background image

Operating and Installation manual
Vented Dryer
PT 5136

To prevent accidents
and machine damage
read these instructions

before

installation or use.

M.-Nr. 09 758 410

en - US, CA

Summary of Contents for PT 5136 OS

Page 1: ...Operating and Installation manual Vented Dryer PT 5136 To prevent accidents and machine damage read these instructions before installation or use M Nr 09 758 410 en US CA ...

Page 2: ...eaning the lint filter 19 Cleaning the grid filter 20 Cleaning the exterior and the control panel 20 Frequently asked questions 21 After sales service 27 Optional accessories 27 Installation instructions 29 Installation 30 Electrical connection 35 Installation of exhaust venting 36 General notes 36 How to calculate the effective duct length 37 Determining the position of the exhaust connection 40 ...

Page 3: ...ins electrical supply If in doubt contact an electrician The electrical safety of this appliance can only be guaranteed when continuity exists between the machine and an effective grounding system which complies with local and national regulations It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified technici...

Page 4: ...ermeability Lint can collect and block the air flow If an exhaust hose is already installed it should be checked before connected to the dryer Danger of suffocation or toxication Adequate ventilation is essential especially when another appliance which also uses the room air e g gas oil or coal fired heater continuous flow or other water heater is installed in the same or an adjacent room Allow su...

Page 5: ...ish remover etc When washing heavily soiled items ensure that sufficient detergent is used with a high temperature If in doubt wash the item several times items containing foam rubber or similarly textured rubber like materials items with padding or filling e g pillows or jackets which have been damaged Loose filling could catch fire Do not lean on the door The dryer may tip over Always close the ...

Page 6: ...ge for more information d m Delay Start button Time of day display eOptical Interface PC Allows a service technician to check and update the drying programs f Low temperature button gProgram selector To select a wash program The program selector can be turned clockwise or counterclockwise hDoor button To open the drum door Guide to the dryer 6 ...

Page 7: ...n during drying to get the approximate program end time or the current time of day Remaining time When a program is selected the approximate duration is displayed This is the remaining time The program duration can vary due to some factors Residual moisture after spinning fabric load size room temperature or voltage fluctuations The adaptive electronic adjusts to the individual load to display the...

Page 8: ...ired language with the buttons and confirm with OK The selected language is marked with a check Setting time of day 10 00 Set the time of day Set the time of day with the buttons the hours and confirm with OK Set the minutes and confirm Basic menu The basic menus with the current time of day shows as long as no program is selected The display shows Settings J 10 00 Please select Settings F The inf...

Page 9: ...olored items before drying for the first time and do not dry with light colored items These fabrics can bleed also on plastic parts of the dryer Colored fluff may also get on the light colored items Wool and wool blends tend to felt and shrink Dry wool and wool blends in the Woollen handcare program The fine fabric of down filled items tend to shrink Dry these items in the Smoothing program Dry pu...

Page 10: ...t small items from getting trapped inside of them Close zippers hooks and eyelets Tie fabric belts and apron ties Remove or sew released bra underwires 2 Load the laundry Use the Door button to open the drum door Load the laundry loosely into the drum Do not overload the drum Overloading strains the fabrics and results in poor drying results To prevent fabric damage check that laundry is not caugh...

Page 11: ... name is shown Cottons Important The displayed duration varies with every program selection Cottons Minimum iron Normal Duration 1 16 h Different drying levels can be selected Towelling Woollen handcare Smoothing The drying level and duration are fixed Cool Warm air 1 00 h Warm air Duration 1 00 h The duration can be extended or shortened with the button up to 2 hours cold air 1 hour warm air Use ...

Page 12: ...e the drying level except Proofing Low temperature To dry delicate items fabric care symbol r e g made from acrylic press the Low temperature button The temperature is reduced and the program duration is extended 4 Select Delay Start if desired See Delay Start 5 Insert coins if operated by coin mechanism If a coin mechanism operates the machine please regard the displayed request to pay If the doo...

Page 13: ...ogram is finished These programs do not have a cooling down phase Woollen handcare Smoothing 7 At the end of a program Anti crease if selected and End mark the end of a program in the display During the anti crease phase the drum will turn in intervals if the laundry is not immediately removed from the dryer This will prevent the laundry from wrinkling Run time 1 h Use the Door button to open the ...

Page 14: ...l program To select a different program the running program must be canceled Canceling a program Turn the program selector to Finish If Finish shows in the display the program was canceled Open and close the door Select the new program Press the Start button Adding removing laundry during a drying program Press the Door button Open the door Do not touch the rear of the drum while adding or removin...

Page 15: ...aundry etc Note Select Low temperature for items with the fabric care symbol r Roll up items until they are machine ironed to keep them moist Minimum iron Load size 7 7 lbs 3 5 kg Normal Normal Hand iron r Items Minimum Iron items of cotton mixed fabrics or synthetics e g sweaters dresses pants table cloths etc Note Select Low temperature for items with the fabric care symbol r Select Hand iron r ...

Page 16: ... which time is most suitable Woollen handcare Load size 5 5 lbs 2 5 kg Items Woolen fabrics Note Woolen items will be loosened up and fluffed in a short time but not completely dried Remove the items immediately after the program end and allow to air dry Low temperature cannot be deselected Smoothing Load size 6 6 lbs 3 kg Items Cotton or linen fabrics Minimum iron items of cotton mixed fabrics or...

Page 17: ... kg Normal Hand iron r Items Outdoor clothing suitable to dry in a tumble dyer Proofing Load size 5 5 lbs 2 5 kg Items For dryer suitable items e g ski and outdoor clothing table cloths and poplin items Note This program has an additional step for the water proofing Water proofed items must only be treated with water repellant that is Suitable for membrane textiles These chemicals are based on flo...

Page 18: ...gly Press the button to select an earlier program end time Confirm with OK Starting the Delay Start Press the Start button Normal Begin in 0 45 h The time elapses in minutes until the program start The drum turns briefly every hour to prevent creases Changing a program As long as the program has not yet started the Low temperature option or drying level can be adjusted Press the Door button to add...

Page 19: ...n the hollow part of the door can be removed through the gap at the bottom with a dust brush or vacuum Clean the door gasket 2 with a damp cloth The lint filter can be rinsed with hot water if clogged or clotted Rinse the filter with hot water Dry the lint filter before putting it back in place Inserting the lint filter Return the cleaned lint filter Close the door Check and clean the lint filter ...

Page 20: ... by turning the knobs until a click is heard Cleaning the exterior and the control panel To reduce the risk of electric shock disconnect this appliance from the power supply by unplugging or tripping the circuit breaker Do not use abrasive cleaners glass cleaners or all purpose cleaners They will damage the dryer Do not hose the dryer down The exterior and the control panel can be cleaned with war...

Page 21: ...lectronic notes that no laundry is in the drum and cancels the program Single items or already dried laundry can also cause a program stop Single items should be dried with a Timed drying program To delete the message Open the door Technical fault A numerical fault message shows e g F47 The fault cannot be detected immediately In some cases Clean out airways is displayed See Clean out airways To d...

Page 22: ... OK The exhaust duct maybe very long This is not a fault With a long exhaust duct program times and energy consumption increase The cycle of the Clean out airways indicator can be adjusted See Menu Settings Supervisor level Cleaning the airways Program change not possible A running program needs to be changed To select a different program the running program must be canceled Progr end time delayed...

Page 23: ...l vent bends etc for air permeability Remove the lint The laundry was not spun sufficiently in the washer Spin laundry thoroughly before drying The dryer is over loaded Regard the maximum load size per program Metallic zippers prevent a correct measurement of the laundry s residual moistness Open the zippers of the laundry before drying If the problem persists dry the items with long zippers only ...

Page 24: ... of synthetic fabrics have static cling after drying Synthetics are prone to static cling Use liquid fabric softener in the last rinse of the wash to minimize the static cling during drying Lint has built up Lint is the result of friction caused by items being worn and washed This lint is loosened during drying It has been established by research institutes that dryers have no detrimental effects ...

Page 25: ...ge The flag symbol leads you to the setting The Start indicator flashes when selecting a program This is not a fault It indicates that the program can be started After the program was started the indicator lights steadily The display is dark the ring light of the program selector does not light The Start indicator flashes slowly The display and the program selector go into Standby to save energy P...

Page 26: ...d twist see illustration Flip down the bulb cover Replace the light bulb with a temperature proof bulb available from Miele The light bulb must not exceed the maximum wattage quoted on the data plate Replace the light bulb with a new one Flip the light bulb cover upwards and press it firmly onto the left and right side until it clicks into place Make sure the bulb cover is securely closed to preve...

Page 27: ...and serial number of your appliance They can be found on the data plate located below the drum opening The PC indicator allows a service technician to check and update the drying programs The update allows future developments of fabrics detergents and drying programs to be incorporated into the machine s electronic control Optional accessories Optional accessories are available from Miele After sa...

Page 28: ...28 ...

Page 29: ...Installation Instructions To prevent accidents and machine damage read these instructions before installation or use ...

Page 30: ...Exhaust connection The exhaust hose can be installed either at the rear left or right of the dryer b Power cord c Control panel d Door e Four height adjustable feet f Cement base gFixing bracket for installing on a concrete plinth ...

Page 31: ...Side view Rear view a Lid over hang with transport grips arrow b Stand Optional accessory Installation 31 ...

Page 32: ...r can be installed as part of a washer dryer stack in combination with a Miele washer An appropriate stacking kit available from Miele is required Installation of the stacking kit must be completed by a Miele Service Technician Installation 32 ...

Page 33: ...e s Technical Service will install the coin mechanism and program the dryer electronic Empty the coin mechanism regularly to avoid the coins getting jammed Do not install devices to automatically turn the dryer off e g clock timers Installation 33 Secure both front feet on the dryer using the fixing brackets supplied ...

Page 34: ...transport the dryer from the packaging base to the installation site Level the dryer The dryer must be level to ensure safe and proper operation The machine can be leveled by turning the legs clockwise or counterclockwise as necessary An air gap of 3 8 10 mm must be provided between the machine and the floor The vents must not be blocked by toe kicks long piled carpet etc This dryer cannot be inst...

Page 35: ...current of 30 mA If the machine is hard wired three 30 A circuit breakers must be provided on site Switches with a contact gap of more than 1 8 3 mm are valid as separators All components have to bear CSA or UL approval The machine must only be connected to the voltage and frequency shown on the data plate To convert the machine to another electrical connection please read the conversion manual on...

Page 36: ... exhaust connection e g a wall pipe must be installed so that the moist exhaust air cannot get drawn back into the installation room and cause constructional damage or unreasonable disturbance Provide sufficient venting in the room where the dryer is installed by opening a window or installing unlockable ventilation openings in the wall Danger of suffocation by suction of exhaust fumes Installatio...

Page 37: ... the necessary duct diameter is not employed Tips about the ductwork Check with your local building code to determine the maximum allowable duct length Use a flexible metal pipe or rigid a metal pipe for venting Non metallic flexible hose should not be used it is a potential fire hazard Use the wall vent or window connection optional accessories for venting outdoors For optimal drying results avoi...

Page 38: ...e 90 angle 10 10 25 25 5 11 4 11 8 2 180 150 250 Smooth metal duct 3 3 1 m straight 45 angle 90 angle 10 10 25 25 3 3 1 11 2 7 100 60 80 Elbow 90 sharp 7 6 230 Concertina bend 90 angle 8 20 2 4 70 Wall vent or window vent with louvers with flap 12 5 4 11 380 150 Exhaust connection left or right side 3 3 100 Installation of exhaust venting 38 ...

Page 39: ... m A Wall duct with louvered wall vent 12 5 3 8 m B 90 bend 2 7 0 8 m C 20 0 5 m rigid pipe 1 7 0 5 m D 90 bend 2 7 0 8 m E left vent opening 3 3 1 0 m Total duct length 22 5 6 9 m The total duct length is less than 33 feet 10 m so a duct diameter of 4 100 mm with adapter is sufficient Installation of exhaust venting 39 ...

Page 40: ...ar of the dryer factory standard or moved to the left or right side of the dryer Changing the position of the exhaust connection Remove the cap turning it counterclockwise Press the supplied cover firmly into the rear opening Install the exhaust duct as follows Installation of exhaust venting 40 ...

Page 41: ...ional accessory an exhaust hose made of approved non flammable material rigid pipe is more suitable for long ducts less friction Install the connector 1 with the exhaust hose or pipe 2 to the dryer Window connection 1 Window connection installed in a plexiglass pane 2 Connector for the flexible exhaust hose Wall connection with rigid pipe 1 Wall pipe 2 Connector 3 Rigid pipe Installation of exhaus...

Page 42: ... wall pipe 2 Connector for the flexible exhaust hose 3 Chimney humidity insulated The appliance must not be connected to a chimney or vent flue which is in use Neither should it be connected to ducting which ventilates rooms with fireplaces Installation of exhaust venting 42 ...

Page 43: ...r will be However for the wall pipe to be installed a hole must be cut through the outer wall Regard the Install manual for the Miele wall pipe and the dimension illustrations below Necessary materials wall pipe optional accessory a flexible spacer ring optional accessory Dryer top view 1 Wall pipe 2 Flexible foam gasket space ring Installation of exhaust venting 43 ...

Page 44: ...Dryer side view 1 Wall pipe 2 Flexible foam gasket space ring Connect the flexible space ring 2 to the wall pipe connector 1 Push the dryer to the wall Installation of exhaust venting 44 ...

Page 45: ...ers can be damaged and the electrical safety compromised When installing multiple dryers increase the duct diameter Number of units Increasing factor for duct diameter from table 2 2 3 4 max 5 1 1 25 1 5 1 Connection to collecting duct 2 Non return flap 3 Additional adapter 4 Vent hose Push the non return flap 2 into the adapter 3 Installation of exhaust venting 45 ...

Page 46: ...al 130 l Maximal load 14 3 lbs 6 5 kg Dry laundry weight Power cord 63 1 600 mm Fuse rating see data plate Rated load see data plate Fuse rating see data plate Light load see data plate Testing approvals Radio TV Suppression VDE in Germany Maximum floor pressure during operation approx 159 lbs 72 kg Noise level according to 3 GSGV 70 dB A Technical Data 46 ...

Page 47: ...tic wrappings bags etc are disposed of safely and kept out of the reach of children Disposal of an appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Ensure that a discarded dryer presents no danger to children While being stored for disposal remove the door to the drying compartment C...

Page 48: ...48 ...

Page 49: ...justed to changing demands through the settings Depending on default settings some settings are visible and can be changed by all users Menu Settings J or all setting are locked in the Supervisor level by a code Menu Settings Supervisor level Contact Miele Technical Service ...

Page 50: ...Select Back and confirm with OK Language J The displayed language can be set in the submenu Language J The flag behind the word Language is a guide to find the settings menu in case a foreign language is selected Anti crease The drum will continue to turn in intervals for one hour after the program has ended if the laundry is not immediately removed Delivery status on Time of day This selection al...

Page 51: ...hen the buzzer is selected a tone sounds at the end of a program Off The end of program buzzer is turned off However it does not turn off the warning tone indicating a fault message normal The buzzer sounds at the end of a program normal factory default loud The buzzer sounds at the end of a program loud Lengthening the cooling time The cooling phase can be lengthened before the program is started...

Page 52: ...with OK Enter the second and third digit Confirm the code with the OK button or correct it pressing Supervisor level Changing the code The access code for the supervisor level can be changed Insert the old code Insert the new code After confirming the new code the basic menu shows Drying levels The bar shows the selected level Factory default middle level The program duration is shortened laundry ...

Page 53: ...evel of lint collection the indicator should come on off Clean out airways does not light up heavy Clean out airways shows only when lots of lint is collected normal Factory default light Clean out airways shows even when little lint is collected Cool air free If the dryer is used with a coin mechanism the program Cool air can be provided for free free factory default Menu Settings Supervisor leve...

Page 54: ...54 ...

Page 55: ...55 ...

Page 56: ...ervice Canada Importer Miele Limited Headquarters and Miele Centre 800 843 7231 609 419 9898 609 419 4298 Technical Service Support Nationwide Phone Fax TechnicalService mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca 800 999 1360 888 586 8056 Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 Germany Manufacturer Miele Cie KG Carl Miele Straße 29 33332 G...