background image

Balance C- and E-types 

InstallatIon and operatIng  

InstructIons 

10/2015

Summary of Contents for Balance C

Page 1: ...Balance C and E types Installation and Operating Instructions 10 2015 ...

Page 2: ...Water thrown on heater 8 Sauna room structure 8 7 Wiring diagram C Type fixed control 9 8 Wall module installation 9 9 The operation of the clock timer and thermostat of the C type 10 Additonal connection options 10 10 Installation instructions E type 11 Installation of the external control and sensor 12 11 Wiring diagram E type 13 Connecting the controller card in the heater 13 Connecting the con...

Page 3: ...e for use in a family sauna one 1 heater sauna room Keep the installation and operating instructions for further reference Always check the adequacy of fire protection distances Failure to observe the wiring instructions may result in a fire risk Always check the sauna room before turning the heater on Always check that the controller has switched off the poser after the set time period Due to the...

Page 4: ... module that is placed on the wall See picture on page 9 4 The package includes the heater E type also an external control unit and its user manual Heater stones are not included 5 The sauna s floor surface should be properly protected before beginning of the installation 6 The electrician connects the wires before the heater is installed to its place During the heater s installation observe the s...

Page 5: ... should be placed not too close to each other this to ensure good ventilation By doing so the sauna heating time will also get shorter than otherwise Continue the stacking of the stones in this way until all stones have been placed Note The resistor may not touch the heater s metal structure anywhere there always needs to be a stone in between Do not stack stones above in the picture below marked ...

Page 6: ...necting cable 5 x 1 5 mm 5 x 2 5 mm Fuse 3 x 10 A 3 x 16 A Model A B C D E Volume Balance 6 6 200 100 850 100 1900 6 9 m Balance 9 0 200 120 870 100 1900 8 13 m Model Stone amount kg Balance 6 6 40 Balance 9 0 40 Table 4 3 Heater dimensions mm Table 4 1 Model Width Depth Height Balance 6 6 412 2 290 9 622 5 Balance 9 0 412 2 290 9 622 5 Table 4 2 Table 4 4 Minimum distances to inflammable material...

Page 7: ...oom is properly venti lated NOTE See also the first time use of type E on p 14 Sauna room Always check the sauna room before turning the heater on Always make sure that the timer has switched off the power after the set time period Temperature control The desired temperature can be set either by a mechanical thermostat see page 10 types C or through the control panel see page 14 E types The actual...

Page 8: ...for every uninsulated square meter the same amount as if increasing space by 1 2 m3 and on timber surfaces by 1 5 m3 Also the glass surfaces glass walls doors and uninsulated stone surfaces are calculated as 1 2 m3 per square meter Choose a higher powered heater in borderline cases The sauna needs to have an efficient ventilation in order to achieve a good oxygen level and get fresh air The air ch...

Page 9: ...ater on 7 Wiring diagram C type fixed control The recommended minimum safety distances between the heater and any inflammable material besides and below the heater are as described in picture 4 4 Floor 8 Wall module installation Targeted height for the upper egde of the heater ...

Page 10: ...e heater will start to warm up after two hours When power has been turned on the heater will remain on for up to 4 hours After this power will be turned off automatically If desired power can be switched off earlier by turning the time switch to zero 0 Always make sure that the time switch has turned power off after the set time period 9 The operation of the clock timer and thermostat of the C typ...

Page 11: ...Installation and Operating Instructions Balance 11 9 Installation instructions E type Supply cable 5 x 1 5 mm2 5 x 2 5 mm2 Sensor RK Controller S PH KHH ca 250 mm ca 250 mm max 990 mm Controller ...

Page 12: ...excess wire and connect the other end to the heater The wall mounting plate is either mounted with three screws to the wall or fixed to the bottom of the mounting box The mount ing plate is covered with a cover plate and finally with the control panel The mounting cable is 8 m Cut the extra cable and connect the other end to the heater When installing the control panel make sure that the cables ar...

Page 13: ... E type Prepared quick connector Connecting the controller card in the heater Connecting the controller card in the controller To the controller To the overheating protection To the thermal sensor White Grey Green Blue Red White White Black Black OVERHEATING PROTECTION ...

Page 14: ...temperature control 2 leds from below Push the quick start button 2h Put the heater on from the left upper corner power switch When 2 hours have passed or the blue led at the down right hand corner has turned off the heater The heater is operated by adjusting its operating time and temperature and then by switching the heater on from the power switch Temperature limiter The temperature limiter res...

Page 15: ...arranty of two 2 years from date of purchase The warranty is limited to 1 year if these products are in commercial use Keep the sales receipt or warranty card The warranty does not cover external or internal mechanical damage caused by for example impacts with a stone or the heater falling over Nor does the warranty cover defects caused by nature like lighting or damages caused by overvoltage Main...

Page 16: ...ce history We recommend replacing the heater stones every 1 2 years Mondex Oy Rantakatu 14 A 67100 Kokkola Finland tel 358 6 8244 333 fax 358 6 8322 355 info mondex fi www mondex fi Date Action The heater s manufacturer ...