background image

U-WAVE-R 

 
 

Introduction 

The U-WAVE-R in conjunction with a Mitutoyo U-WAVE-T (available separately) allows 
wireless communication of the measurement data from Digimatic-output interfaced tool to load 
it to a personal computer for data display.

 

To obtain the highest performance and the longest service life from the U-WAVE-R, carefully 
read this User’s Manual thoroughly prior to use. 
After reading this manual, keep it near the U-WAVE-R for quick reference. 
The specifications of the U-WAVE-R and descriptions in this manual are subject to change 
without prior notification. 

 

Safety Precautions 

Use the U-WAVE-R in conformance with the specifications, functions and precautions for use 
given in this manual. If the U-WAVE-R is used in other way, it may jeopardize safety. 
 

•  Do not use the U-WAVE-R near a medical device that has a possibility of causing a 

malfunction due to radio waves. 

•  The U-WAVE-R using an electric wave has a possibility that communication is 

interrupted under the influence of external noises, etc., even within the distance of 
communication of the electric wave. In this case take sufficient failure prevention 
action (security measures). 

•  In the event the U-WAVE-R should fail, take sufficient failure prevention action 

(security measures). 

 

Notes on Export Regulation 

 

The U-WAVE-R falls into the Catch-All-Controlled Goods or Program under the 
Category 16 of the Separate Table 1 of the Export Trade Control Order or the 
Category 16 of the Separate Table of the Foreign Exchange Control Order,   
based on the Foreign Exchange and Foreign Trade Law of Japan. 
Further, this User's Manual and U-WAVE Quick Manual (No. 99MAL110B)

 

also   

falls into the Catch-All-Controlled Technology for use of the Catch-All-Controlled   
Goods or Program, under the Category 16 of the Separate Table of the Foreign   
Exchange Control Order. 
If you intend re-exporting or re-providing the product or technology to any party   
other than yourself, please consult with Mitutoyo prior to such re-exporting   
or re-providing. 

 

Precautions for the Wireless Law 

The U-WAVE-R can use in Japan, EU member countries, U.S.A, Canada . 
The U-WAVE-R cannot be used in countries other than Japan, EU member countries, U.S.A, 
Canada 

 

• The U-WAVE-R must follow the corresponding regulation which is specified in the   
  country to use an electric wave. 
• Do not disassemble or modify any part of the U-WAVE-R. 
• Do not peel off the following certification label stuck on the U-WAVE-R. 

The use of any U-WAVE-R without the label is prohibited. 

• Do not use the U-WAVE-R in an airplane. 

 

The use of a wireless equipment in the airplane is prohibited. 

 

Changes or modifications not expressly approved by the party responsible 

    for compliance could void the user

’s authority to operate the equipment. 

Notes 

This equipment has been tested and found to comply with the limits for a Class B   
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications, However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of   
the following measures: 
  -- Reorient or relocate the receiving antenna. 
  -- Increase the separation between the equipment and receiver. 
  -- Connect the equipment into an outlet on a circuit different from that to which the 
      receiver is connected. 
  -- Consult the dealer or an experienced radio/TV technician for help. 

 

Precautions on Wireless Communication Environments 

Notice that this performance of the U-WAVE-R may not be fully delivered depending on the 
environment such as a midway obstruction. 
For the items of obstruction factors refer to the following table. 

1) The U-WAVE-R may not be able to communicate in the case. 

Item 

Description 

Concrete wall 

Disables communication if the U-WAVE-R is completely 
enclosed with a concrete wall. 

Metallic partition, etc. 

Have the possibility of reducing the communication speed 
or blocking communication. 

Wireless LAN, Bluetooth, 
ZigBee, microwave oven, 
and other communication 
devices 

Have the possibility of reducing the communication speed 
or blocking communication. Separate the communication 
channel (band ID) and installation site of each device as far 
as possible from those of the U-WAVE-R. 

Machine tools, etc.

 

In the worksite operated with machine tools such as electrical 

discharge Machines, crane for transfer, arc welding etc., 

ave the possibility of reducing the communication speed 

or blocking communication. 

2) 

The U-WAVE-R may influence on the peripheral equipment in the case 

Item 

Description 

Medical device 

Do not use the U-WAVE-R near a medical device such as a 
laser surgical knife and a bathroom scale. 

 

 
 
 
 

 
Precautions for Use 

The following deeds and situations will cause a failure or malfunction in the U-WAVE-R.   
Care should be exercised. 

 

IMPORTANT 

•  The U-WAVE-R operates on the power supply from a personal computer. A personal 

computer may generate large noises depending on the manufacturer and model. Be sure to 
verify the whole system operation once prior to use. 

•  Do not give a sudden shock such as a drop or apply an excessive force to the U-WAVE-R. 
•  If the U-WAVE-R is not used more than 3 months, disconnect the U-WAVE-R from the 

personal computer and store it in a safe place. 

•  Avoid using or storing the U-WAVE-R at sites which are exposed to direct sunlight, 

excessively high or low temperature. 

•  Avoid using or storing the U-WAVE-R at sites where it may be subject to the adhesion of 

solution such as acid and alkali or organic solvent. 

•  If a high-voltage device such as an electro-spark engraving pen is used for the U-WAVE-R, 

the internal electronic parts may be damaged. 

•  Exercise care so as not to apply an undue force or curvature to the USB cable. 

 

Warranty 

In the event that the U-WAVE-R should prove defective in workmanship or material, within 
one year from the date of original purchase for use, it will be repaired or replaced, at our     

option, free of charge upon its prepaid return to us. 

This warranty is effective only where the U-WAVE-R is properly installed and operated in 
conformance with the instructions in this manual. 

 

Electromagnetic Compatibility (EMC) 

The U-WAVE-T complies with the EMC Directive. Note that in environments where 
electromagnetic interference exceeds EMC requirements defined in this directive, appropriate 
countermeasures are required to assure the product performance. 

 

Disposal of Old Electrical & Electronic Equipment (Applicable in the European 
Union and other European countries with separate collection systems) 

 

This symbol on the U-WAVE-R or on its packaging indicates that the U-WAVE-R shall   
not be treated as household waste. To reduce the environmental impact of WEEE   
(Waste Electrical and Electronic Equipment) and minimize the volume of WEEE   
entering landfills, please reuse and recycle. 
For further information, please contact your local dealer or distributors. 

 

[1] Name of Each Part and External Dimensions

 

(Unit : mm)

 

1. POWER (Green LED) 

2. ERROR (Red LED)    3. USB connector   

4. INIT. Switch (Initialize switch) 

5. Device ID label 

  6. Certification label 

 
 
 
 
 

   
   
   
   
   
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  [2] Software Installation

 

 

 

The U-WAVE-R outputs measurement data to a personal computer using the dedicated 

 

 

software “U-WAVEPAK” included in the CD supplied as a standard accessory.

 

 

 

Before using the U-WAVE-R be sure to read the standard accessory   

“U-WAVE QUICK Manual” thoroughly, and then install the “U-WAVEPAK” and “USB Driver”.

 

IMPORTANT 

•  Log in to Windows by ‘Administrator’. 
•  Be sure to install the U-WAVEPAK before connecting the U-WAVE-R to a personal computer. 
•  When connecting the U-WAVE-R to a USB Hub, always use a self-powered USB Hub. 
•  The U-WAVE-R does not support the operation in the Standby or Hibernate of a personal 

computer. Cancel each setting in the U-WAVE-R prior to use. 

•  Please read the “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of the CD supplied as a 

standard accessory for a detailed operation method of U-WAVEPAK. 

       

“Adobe Reader” of Adobe Systems INC. is necessary to read. 

 

[3] Setup

 

 

1)

 

Setting the communication information

 

You need to set various information necessary for communication in the U-WAVE-R using   
the U-WAVEPAK.

 

(No information is registered default setting.) 

The information required to be set is as shown in the following table. 

Item name 

Description 

Group ID 

ID for grouping the U-WAVE-T and the U-WAVE-R. 
Communication is possible between the U-WAVE-T and the U-WAVE-R 
which have the same ID. 

Band ID 

Number of a radio band to be used 

Lack of data 
monitoring 
level 

The data transmitted from the U-WAVE-T to the U-WAVE-R includes a value 
that is incremented by one each time communication is implemented.   
The U-WAVE-R monitors this value and has a function to notify the personal 
computer of a data missing error. 
A lack of data monitoring level is a value for prescribing how frequently this 
error is notified. 

 

IMPORTANT 

•  Please read the “U-WAVE Quick manual “ and “U-WAVEPAK User’s Manual“ in “PDF_Manual” 

  folder of the CD supplied as a standard accessory for setting the communication information. 

• The U-WAVE-R will not function properly if a U-WAVE-R with the same group ID and band 

ID settings exists nearby. Be sure to set different information for each ID in the U-WAVE-R. 

 

 

5. Device ID label 

6. Certification label 

 

3. USB connector 

4. INIT. switch 

1. POWER 

(Green LED)

 

2. ERROR 

  (Red LED) 

WARNING 

! 

WARNING 

! 

WARNING 

! 

User

’s  Manual 

No.99MAL109B6 

 