background image

USER GUIDE for 

RPR 530 SERIES

RADIO PAGERS

9261-0366 issue 4

Summary of Contents for RPR 530 SERIES

Page 1: ...USER GUIDE for RPR 530 SERIES RADIO PAGERS 9261 0366 issue 4...

Page 2: ...two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Unauthorised modifica...

Page 3: ...oor coverage where the signal reception is not always possible SAFETY As a normal safety precaution your pager should not be carried into areas where explosive gases or dusts etc may be present Intrin...

Page 4: ...CONTROLS AND DISPLAY DISPLAY ALERT LAMP GRIPTITE CLIP MUTE BUTTON OFF BUTTON ON CANCEL MEMORY RECALL OCR BUTTON...

Page 5: ...OFF To switch off your pager press the recessed Off button RECEIVING A TONE ALERT CALL The red alert lamp flashes an alert tone sounds not in mute mode and the pager will vibrate if this option is fi...

Page 6: ...splay message except that a few seconds after the alerting starts the speech channel automatically opens and you hear a spoken message The speech channel is closed after a predetermined time or can be...

Page 7: ...w messages are stored in memory Out of Range The pager is not within range of receiving calls Low Battery Battery is low and needs replacing or recharging if rechargeable batteries are being used HH M...

Page 8: ...ge erases the oldest one Each call is designated new status when first received This is removed by cancelling alert sequence press the OCR button during the alert period or by accessing the call from...

Page 9: ...o confirm this change Release the mute button To return to normal alert mode press and hold the mute button until you hear two pips followed by a single pip and the display has changed from Mute to On...

Page 10: ...utton press the mute button once then release both buttons The display shows the directory of Alpha messages together with the assigned beep code and two digit message number After the first message i...

Page 11: ...two minutes The pager vibrates if the option is fitted Press the OCR button to stop extended alert and display the most recently received message Escalating Alert The escalating alert mode allows the...

Page 12: ...ing buzz Pressing OCR when the pager is out of range causes a warning buzz to be heard Time of Day The display shows current Time of Day as one of the standard messages Not applicable to 530T variants...

Page 13: ...GRIPTITE CLIP The pager is fitted with a detachable Griptite clip which secures firmly to thick or thin material To tighten the clip move the slider on the clip towards the top of the pager...

Page 14: ...ager is not to be used for a month or more you should remove your battery BATTERY REPLACEMENT A low battery indication is triggered when the battery voltage drops below a predetermined level You will...

Page 15: ...ld the pager as shown and insert a small pointer in the hole 3 While pressing this pointer down slide the battery door cut out with your thumb 4 Remove the old battery fit a new one with terminal faci...