background image

11/93

Page 1 of 13

INSTALLING AND OPERATING

YOUR MONTIGO 36DV-TV

GAS-BURNING FIREPLACE

Please leave this manual with the owner

CHECK LOCAL CODES PRIOR TO INSTALLATION

FOR YOUR SAFETY

FOR YOUR SAFETY:

IF  YOU SMELL GAS:

1. OPEN WINDOWS.

DO NOT STORE OR USE ANY FLAMMABLE

2. DON'T TOUCH ELECTRICAL SWITCHES.

VAPOURS OR LIQUIDS NEAR THIS OR ANY

3. EXTINGUISH ANY OPEN FLAME.

OTHER GAS-BURNING APPLIANCE.

4. IMMEDIATELY CALL YOUR GAS SUPPLIER.

READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING

MODEL

MONTIGO 36DV-TV

CANADIAN HEATING PRODUCTS INC.

12091 88th Avenue, Surrey, B.C. Canada;  Phone: (604) 597-3115  Fax: (604) 597-3096

Summary of Contents for ECONO-PLUS 36DV-TV

Page 1: ...R YOUR SAFETY IF YOU SMELL GAS 1 OPENWINDOWS DONOTSTOREORUSEANYFLAMMABLE 2 DON TTOUCHELECTRICALSWITCHES VAPOURSORLIQUIDSNEARTHISORANY 3 EXTINGUISHANYOPENFLAME OTHERGAS BURNINGAPPLIANCE 4 IMMEDIATELYCALLYOURGASSUPPLIER READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING MODEL MONTIGO36DV TV CANADIAN HEATING PRODUCTS INC 12091 88th Avenue Surrey B C Canada Phone 604 597 3115 Fax 604 597 3096 ...

Page 2: ... SEEFIGURE2FORFRAMINGDIMENSIONS FIGURE 1 FIREPLACE DIMENSIONS CAUTION The gas line must be installed before finishing the Montigo 36DV TV Fireplace Natural Gas requires an inlet pressure of 7 W C a manifold pressure of 3 5 W C Propane Gas requires an inlet pressure of 11 W C a manifold pressure of 10 5 W C It is also required that provisions be made for a 1 8 N P T plugged tapping and be accessabl...

Page 3: ...mbustible materials Note It is imperative for satisfactory operation of the Montigo 36DV TV fireplace that no venting component be modified in any way All components have been manufactured to eliminate the need for modification when properly selected and installed CAUTIONS AND REQUIREMENTS DIRECT VENT TERMINATION LOCATION This section is used to determine where your direct vent termination will be...

Page 4: ...ngth Maximum retracted length FIGURE 5 TYPICAL INSTALLATIONS Header 10 ft from center of elbow 12 1 2 ft from center of fireplace Stucco Can Vent Termination 3 ft flex section B Solid section includes 90 degree elbow Hearth Wall Thickness 4 12 A FIGURE 6 EXTENDED 10 SECTION 7 1 2 ft from center of fireplace 3 ft flex section 10 ft from center of elbow A B Stucco Can Vent Termination Solid section ...

Page 5: ... Plate Ring E 7 Firestop FS 7 7 Firestop F Roof Flashing MRF 16 1 12 to 6 12 pitch MRF 12 6 12 to 12 12 pitch VERTICAL DIRECT VENT TERMINALS Shall not be installed Less than two feet above the highest point where vent passes through the roof Less than six feet from a mechanical air inlet Less than three feet from a parapet wall Offsets A maximum of two offsets with 90 degree bends may be made and ...

Page 6: ...nlets A B C Horizontal Vertical VENTING GRAPH VENTING GRAPH Venting graph is used for top vent direct vent model only How to use the venting graph 1 Determine the height for the centre of the 7 vent elbow and mark a horizontal line until it intersects with the slanted graph line 2 From the point of this intersection draw a vertical line to the bottom line of the graph 3 Select the indicated dimens...

Page 7: ...combustion door NOTE National Canadian Gas Association mantel test require ments are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temperature...

Page 8: ...lar shaped extension into the log rest located on rear wall of the burner assembly Place the slot of log B over the pilot runner bar located on the left hand front side of the burner assembly Next place logs C and D onto mating positions of logs A and B as shown below FAILURETOINSTALLLOGSASINSTRUCTEDMAY RESULTINEXCESSIVESOOTING FIGURE 13 SAFETY LOCK Knotch Door Turn Turn FIGURE 12 INNER GLASS DOOR...

Page 9: ...ust be cleaned periodically Film can easily be removed by removing inner and outer doors handling carefully and cleaning with normal liquid household products WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etching may cause premature glass failure Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a wh...

Page 10: ...se The decorative gas appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the decorative gas appliance will produce excessive temperatures and will result in a fire hazard LIMITATIONS ON LIABILITY It is expressly agreed and understood that Canadian Heating Products Inc s sole obligation and purchaser s exclusi...

Reviews: