary power outlet Before installing any batteries always make sure that the integrated battery charger is switched off The main power switch is located directly beside the power cable connector Batteries can only be charged as a complete set of two identical batteries with the same charge level Place the batteries onto the station s base plate between the aluminium profiles with the ...

Page 25: ...CHAPTER 2 GENERAL HARDWARE INFORMATION 2 4 CHARGING STATIONS Fig 2 Position of the main power switch X 21 ...

Page 26: ...839 4 429661 532 412 10 pins 2 rows 281839 5 429673 532 428 12 pins 2 rows 281839 6 429685 532 434 Crimp contacts TE Connectivity Farnell RS Components AWG 28 24 182734 2 429715 532 456 In Neobotix products the pin assignment of the HE14 connectors is as shown below 2 5 2 Würth Elektronik MPC4 Please check the Würth Elektronik online catalogue3 for details on the MPC44 3 https www we online de web...

Page 27: ...22 Crimp contacts Würth Elektronik AWG 24 18 64900613722 In Neobotix products the pin assignment of the MPC4 connectors is as shown below 2 5 3 Würth Elektronik MPC3 Please check the Würth Elektronik online catalogue5 for details on the MPC36 5 https www we online de web de wuerth_elektronik start php 6 https www we online de katalog de em connectors wire to board wr_mpc3 23 ...

Page 28: ...6113322 12 662012113322 Crimp contacts Würth Elektronik AWG 24 20 66200113722 In Neobotix products the pin assignment of the MPC3 connectors is as shown below 2 6 Safety Instructions 2 6 1 General Safety Instructions This page contains general safety instructions and information that applies to all Neobotix robots 24 ...

Page 29: ...s strongly recommended to attend a training This online documentation is only provided as a work of reference when facing minor or common problems All other problems mistakes and difficulties can best be avoided by an in depth training for programmers and a proper briefing for operators Attention Always make yourself familiar with the robot its control and behaviour before starting your work or se...

Page 30: ...rgency stop and or to reset the safety system Additional safety devices can also be integrated into the mobile robot Please contact Neobotix if you plan to implement any special functions 2 6 4 Cooperating with the Robot 2 6 4 1 Close Proximity As long as the robot is not in full emergency stop a minimum distance should always be kept Direct contact to the active robot system is to be avoided Warn...

Page 31: ...ended to consult Neobotix in order to provide the appropriate training and information for all technicians and programmers The functions and safety of all modified robots have to be checked and ensured before bringing them into service Attention All warranties are void in case of any unauthorised or improper modification of the mobile robot system All responsibilities for the further operation of ...

Page 32: ...even cause the robot to leave the predefined paths 2 6 7 5 Electrical Overload The robot s on board power supply must not be overloaded Extreme overload may lead to overheating damages to the electrical installation and to short circuiting Please contact Neobotix before modifying the electrical system of the mobile robot 2 6 7 6 Modifications The robot must always be turned off and disconnected fr...

Page 33: ...ng required from the Customer Mobile manipulators are very complex robot systems The applications in which they will be used could not be foreseen in detail during the development of the robot Therefore beside any modifications needed for certain research work or experiments some very basic tasks must be completed before the mobile manipulator can be used safely An assessment of risks must be perf...

Page 34: ...able also may reduce the robot s capability to safely discharge electrostatic charge 2 8 1 2 Sensors Cleaning the various sensors is indispensable to assure that the robot can move safely and swiftly through its environ ment Attention Be very careful not to scratch the cover of the laser scanner or the membranes of the ultrasonic sensors Damaging these components might cause severe malfunctions 2 ...

Page 35: ...y use replacement parts with features and properties identical to those of the original parts Always mount all covers and hull parts properly and securely after finishing your work Make sure to reconnect and fix all electrical connections especially shieldings and earthing straps 2 8 2 4 Batteries The batteries need to be checked regularly and have to be replaced after some time Additional informa...

Page 36: ... risk of injuries or damages to components that are to be reused and proper sorting of parts according to materials and way of recycling More information on qualified personnel can be found at Qualified Personnel page 31 2 10 2 Recycling 2 10 2 1 Reusable components Many components of the mobile robot e g the servo motors and the amplifiers have a very long life expectancy and will most probably s...

Page 37: ...composing However inaccuracies or omissions might occur Please inform Neobotix in case you notice any The Neobotix GmbH cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and manual without prior notice Neobotix makes no warranty of any kind with regard to the material contained within this document including but not limited t...

Page 38: ...ctly flat These modules are intended for research and experiments and need to be modified and completed by the customer Several important issues must be considered when working with them The Omni Drive Module is a partly completed machine and not ready for immediate operation The drive amplifiers have been configured with general purpose settings Some of these settings might need to be adjusted ac...

Page 39: ...o amplifier each Whistle 10 60 from Elmo Motion Control mounted to a common printed circuit board One of the motors drives the mod ule s driving wheel while the other motor rotates the wheel around its vertical axis Both motors can rotate infinitely without mechanical boundaries thus allowing an omnidirectional robot to move continuously and without the need to re align the wheels due to any limit...

Page 40: ...mni Drive Modules This configuration ensures high stability for smaller robots avoids static indeterminacy and allows fully omnidirec tional movement All three wheels must be aligned correctly at all times to avoid jamming or slippage Please mind that the angle between the wheels must change according to the movement s centre of rotation 3 1 2 3 4 Omni Drive Modules This configuration is most comm...

Page 41: ...tly differ from module to module Therefore the control software must implement an adjustable offset for each orientation drive Tip Proper functioning of the overall drive system can only be achieved by aligning all wheels correctly at all times 3 1 3 3 Digital and Analogue I Os Each drive amplifier provides six digital inputs two digital outputs and one analogue input Three digital inputs and one ...

Page 42: ... ventilation or other means of cooling might become necessary The drive module must be kept clean at all times Exposure to excessive dirt or moisture may lead to damage of the ball bearings or other moving parts Neobotix cannot be held responsible for damages caused by dirt or moisture 3 2 2 Improper Usage Warning Using a vehicle based on the Omni Drive Modules for any kind of passenger transporta...

Page 43: ...designed to be mounted under a vehicle but into it The base plate of your vehicle must be in between the wheel carrier assembly and the gearbox housing A U shaped cut out of 60 mm to 70 mm width is recommended for the vertical axle of the wheel carrier assembly 3 3 2 Mounting Components onto the Module If all Omni Drive Modules are mounted to a common base plate additional components may be placed...

Page 44: ...CHAPTER 3 OMNI DRIVE MODULE 3 4 ELECTRICAL INSTALLATION Fig 1 Dimensions of the Omni Drive Module 40 ...

Page 45: ...CHAPTER 3 OMNI DRIVE MODULE 3 4 ELECTRICAL INSTALLATION Fig 2 Bottom view of the Omni Drive Module 41 ...

Page 46: ...CHAPTER 3 OMNI DRIVE MODULE 3 4 ELECTRICAL INSTALLATION Fig 3 Top view of the Omni Drive Module 42 ...

Page 47: ...on drive is powered directly from the amplifiers PCB If different voltages are used they must be connected to a common ground Attention The ground line of the digital input is by default connected to the common ground of the amplifier power supply In case independent supply voltages are required please contact Neobotix Use the following components for the power supply of the switch in case you are...

Page 48: ...or Please use the following components for the CAN bus connection Housing TE Connectivity HE14 receptacle double row 8 circuits 281839 4 Contacts TE Connectivity HE14 crimp terminal female 28 24 AWG 182734 2 The pin assignment is as follows Pin Function 1 5 GND 2 6 CANL 3 7 CANH 4 8 Shield If the CAN bus ends at one of the Omni Drive Modules a terminating resistor of 120 Ω has to be activated Plea...

Page 49: ...ase keep in mind that the limiting resistor has to be bridged if the default signal level of 5 V is used The digital input 1 of the orientation drive amplifier is connected to the output of the position switch and cannot be used for customised functions Tip The ground line of the digital inputs of the orientation drive amplifier is by default tied to the common ground of the amplifier power supply...

Page 50: ...d the limiting resistor 12 I3 Digital input 3 mind the limiting resistor 3 4 3 1 Motion Monitoring On request the connectors can be prepared to provide direct access to the encoder signals of the traction and or orientation motor from outside This option will change the pin assignment as follows Pin Function Description 1 O Emitter contact of the optocoupler of digital output 1 2 B Channel A of th...

Page 51: ...ce software Composer which is provided for free download from the homepage of the manufacturer Elmo Motion Control The latest version can be found at https www elmomc com product composer It is recommended to connect the computer that runs the Composer to the amplifier by a standard RS 232 serial connection COM port The appropriate configuration cable can be supplied on request The drive amplifier...

Page 52: ... the amplifier Note Please be careful to actually connect to the amplifier which you currently want to access Choose Open Communication Directly to open the communication settings dialogue After selecting RS 232 as inter face and clicking Properties you can select the COM port that you are using Please select a baud rate of 57600 Bit Per Second and click Connect The dialogue should close and the c...

Page 53: ...it sometimes happens that only the power supply is connected to the next module while the configuration cable is still plugged to the previous module Baud rate The baud rate of the serial connections has been changed to 57 6 kBaud to make working with the modules more convenient The default baud rate of the Composer is only 19 2 kBaud COM port Try other COM port numbers If a USB to serial converte...

Page 54: ... file and click Download in the open dialogue In case the current interface differs from the settings stored in the file you will need to open the properties dialogue by clicking Change in the Communication Info area of the file open dialogue After the connection has been established successfully the configuration is downloaded to the volatile memory of the amplifier To save the configuration perm...

Page 55: ...vanced Settings The motor must be deactivated for some settings to be applied Use the button Stop Motor Off to deactivate the motor 3 5 3 1 Acceleration and Deceleration The maximum permitted acceleration and deceleration can be set by editing the two according fields in the tab Profile of the Smart Terminal and clicking Apply These values are the limiting values and will be used by the internal c...

Page 56: ...to the given Position Simply click the Go button to start the motion and Stop to set the velocity back to zero The Composer also offers a function to record high definition measurements of the motor s movements and to plot these data graphically Please contact Neobotix or Elmo Motion Control if you need further information on this topic 3 6 Maintenance The Neobotix Omni Drive Module does not requi...

Page 57: ...CHAPTER 3 OMNI DRIVE MODULE 3 7 TECHNICAL DATA 3 7 Technical Data 3 7 1 Dimensions Dimensional drawings of the Omni Drive Module can be found in chapter Mounting page 39 3 7 2 Board Layout 53 ...

Page 58: ...rmation about taking out of service and about recycling here page 32 3 9 Legal Notes The general legal notes can be found at Legal Notes page 33 3 9 1 Declaration of Incorporation This product is a partly completed machinery and sold without CE marking This partly completed machinery must not be put into service until the final machinery into which it is to be incor porated has been declared in co...

Reviews: