Rev. 1.0

11/28/2017

SHANGHAI AMP & MOONS

AUTOMATION CO.,LTD.

STF-D/IP

Stepper Motor Drive

Hardware Manual

STF03-D    STF05-D

STF06-D    STF10-D

STF03-IP   STF05-IP

STF06-IP   STF10-IP

Summary of Contents for STF-D series

Page 1: ...Rev 1 0 11 28 2017 SHANGHAI AMP MOONS AUTOMATION CO LTD STF D IP Stepper Motor Drive Hardware Manual STF03 D STF05 D STF06 D STF10 D STF03 IP STF05 IP STF06 IP STF10 IP ...

Page 2: ...ing the Motor 16 3 Inputs and Outputs 16 3 1 Digital Inputs 17 3 1 1 X1 X2 X3 and X4 Digital Inputs 17 3 1 2 X5 X6 X7 and X8 Digital Inputs 18 3 2 Digital Outputs 19 3 2 1 Y1 Y2 and Y3 Digital Outputs 19 3 2 2 Y4 Digital output 20 4 Mounting the Drive 21 5 Reference Materials 22 5 1 Drive Mechanical Outlines 22 5 2 Technical Specifications 23 5 3 Recommended Motor 24 5 4 Torque Curves 27 5 5 Number...

Page 3: ...s Programmable filed bus controlled stepper motor drive in a compact package Operating DC voltage range STF03 12 48V STF05 24 48V STF06 12 48V STF10 24 70V Dual Port RJ45 connector for drive configuration and Ethernet communication based on the widely used 100BASE TX cabling system and with a baud rate of 100Mbps full duplex Supported communication modes Ethernet UDP TCP EtherNet IP eSCL Support MOO...

Page 4: ...ifier High Speed Input Optical Isolation Input Optical Isolation Digital Filter Software Filter Digital Filter Software Filter Output Optical Isolation Single Ended Input Isolation X1 X1 X2 X2 X3 X3 X4 X4 X5 X6 X7 X8 XCOM Y1 Y2 Y3 YCOM Software Filter Motor Ethernet Ethernet IP Address LED STF D IP Block Diagram Power Supply STF03 12 48VDC STF05 24 48VDC STF06 12 48VDC STF10 24 70VDC S1 Y4 Y4 ...

Page 5: ...n injury and damage to persons and machinery All technical information concerning the installation requirements must be strictly adhered to It is vital to ensure that all system components are connected to earth ground Electrical safety is impossible without a low resistance earth connection This product contains electrostatically sensitive components that can be damaged by incorrect handling Foll...

Page 6: ... Power Supply for help in choosing the right one A compatible stepper motor please see the section below entitled Recommended Motor A small flat blade screwdriver for tightening the connectors screw included A PC running Microsoft Windows XP Vista Windows 7 Windows 8 Windows 10 32 bit or 64 bit operation system A CAT5 cable for Ethernet daisy chain connection included Optional I O cable Install STF...

Page 7: ...y clicking Start All programs MOONS STF Configurator Connect the drive to the power supply Connect the motor to the drive Apply power to the drive The software will recognize the drive and display the model and firmware version At this point it is ready for use The connectors and other points of interest are illustrated below Grounding Screw Drive Status Disply LED IP Address Switch Motor Connector...

Page 8: ...dress and subnet mask of your PC select Start All Programs Accessories Command Prompt Then type ipconfig and press Enter You should see something like this If your PC s subnet mask is set to 255 255 255 0 a common setting known as a Class C subnet mask then your machine can only talk to another network device whose IP address matches yours in the first three octets The numbers between the dots in a...

Page 9: ...775 To send and receive commands using TCP use port number 7776 You ll need to know this when you begin to write your own application You will also need to choose an open unused port number for your application Our drive doesn t care what that is when the first command is sent to the drive the drive will make note of the IP address and port number from which it originated and direct any responses t...

Page 10: ... of the default addresses are acceptable for your network you can enter a new table of IP addresses using Configurator If your network uses addresses starting with 192 168 0 the most common subnet you will want to choose an address from switch settings 4 through E Another common subnet is 192 168 1 If your network uses addresses in this range the compatible default selections are 1 2 and 3 If your ...

Page 11: ...work and powered on select Drive Discovery from the Drive menu You will see a dialog such as this Normally Drive Discovery will only detect one network interface card NIC and will select it automatically If you are using a laptop and have both wireless and wired network connections a second NIC may appear Please select the NIC that you use to connect to the network to which you ve connected your d...

Page 12: ...es Select Change adapter settings 4 You should see an icon for your network interface card NIC Right click and select properties a Scroll down until you see Internet Properties TCP IP Select this item and click the Properties button b On Windows 7 and Vista look for TCP IPv4 5 Select the option Use the following IP address Then enter the address 10 10 10 11 This will give your PC an IP address tha...

Page 13: ...y Network Places and select properties b On Windows 7 click Computer Scroll down the left pane until you see Network Right click and select properties Select Change adapter settings 5 You should see an icon for your newly instated NIC Right click again and select properties a Scroll down until you see Internet Properties TCP IP Select this item and click the Properties button b On Windows 7 and Vi...

Page 14: ...ange from 12 48VDC STF05 accepts DC voltage range from 24 48VDC STF06 accepts DC voltage range from 12 48VDC STF10 accepts DC voltage range from 24 70VDC Warning DO NOT reverse the wires NOTE DO NOT apply power until all connections to the drive have been made V J1 V Power Connector Ensure a proper earth ground connection by using the screw on the left side of the chassis To Earth Ground Please re...

Page 15: ...lated power supply make sure the no load voltage of the supply does not exceed the maximum input voltage 53VDC STF10 If a regulated power supply is used and that is near the driver maximum voltage of 75VDC a voltage clamp may be required to prevent the voltage over 75VDC which will occurs a overvoltage fault When using an unregulated power supply make sure the no load voltage of the supply does no...

Page 16: ...OONS motor please refer to your motor specs for wiring information 3 Inputs and Outputs STF series drive inputs and outputs include 8 optically isolated digital inputs 5 24VDC for high level voltage 4 optically isolated digital outputs maximum voltage 30V maximum sinking or sourcing current 100mA 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 X1 X2 X3 X4 X5 X7 Y1 Y3 Y4 XCOM YCOM X1 X2 X3 X4 X6...

Page 17: ...al purpose input X3 can be used as CW limit input or general purpose input X4 can be used as CCW limit input or general purpose input Please use STF Configurator software for X1 X2 X3 and X4 function configuration Following graphs shows some common connection methods for the inputs STF Drive Switch or Relay closed logic Low X1 2 3 4 X1 2 3 4 5 24 VDC Power Supply STF Drive NPN Output X1 2 3 4 X1 2 3...

Page 18: ...stem but if you want to connect a relay or mechanical switch to the input you must need a power supply XCOM is an electronics term for a single ended signal connection to a common voltage If you are using a sourcing PNP input signals you need to connect XCOM to the ground power supply if you are using a sinking NPN input signals the XCOM need to be connected to the power supply Use STF Configurato...

Page 19: ...al purpose output Please use STF Configurator software for Y1 Y2 and Y3 function configuration Following graphs shows some common connection methods for the outputs NOTE Do not connect the outputs to more than 30VDC power supply And the current of each output terminal must not exceed 100mA Connecting a sinking output Connecting a sinking output with PLC s input Driving a relay STF Drive 5 24 VDC Pow...

Page 20: ... for the outputs NOTE Do not connect the outputs to more than 30VDC power supply And the current of each output terminal must not exceed 100mA Y4 Y4 Y4 Y4 Y4 Y4 Y4 Y4 C L P IN COM PLC COM IN relay STF Drive STF Drive STF Drive STF Drive Connecting a sinking output Connecting a sinking output with PLC s input Connecting a sourcing output with PLC s input Load 5 24VDC Power Supply 5 24VDC Power Supp...

Page 21: ... metal surface that will help conduct heat away from the chassis If this is not possible forced airflow from a fan maybe required to prevent the drive from overheating Never use the drive in a place where there is no air flow or the surrounding air is more than 40 Never put the drive where it can get wet or where metal or other electrically conductive particle particles can get on the circuity Alway...

Page 22: ...820 9661 5 Reference Materials 5 1 Drive Mechanical Outlines Unit mm Model STF05 D STF05 IP STF10 D STF10 IP 4 5 23 5 86 6 61 8 49 8 3 5 7 8 16 93 100 157 6 93 Unit mm Model STF03 D STF03 IP STF06 D STF06 IP 4 5 4 5 142 5 11 6 78 2 50 17 29 122 122 129 ...

Page 23: ...ipple Smoothing Allows for fine adjustment of phase current waveform harmonic content to reduce low speed torque ripple in the range of 0 25 to 1 5 rps Auto Test Auto Setup Auto test and setup at power on ie motor resistance and capacitance to optimize your system performance Non Volatile Storage Configurations are saved in FLASH memory on board the DSP Operation Mode Step direction CW CCW pulse A B...

Page 24: ...M23HS0421 01 Single Shaft 4 41 0 6 4 5 135 0 42 AM23HS0421 02 Double Shaft 4 AM23HS2450 01 Single Shaft 4 54 1 2 4 5 260 0 6 AM23HS2450 02 Double Shaft 4 AM23HS3455 01 Single Shaft 4 76 1 8 4 5 460 1 AM23HS3455 02 Double Shaft 4 AM23HS04A0 01 Single Shaft 4 39 0 82 2 2 120 0 4 AM23HS04A0 02 Double Shaft 4 AM23HS84A0 01 Single Shaft 4 55 1 5 2 2 220 0 6 AM23HS84A0 02 Double Shaft 4 AM23HSA4A0 01 Si...

Page 25: ...BR01 Brake Motor 4 2 118 2 3 390 1 2 AM24HS2402 BR01 Brake Motor 4 2 95 1 2 4 5 450 1 03 AM24HS5401 BR01 Brake Motor 4 2 126 2 5 900 1 6 AM34HD0404 BR01 Brake Motor 4 2 118 5 3 7 1100 2 2 AM34HD1404 BR01 Brake Motor 4 2 148 5 1850 3 3 AM34HD2403 BR01 Brake Motor 4 2 177 5 7 1 2750 4 4 Encoder type motor Model Features Lead number Length mm Holding Torque N m Current A Rotor Inertia g cm2 Mass Kg M...

Page 26: ... 5 42000 1 44 AM23HS84B0 PG05 5 speed reducer motor 4 128 5 7 5 4 5 5375 1 43 AM23HS84B0 PG10 10 speed reducer motor 4 128 5 15 4 5 21500 1 43 AM23HS84B0 PG20 20 speed reducer motor 4 141 5 30 4 5 86000 1 64 AM23HSA4B0 PG05 5 speed reducer motor 4 150 5 11 5 4 5 9125 1 83 AM23HSA4B0 PG10 10 speed reducer motor 4 150 5 23 4 5 36500 1 83 AM23HSA4B0 PG20 20 speed reducer motor 4 163 5 46 4 5 146000 2...

Page 27: ...rostep 20000 steps rev Current 1 6A Peak AM11HS5008 Speed rps Torque mN m 150 120 90 60 30 0 0 10 20 30 40 50 Microstep 20000 steps rev Current 1 6A Peak AM14HYB401 Speed rps Torque mN m 150 120 90 60 30 0 0 10 20 30 40 50 Microstep 20000 steps rev Current 1 0A Peak AM17HD4452 Speed rps Torque mN m 250 200 150 100 50 0 0 10 20 30 40 50 Microstep 20000 steps rev Current 1 8A Peak AM17HD2438 Speed r...

Page 28: ... Speed rps 0 6 0 5 0 4 0 3 0 2 0 1 0 0 10 20 30 40 50 AM23HS0420 Microstep 20000 steps rev Current 2 2A Peak Torque N m 24V 48V Speed rps 1 2 1 0 8 0 6 0 4 0 2 0 0 10 20 30 40 50 AM23HS2449 Microstep 20000 steps rev Current 2 2A Peak Torque N m AM23HS3454 Speed rps 2 1 6 1 2 0 8 0 4 0 0 10 20 30 40 50 Microstep 20000 steps rev Current 2 2A Peak Torque N m Speed rps 0 6 0 5 0 4 0 3 0 2 0 1 0 0 10 2...

Page 29: ... 20000 steps rev Current 4 5A Peak 24V 48V 75V Torque N m Speed rps 2 4 2 1 6 1 2 0 8 0 4 0 0 10 20 30 40 50 AM24HS5401 Microstep 20000 steps rev Current 4 5A Peak 24V 48V 75V Torque N m Microstep 20000 steps rev Current 7 0A Peak AM34HD0404 24V 48V 75V Speed rps 3 2 5 2 1 5 1 0 5 0 0 10 20 30 40 50 m N e u q r o T AM34HD1404 Microstep 20000 steps rev Current 7 0A Peak Speed rps Torque N m 5 4 3 2...

Page 30: ...e Error solid green no alarm motor disabled flashing green no alarm motor enabled 1 red 2 green move while disabled 2 red 1 green CCW limit 2 red 2 green CW limit 3 red 1 green drive over temperature 3 red 2 green internal voltage bad 3 red 3 green blank Q segment 4 red 1 green over voltage 4 red 2 green under voltage 5 red 1 green over current 6 red 1 green open motor winding 7 red 1 green commun...

Page 31: ...501648 1000 Molex L 19 20 2 J1 1 50 5 Bus Communication Daisy Chain Cable Common Type Shielded Type Length 2012 030 2013 030 0 3m 2012 300 2013 300 3m 2012 030 is included in the drive package L L 8 1 8 1 RC 880 RC 880 is used to limit increase in power supply voltage when the motor is decelerating under load This is commonly referred to as regeneration RC 880 can clamp the regeneration and preven...

Page 32: ...65 66341198 Fax 65 66341138 Nanjing Room 1101 1102 Building 2 New Town Development Center No 126 Tianyuan Road Moling Street Jiangning District Nanjing 211106 P R China Tel 86 0 25 52785841 Fax 86 0 25 52785485 Qingdao Room 1012 Zhuoyue Tower No 16 Fengcheng Road Shibei District Qingdao 26000 P R China Tel 86 0 532 80969935 Fax 86 0 532 80919938 Beijing Room 816 Tower B China Electronics Plaza 3 D...