background image

 
 
 

 

INDUSTRIAL SEWING MACHINE   
CC-Link IE FIELD BASIC Communication Equipment 

 

MODEL 

PLK-J-LAN

 

 

TECHNICAL MANUAL

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

A180E805P01 

Summary of Contents for PLK-J-LAN

Page 1: ... INDUSTRIAL SEWING MACHINE CC Link IE FIELD BASIC Communication Equipment MODEL PLK J LAN TECHNICAL MANUAL A180E805P01 ...

Page 2: ...__________________5 6 External dimensions ___________________________________________7 7 Connection method ____________________________________________7 1 How to XC G 8 2 How to PLK G 8 8 Installation and setting__________________________________________9 9 How to use ___________________________________________________10 10 Confirmation _________________________________________________11 11 Error ...

Page 3: ...ct and long term use The contents of this manual may not be reproduced in part or whole The contents of this manual are subject to change without notice An utmost effort has been made to cover all points of operation in this manual Contact Mitsubishi if you have any questions regarding the contents COPYRIGHT C 2018 MITSUBISHI ELECTRIC CORPORATION ...

Page 4: ...corrosive gases etc In a flammable gas or explosive environment 5 Vibration Where the Excessive vibration 2G or more or many shocks Installation Please install it correctly according to this manual Cable Lay the connection cables so that excessive force will not be applied during operation Do not excessively bend the cables Remove 1 Always turn the power switch OFF of the sewing machine and discon...

Page 5: ...fluence of high frequency noise attach the ferrite core to the RS232C cable of PLK J LAN 7 Notes on turning on the power again Please make sure not to turn on the power supply switch until after the LED on the front panel of the control box has completely turned off Please note that if power supply is turned on again while LED still turns on the data in the PLK J LAN may be damaged 8 If you need t...

Page 6: ...th the master station as slave station Required network equipment Equipment of the master station Mitsubishi Electric PLC MELSEC iQ F iQ R series Equipment for display PC Mitsubishi Electric Display etc Other equipment HUB etc 2 Simplified drawing CC Link communication connection Compatible models Mitsubishi RIMI Servo XC G series Electronic pattern stitch sewing machine PLK G series Electronic pa...

Page 7: ...ion port for I O function 7 CON D USB A connector USB flash drive and barcode reader can used 8 CON E LAN connector Connect the LAN cable USB A connector of this product Applicable condition USB flash drive USB1 1 or USB2 0 or USB3 0 compatible USB flash drive Barcode reader HID type Inapplicable devices USB device requiring an external power supply including Computer devices USB hard disk drive k...

Page 8: ...onnector pin ratings current ratings voltage O1 CON C 4PIN 100mA less DC 24V less O2 CON C 5PIN 100mA less DC 24V less Example of use 2 Input Example of use Inside the PLK J LAN External power supply load Used connector TE Connectivity 172161 1 Used terminal TE Connectivity 170362 1 Please use external power supply as the power source of the connected equipment I1 I2 GND Please use GND of PLK J LA...

Page 9: ...connection destination at 1kΩ or more Example of use 4 Analog input input Connector pin power Output voltage AN0 CON C 7PIN DC12V DC 0 12V AN1 CON C 8PIN DC12V DC 0 12V Example of use PLK J LAN Power Input 0 10V 1 GND 1 Input resistance 1kΩ or more Output total 0 1A or less PLK J LAN External volume resistor 10kΩ Input devise DC12V DA0 GND DC12V AN0 AN1 GND ...

Page 10: ...ternal dimensions 7 Connection method Back side Front side Operation box XC G10 XC G500 XC G control box PLK G control box PC PLC HUB Network equipment CON B CON E RS232C cable 4 5 125 3 155 3 139 40 125 φ4 5 ...

Page 11: ...ox Cable XC G10 XC G500 Operation box XC G Control box PC PLC HUB LAN cable LAN cable RS232C cable PLK J LAN Back side PLK J LAN 前面 PLK G Control box PC PLK J LAN back side Connect the RS233C cable of PLK J LAN to the front panel of the control box PLC LAN cable LAN cable HUB PLK J LAN front side ...

Page 12: ... by dedicated PC application IPEdit For dedicated PC applications please contact the dealer USB flash devise configuration Folder name Required data USB flash devise PLKJ_SYSTEM APP_DATA LAN system data MAKER IP PLK setting data IP address subnet mask default gateway For necessary settings such as PLC refer to the owner s manual of the used equipment 1 Installation and setup method Connect USB to ...

Page 13: ...ke necessary settings such as PLC Please refer to the instruction manual of other equipment you use PLK G Initial setting 1 Connect the wiring before turning on the power Connect the RS232C cable of PLK J LAN to the MINI DIN connector on the PLK G front panel Connect the network equipment to the CON E on the back of the PLK J LAN with a LAN cable 2 Please prepare the LAN system data etc in the USB...

Page 14: ...2 After turning switch on 1 Is the front panel power LED green on 2 Is the front panel warning LED red on or flickering 3 Is there an heating odors or abnormal noise from the motor or control box When you turn on the power a click noise comes from inside the control box This noises are not abnormal Turn the sewing machine off and contact your dealer if there is any heating odors or abnormal noise ...

Page 15: ...1 Check the LAN cable connection Please exchange the LAN cable Please reinstall LAN system data Ethernet initialization error Blink pattern 2 Please reinstall LAN system data Installation error Blink pattern 4 Please check the installation file and reinstall RS232C communication error Blink pattern 5 Check the RS232C cable connection Please reinstall LAN system data USB over current Blink pattern ...

Page 16: ...n 1 port RS232C serial communication 2 port USB communication 2 port External storage medium USB flash drive External input output CON C Input 4 point analog 2 point Output 3 point analog 1 point total 7 point External dimensions 125mm W 155mm W 40mm H mass 300g Ethernet communication Communication standard 10BASE T 100BASE TX interface RJ 45 connector 1 port Communication speed 100Mbps Supported ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...MITSUBISHI ELECTRIC CORPORATION Printed in Japan ...

Reviews: