background image

Tel: 

+353 46 95 58030

Fax:

 

+353 46 95 58034

Email:

 

[email protected]

Web:

 

www. miflues.ie

SYSTEM 7

Vitreous Enamelled

Steel Stove Pipes

System7 Single.indd   1

28/06/2013   14:58

September 2014

Summary of Contents for SYSTEM 7

Page 1: ...Tel 353 46 95 58030 Fax 353 46 95 58034 Email sales miflues ie Web www miflues ie SYSTEM 7 Vitreous Enamelled Steel Stove Pipes September2014 ...

Page 2: ...e sealed with Mi Flues high temperature sealant rated to 1000 C or fire cement in accordance with appliance manufacturers guidelines There is a hole in the spigot end of the pipe This hole is used in the manufacturing process and is in no way used for installation purposes If the fit is quite loose it is possible to pack the joint with fire rope prior to using the high temperature sealant rated to...

Page 3: ...s do not recommend cutting vitreous enamel pipes Adjustable lengths are available to assist in achieving the exact length required They are available in 125mm and 150mm diameters Adjustable lengths are available in a matt black gloss black or brown finish The short component is adjustable from 310 480mm The long component is adjustable from 510 880mm Available in 300mm 500mm 1000mm and 1200mm MI F...

Page 4: ...duct Dia A B C Sys 7 100 114 154 Sys 7 125 128 168 Sys 7 150 132 173 Sys 7 175 148 188 Sys 7 200 164 199 90 Bend 45 Insulated Sleeve Product Dia A B C Sys 7 100 150 140 Sys 7 125 180 140 Sys 7 150 200 140 Sys 7 175 225 140 Sys 8 200 250 140 Used to provide a 45 change of direction or can be used in pairs as an offset Two by 45 bends can be used to create a 90 bend Used to provide a 90 change of di...

Page 5: ...sh They can however be sprayed using a suitable enamel paint which is available from your local merchant Product Dia A B C Sys 7 100 125 155 Sys 7 125 150 155 Sys 7 150 175 155 Product Dia A B C Sys 7 100 207 207 Sys 7 125 230 230 Sys 7 150 254 254 Sys 7 175 281 281 Sys 7 200 307 307 45 Rosette Plate 90 Rosette Plate Coloured finish access door Start Off Adaptor This is used to connect an applianc...

Page 6: ...curely fixed in an unobtrusive but obvious position within the building such as next to the electricity or gas consumer unit next to the chimney hearth or next to the water supply stop cock Connection to the Chimney Safety Installation Regulations System 7 must only be used to make the connection between the appliance outlet spigot and the chimney It should not pass through any roof space partitio...

Page 7: ...any other substances which may be harmful System 7 Technical Data Fuel Solid Fuel Oil Gas Material 1 8mm Double sided vitreous enamelled steel Min Distance to combustibles Four times diameter of flue OFFSET CHART The offset chart below is using the recommended Mi Flues System 7 45 bends Within a run of system 7 flue no more than two bends should be used Two bends are used to create one offset PROD...

Page 8: ...rent Building Regulations Mi Flues has adopted a policy of continuous product review and in the interests of development and improvement the Company reserves the right to vary the appearance and performance of any of its products without prior notice Correct at time of print September 2014 For updates please check our website Mi Flues Ltd Summerhill Enterprise Ctr Summerhill County Meath IRELAND T...

Reviews: