manualshive.com logo in svg
background image

Temposonics

®

 GB-Series

Brief Instructions

Temposonics

®

Magnetostrictive Linear Position Sensors

Содержание Temposonics GB Series

Страница 1: ...Temposonics GB Series Brief Instructions Temposonics Magnetostrictive Linear Position Sensors...

Страница 2: ...e in explosion hazardous areas 5 2 5 Warranty 5 2 6 Return 5 2 7 Maintenance removal 5 3 Identification 6 3 1 Temposonics GB Series GB J GB K GB N GB S rod sensor with pressure fit flange 6 3 2 Tempos...

Страница 3: ...escribed product or connected devic es In this documentation safety information and warnings to avoid danger that might affect the life and health of operating or service personnel or cause material d...

Страница 4: ...Forseeable misuse Consequence Wrong sensor connection The sensor does not work properly or will be destroyed Operate the sensor out off the operating temperature No signal output The sensor can be da...

Страница 5: ...Warranty MTS Sensors grants a warranty period for the Temposonics position sensors and supplied accessories relating to material defects and faults that occur despite correct use in accordance with t...

Страница 6: ...dels available at www mtssensors com GBS0850MD601A0SC 4 20 mA FNr 1601 0376 1601037616010376160103761601 Sensor model Stroke length e g 850 mm Connection type Output version Part no Output Production...

Страница 7: ...maged A false measurement is also possible Longer rods require evenly distributed mechanical support over the entire length Use an U magnet for measurement Typical use of magnets Ring magnet Rotationa...

Страница 8: ...Magnet Magnet 1 2 3 3 A B Magnetic material 1 Null zone depends on sensor model 2 Distance between position magnet and any magnetic material 15 mm 3 Non magnetic spacer 5 mm Recommendation 8 mm Magnet...

Страница 9: ...leads as short as possible Keep the earth connection as short as possible with a large cross section Avoid ground loops With potential differences between machine and electronics earth connections no...

Страница 10: ...0 for output A4 in order code Signal power supply M16 male connector Pin Current 1 2 3 6 5 4 View on sensor 1 4 20 mA 2 DC Ground 3 20 4 mA 4 DC Ground 5 24 VDC 15 20 6 DC Ground 0 V Connect the rst o...

Страница 11: ...Color Function GY Data PK Data YE Clock GN Clock BN 24 VDC 15 20 WH DC Ground 0 V D84 Signal power supply M12 male connector A coded Pin Function 1 2 4 6 8 3 5 7 View on sensor 1 Clock 2 Clock 3 Data...

Страница 12: ...s I 12 I The sensor is also available with Bluetooth connection For more information see document Programming Configuration via Bluetooth Document part number for GB Series analog 551595 Document part...

Страница 13: ...rs com www mtssensors com MTS Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Co...