background image

 

Page 1

INTRODUCTION 

The 

ALERT 

(

A

TTENTIVE 

L

IVING 

THROUGH 

E

NERGIZING 

R

EGENERATIVE 

T

ECHNOLOGY

)  integrates  the  necessary  principles  of 

audio/visual  stimulation  to  safely  and  effectively  guide  the  user  into 

desired  states  relaxation  and  attention,  ideal  for  those  with 

ADD/ADHD and/or cognitive decline.    

 

The ALERT is non-invasive.  All resulting effects are produced in the 

brain  solely  by  audio-visual  stimuli.  The  portability  of  the  ALERT 

lends  itself  to  easy  travel  (airport  X-ray  machines  will  not  harm  the 

ALERT). 

 

In  order  to  obtain  maximum  enjoyment  and  benefits  from  your 

ALERT, please read this operator's manual thoroughly.

 

 

COMPONENT LIST 

(1)  ALERT - Serial Number __________________ 

(2)  Tru-Vu Omniscreen

TM

 Eyeset (U.S. Patent 5,709,645)

(3)  Headphones 

(4)  Stereo Patch Cord 

(5)   Carry Bag 

(6)  9-Volt Alkaline Battery 

(7)  ALERT Operator's Manual 

(8)  Warranty Card 

 

OPTIONAL ACCESSORIES FOR ALERT 

 

(1)  9-Volt Adapter 

(2)  DAVID Session Editor 

(3)  Two-User Package (includes: eyeset, headphones, splitter cords) 

(4)  Tru-Vu Omniscreen Viewhole Eyeset 

 

If  you  have  any  questions,  require  assistance,  or  wish  to  receive 

information on new product developments and research currently 

being  conducted  at  Mind  Alive  Inc.,  visit  our  website  at 

www.mindalive.com

  or  call  toll  free  at  1-800-661-MIND(6463).  

Outside Canada and the U.S. call (780)465-6463.  

 

Summary of Contents for DAVID ALERT

Page 1: ...d benefits from your ALERT please read this operator s manual thoroughly COMPONENT LIST 1 ALERT Serial Number __________________ 2 Tru Vu OmniscreenTM Eyeset U S Patent 5 709 645 3 Headphones 4 Stereo Patch Cord 5 Carry Bag 6 9 Volt Alkaline Battery 7 ALERT Operator s Manual 8 Warranty Card OPTIONAL ACCESSORIES FOR ALERT 1 9 Volt Adapter 2 DAVID Session Editor 3 Two User Package includes eyeset he...

Page 2: ...commend that you drink a glass of water prior to your session If at any time during a session you begin to feel vertigo nausea euphoria or a sense of mental instability lower the intensity of the eyesets and lower the volume of the tones or discontinue the session It is the responsibility of the health care provider to complete a proper intake addressing the concerns mentioned above Mind Alive Inc...

Page 3: ...an normal use improper battery installation and or charging cords for headphones and OmniscreenTM eyeset damage caused by exposure to excessive static electricity damage caused by any unauthorized person tampering with the ALERT Should your ALERT require repairs you must contact our service department at 1 800 661 MIND Canada and U S only or 780 465 6463 to obtain a warranty repair authorization n...

Page 4: ...emand action cause of action liability or damages arising out of any injuries resulting from malfunction or defect of the said ALERT whether wilful or negligent either to person or damage to property of the purchaser employees of the purchaser persons designated by the purchaser for training in the use of the ALERT clients or patients of the purchaser any other person designated by the purchaser f...

Page 5: ...that the ALERT is on or in standby 4 9 Volt Adapter Jack Insert adapter plug into adapter jack use a 9 volt adapter with 1 3 mm plug and centre positive 5 Session Number Lights 1 6 Indicates the session number They are also used to display the battery power intensity and volume levels 6 A B C Indicator Lights Indicates the session bank 7 VOL Button Volume Note button raised to guide you in locatin...

Page 6: ...r off 10 OMNISCREEN Jack Insert Omniscreen eyeset plug into OMNISCREEN jack Use the patch cord with the small 2 5 mm plug 11 HEADPHONE Jack Insert headphone plug into HEADPHONE jack 12 AUDIO IN Jack Use to listen to music during a session Also use to download or erase a session with the DAVID Session Editor Plug one end of the patch cord with the larger 3 5 mm plug into the headphone output of you...

Page 7: ...s the ALERT is turned on the battery power level will show on the lights from 1 to 6 If the power level is 1 then the battery is too low to operate the ALERT and it will automatically go into standby If the power level is 2 the battery may not have enough power for the entire session If the battery power gets too low during a session the session will end early with Soft Off The number indicator li...

Page 8: ...rtbeat off press and hold the SEL button for approximately one second To turn the heartbeat back on press and hold the SEL button again for approximately one second Selecting Pulsed Tone Binaural Beats Chime All of the ALERT sessions except session C6 begin with the Classic tone on Press the SEL button once to select Binaural Beats Press the SEL button again to select Chime Press SEL once more to ...

Page 9: ...ace the battery slide battery compartment cover off Ensure that the battery is lined up properly for positive and negative posts Refer to Figure 2 page 6 Slide the bottom of the battery into the battery compartment under the edge push the battery down into place to connect the poles If the ALERT is plugged into an adapter no power will be used from the battery The ALERT will remain in standby at t...

Page 10: ...loth slightly moistened with water or with a mild detergent Do not clean with any solvents Although precautions have been taken to protect the ALERT from static electricity do not subject the ALERT to static such as placing it near a television set or static producing fabrics and materials Do not place the ALERT near heat sources such as radiators or air ducts or in direct sunlight or expose to ex...

Page 11: ...heta Alpha IV 22 min Group 2 Sessions A5 Sensory Motor Rhythm I 22 min A6 Sensory Motor Rhythm II 22 min B1 Sensory Motor Rhythm III 22 min Group 3 Sessions B2 Beta I 22 min B3 Beta II 22 min Group 4 Sessions B4 Instability I 22 min B5 Instability II 22 min Additional Sessions C1 Schumann Resonance 40 min C2 Sensory Motor Rhythm Use with Viewhole Eyeset 20 min while reading C3 Attention Used in Jo...

Page 12: ...t plugged Check eyeset connection on left side only in completely Tones in headphone are Headphone not Check headphone on left side only sound hollow plugged in completely connection No sound from audio Plugged into audio Check all connections player player incorrectly to audio player Download is not recognized Audio player improperly Check all connections plugged in to audio player Volume too hig...

Page 13: ...oncerns mentioned above Mind Alive Inc its employees suppliers and distributors are exempt of any liability in damages resulting from a seizure or psychiatric condition that may occur from prescribing this device THE ALERT IS NOT RECOGNIZED AS A TREATMENT OR CURE OF ANY MEDICAL CONDITION OR DISABILITY HOWEVER RESEARCH SUGGESTS THAT THE ALERT IS AN EFFECTIVE RELAXATION AND MEDITATION TOOL The ALERT...

Page 14: ...omponent List 1 Optional Accessories 1 Warning 2 Precautions 2 Warranty 3 Disclaimer of Liability 4 ALERT Diagram 5 Operating Instructions 7 Care and Maintenance for the ALERT 10 Description of Preset Sessions 11 Before You Call for Repairs 12 ...

Page 15: ...Page 15 ALERT ...