WARNING

 Read carefully and understand all ASSEMBLY AND 

OPERATION

INSTRUCTIONS before operating. Failure to follow the safety 

rules and other basic safety

precautions may result in serious personal injury.

Item #37001 

Summary of Contents for 37001

Page 1: ...AVE THESE INSTRUCTIONS WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Item 37001 ...

Page 2: ...s ca gov Page 2 of 12 T an you for c oosin a Nature Po er Pro uct This product is designed for certain applications only The distributor cannot be responsible for issues arising from modification We strongly recommend this product not be modified and or used for any application other than that for which it was designed If you have a question relative to a particular application o not use the produ...

Page 3: ...unplug unit from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 7 For the most effective use place the power inverter on a flat surface 8 Do not place the inverter on or near heating vents radiators or other sources 9 Do not place the inverter in direct sunlight The ideal air temperature for operation is between 50 and 80 F 10 Only connect the p...

Page 4: ...verter 2 Locate the chassis ground screw on the back of the inverter 3 Remove the outer nut and loosen the first locking washer 4 Attach the grounding wire s ring connector to the ground terminal of the inverter 5 Tighten the locking washer securely Then replace the other nut and tighten it securely The inverter and power source must be in the OFF mode IMPORTANT Make sure to connect your inverter ...

Page 5: ...NG INVERTER CABLES TO THE INVERTER 1 Locate the Positive and Negative terminals on the inverter 2 From the POSITIVE RED and the NEGATIVE BLACK terminals remove 3 Place the POSITIVE RED ring connector onto the POSITIVE RED inverter terminal Place the NEGATIVE BLACK ring connector onto the NEGATIVE BLACK inverter terminal 4 top of each ring connector Put a nut over these and tighten NOTE Please use ...

Page 6: ...nverter is receiving power 4 Switch the inverter s ON OFF switch to the OFF O position Then the GREEN LED may flash briefly and or the internal speaker may make a brief beep This is normal 5 Make sure the device to be operated is turned OFF 6 Plug the device into the inverter s AC outlet 7 Switch the inverter s ON OFF switch to the ON I position 8 Turn the device on 9 To disconnect reverse the abo...

Page 7: ...is on Keep the car running at all times when using the inverter The actual length of time the inverter will function depends on the age and condition of the battery and the power demand being placed by the device being operated with the inverter When possible recharge your batteries when they are not more than 50 discharged This gives the batteries a much longer life cycle than recharging when the...

Page 8: ...e or replace the battery 2 When the power input from the vehicle s battery exceeds 16 volts high voltage protection occurs The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the inverter Use a higher capacity inverter or lower rated device 4 The thermal resistor exceeds 80 C 176 F Allow the inverter to cool Do not block the cooling slots or...

Page 9: ...ch use ensure that all of the 4 inverter s components are in place and in good working condition 2 After use and before performing maintenance unplug and disconnect the inverter 3 Use a clean dry cloth to wipe external surfaces of the inverter s case Servicing does not require opening the unit as there are no user serviceable parts All servicing should be performed 5 Store inside in a cool dry pla...

Page 10: ...replace the battery Use a higher capacity inverter or decrease the load or device on the inverter Allow inverter to cool Check for adequate ventilation Reduce the load on the inverter to the rated continuous power output Alarm sounds continuously Input voltage is below 10 volts Poor or weak battery connection Recharge or replace the battery Check for poor connection to battery Make sure connection...

Page 11: ...aveform Efficiency typical Modified sine wave 86 Typical No Load Current at nominal input voltage 0 4 ADC Input overvoltage shutdown 15 5 0 5 VDC Input undervoltage alarm 10 5 0 5 VDC Input low voltage shutdown 10 0 0 5 VDC Output power overload shutdown level 1300 300 W Input fuse 3x40 A AC receptacles Two NEMA 5 15 USA USB port One 5V 2A Battery cables 7AWG 2 39 3 in Ground wire 15AWG 1 39 3 in ...

Page 12: ... be returned to the authorized location at the purchasers expense A dated proof of purchase is required to receive warranty service Once received at authorized location and defect proves to be the result of defective material and workmanship the defective part or unit will be replaced at warrantors option and returned to the original purchaser at warrantors expense No refunds will be granted by th...