background image

National Comfort Products

A Division of National Refrigeration and Air Conditioning Products, Inc.

 

539 Dunksferry Road   •   Bensalem, PA 19020-5908

(800) 523-7138

   •   Fax (215) 639-1674

www.nationalcomfortproducts.com

 

HEATING & A/C EQUIPMENT

NATIONAL

COMFORT

PRODUCTS

®

Go Thru-the-Wall

HEATING & A/C EQUIPMENT

NATIONAL

COMFORT

PRODUCTS

®

Thru-the-Wall Comfort for all types of Multi-Family Construction

Please read the entire installation guide  
before starting the installation.
All phases of this installation must comply  
with National, State and Local codes.

Electric Heat Kit

Please fill in the following information and file it 

for future reference.

MODEL NO.______________________________

SERIAL NO.______________________________

INSTALL DATE ___________________________

Installation  

Guide

Summary of Contents for CPE41200U

Page 1: ...PMENT NATIONAL COMFORT PRODUCTS Thru the Wall Comfort for all types of Multi Family Construction Please read the entire installation guide before starting the installation All phases of this installation must comply with National State and Local codes Electric Heat Kit Please fill in the following information and file it for future reference MODEL NO ______________________________ SERIAL NO ______...

Page 2: ...2 Installation Guide Electric Heat Kit ...

Page 3: ...ERENCE Important This document is customer property and is to remain with this unit Safety Warnings page 4 Comfort Pack Installation page 6 Comfort Pack Heater Specifications page 8 Multi Family Air Handler Installation page 9 Multi Family Air Handler Heater Specifications page 12 Heater Wiring Diagrams page 13 Table of Contents ...

Page 4: ...RE THAN ONE DISCONNECT SERVICING THE UNIT A MEANS OF STRAIN RELIEF AND CONDUCTOR PROTECTION MUST BE PROVIDED AT THE SUPPLY WIRE ENTRANCE INTO CABINET USE COPPER CONDUCTORS ONLY INSTALLATION MUST FOLLOW NATIONAL ELECTRIC CODE AND OTHER APPLICABLE CODES If this appliance is installed in an enclosed area such as a garage or utility room with any carbon monoxide producing appliance ensure the area is ...

Page 5: ...er access panel from the cabinet 2 Remove the heater cover plate from the unit Keep the two screws to reuse in the next step 3 Insert the heater banks into the opening and secure with four screws additional screws can be found in accessories kit 4 Mount the circuit breaker s to the bracket at the front of the furnace section ...

Page 6: ...Power and Control wiring harnesses from the Heat Kit to their associated connectors Then connect the external power wiring to the free end of the Heat Kit circuit breaker s Refer to the Unit Installation Manual for instructions and complete wiring diagram 7 Reinstall the upper access panels and install the corresponding breaker patch plate from the accessories kit 8 Remove the filter access panel ...

Page 7: ...S 208 230 C XFMER TRANSFORMER FACTORY SET POINT IS 230V FIELD ADJUSTMENT REQUIRED FOR 208V APPLICATION DISCONNECT NON FUSED OPTIONAL FUSED OR L2 L1 G BLACK WHITE ORANGE BLUE GREEN WHITE BLACK GREEN WHITE BLACK RED BLACK BLACK WHITE 0 1 24V COIL 4 2 6 8 0 1 24V COIL 4 2 6 8 0 1 24V COIL 4 2 6 8 HL HTR1 HTR2 HL HTR3 HL WHITE WHITE BLACK BLACK BLACK FL FL FL WHITE 30A BR 60A BR HR2 HR3 HR1 L2 L1 L2 L...

Page 8: ...5 CPEHK 05 A 5 kW 16 000 13 100 23 3 21 4 28 4 26 0 30 30 CPEHK 07 A 7 kW 22 400 18 300 31 6 28 8 38 8 35 3 40 40 CPEHK 10 A 10 kW 32 000 26 000 43 7 39 7 53 8 48 9 55 50 CPEHK 15 A 15 kW 47 800 39 200 64 0 58 1 79 2 71 9 80 75 CPE41240U CPEHK 03 A 3 kW 10 900 8 900 17 8 16 5 21 3 19 0 25 25 CPEHK 05 A 5 kW 16 000 13 100 24 2 22 3 29 3 26 9 30 30 CPEHK 07 A 7 kW 22 400 18 300 32 5 29 7 39 7 36 2 4...

Page 9: ...nels from the cabinet 3 Remove the heater cover plate from the unit Keep the four screws to reuse in the next step 4 Insert the heating banks into the opening and secure with four screws 2 Disconnect and remove the air handler s existing power wire harness TO EXTERNAL POWER CONNECTION TO TRANSFORMER ...

Page 10: ...al splitter and jumper wire will be required 5 Move the control board from the front board bracket to the bracket on the heat kit C W1A W1B W2 Y COOL HEAT CONTACTOR COILS FAN OUTPUTS C R R C Y G W2 W1 TO THERMOSTAT CB RED HIGH YELLOW MED HIGH BLUE MED BLACK MED LOW ORANGE LOW FAN SPEEDS 8 Connect the Power and Control wiring harnesses from the Heat Kit to their associated connectors in the Air Han...

Page 11: ...AX VOLTAGE VOLTAGE MIN MAX PH HZ PSIG KPA KPA PSIG PRESSION STATIQUE EXTERNE MAX 0 5 WC MINIMUM SPACING TO COMBUSTIBLE SURFACES 0 0 ESPACEMENT MINIMUM AUX SURFACES COMBUSTIBLES 0 0 MAXIMUM OUTLET AIR TEMPERATURE 200 F TEMPÉRATURE MAXIMALE DE L AIR DE SORTIE 200 F USE COPPER CONDUCTORS ONLY MOTORS ARE THERMALLY PROTECTED UTILISER UNIQUEMENT DES CONDUCTEURS EN CUIVRE LES MOTEURS SONT PROTÉGÉS THERMI...

Page 12: ... 900 17 7 16 5 22 1 20 6 25 25 CPEHK 05 A 5 kW 16 000 13 100 24 2 22 3 30 2 27 9 35 30 CPEHK 07 A 7 kW 22 400 18 300 32 4 29 7 40 5 37 2 45 40 CPEHK 10 A 10 kW 32 000 26 000 44 5 40 6 55 6 50 8 60 60 CPEHK 15 A 15 kW 47 800 39 200 43 17 22 85 39 36 20 98 54 0 28 6 49 2 26 2 60 30 50 30 Heater Specification Air Handler Unit Compatibility List is subject to change without notice Multi Family Air Han...

Page 13: ...13 Installation Guide Electric Heat Kit Wiring Diagrams Wiring Diagrams CPEHK 03 05 07 10 A CPEHK 15 A ...

Page 14: ...14 Installation Guide Electric Heat Kit Notes ...

Page 15: ...15 Installation Guide Electric Heat Kit Notes ...

Page 16: ...ATING A C EQUIPMENT NATIONAL COMFORT PRODUCTS National Comfort Products A Division of National Refrigeration Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 1 800 523 7138 Fax 215 639 1674 www nationalcomfortproducts com ...

Reviews: