background image

FL420 

Electronic Locking

User Guide

Section 1: General Information

Section 2: Unlock & Lock Cart

Section 3: Manually Lock & Unlock Cart

Carts always arrive with 4 pre-programmed codes. If a cart comes with

a keyless controlled substance drawer, there will be 5 pre-programmed

codes at the time of delivery, the 5th being the default code to open the

keyless narcotics drawer. The following is a review of each:

To Unlock the Cart:

To Lock the Cart:

To Unlock a CS Drawer:

- Press any key to wake up touch pad.
- Enter 4-digit User Code and press OK.
- The cart will now be unlocked.

- Press "SIGN OUT" key.

Only for carts that are equipped with a Controlled Substance

drawer. The factory default code is 7777 with 1234 as the PIN. Both

must be changed before narcotics are placed in the drawer. The cart's

main lock must be disengaged to access CS drawers.
- Press any key to wake up touch pad.
- Enter 4-digit User Code & Press OK.
- The second line of the display will read "PRESS CS TO UNLOCK

NARC DRAWER".

- Press the CS key.
- Enter a valid CS code & press OK.
- If an optional PIN has been added to the ID, the display will prompt to

enter the PIN & Press OK.

- The keyless narcotic/storage drawer that is linked to your CS code

will unlock.

Note:

The cart can be unlocked and locked manually (without the touchpad

or electronics) by using the key lock and red lock knob.

To Unlock the Cart:

To Lock the Cart:

To Unlock a CS Drawer:

To Recharge Batteries:

Change Set Up Code:

Change Service Code:

- Insert the key into the mechanical key lock and turn counter

clockwise.

- The front lock handle will spring up signaling the cart is unlocked.

- Press down on the red lock knob until it clicks into place.

- Unlock the main cart lock.
- Insert the key into the mechanical key lock on the front of the CS

drawer. Turn the key, open drawer and remove the key.

- Close the drawer to relock the drawer.

A "LOW BATTERY-RECHARGE" message is displayed on the LCD

screen when it's time to recharge batteries. It is recommended that

batteries be routinely recharged once a week for 6 to 8 hours.

- Plug the recharger into a standard 120VAC wall outlet.
- Plug the recharger jack into the 12" long breakaway extender, and the

angled male end of the extender into the jack on the back of the cart.

- The extender is important. It will help to prevent drive-away damage if

the cart is moved while connected to the recharger.

- While the battery is charging, the light on the recharger will be either

red or yellow; when fully charged it will turn to green.

- Press any key to wake up touch pad.
- Enter Set Up Code & Press OK.
- Press "FUNCTION" key several times until "SET THE CART ID" is

displayed & Press OK.

- Enter New 3-digit Set Up Code & Press OK.
- Enter PIN number to coincide with new Set Up Code or Press OK to

skip.

- Press OK to accept new Set Up Code / PIN number.
- Enter Set Up Name or Press OK to skip.
- Press OK to accept Set Up name.
- Press "SIGN OUT" to exit Set Up Mode.

- Press OK to wake up touch pad.
- Enter Set Up Code & Press OK.
- Press "FUNCTION" key several times until "SET NEW SERVICE ID"

is displayed & Press OK.

- Enter New 3-digit Service Code & Press OK.

The Set Up and Service ID numbers are limited to 3 digits each.

Management and Operator numbers have 4 digits with an optional 1 to

4 digit PIN. CS(controlled substance) codes consist of a 4 digit

manager-assigned number and an optional 1 to 4 digit PIN.
A combined total of 2000 sign-in ID numbers are available per cart.

These include 1 Set Up, 1 Service, and 1998 Supervisor and User

codes combined.
- There are also an additional 2000 codes for CS locking drawers.

General Operating Instructions

Default
Unlock Cart
Unlock CS Drawer
Change Set Up Code
Change Service Code
Add / Delete Supervisor Code
Edit Supervisor PIN / Name / Card
Add / Delete User Code
Edit User PIN / Name / Card
Add / Delete CS Code
Edit CS User PIN / Name / Card
Set Auto Lock Timer - Cart
Set Auto Lock Timer - CS Drawer
Set Cart Date & Time
Run Diagnostic Tests

311

X
X
X
X

911

X

1350

X
X
X
X
X
X
X
X

0531

X

X

X

7777

X

X

Set Up

Code

Service

Code

Super-

visor

Code

User

Code

CS

Code

continued...

1

Section 5: Set Up Code Functions

Programming Instructions

Section 4: Low Battery Indicator/Recharge Batteries

Содержание Flexline FL420

Страница 1: ...that batteries be routinely recharged once a week for 6 to 8 hours Plug the recharger into a standard 120VAC wall outlet Plug the recharger jack into the 12 long breakaway extender and the angled male end of the extender into the jack on the back of the cart The extender is important It will help to prevent drive away damage if the cart is moved while connected to the recharger While the battery i...

Страница 2: ... Code Note Edit Existing Supervisor Code Add New User Code Delete Existing User Code Edit Existing User Code Add New User Card Note Note Note Note Cannot change Supervisor Code itself but can Edit information tied to Supervisor Code i e PIN Press OK to wake up touch pad Enter Supervisor Code Press OK Press FUNCTION key several times until CHANGE THE MANAGER PIN is displayed Press OK Enter current ...

Страница 3: ... set time in seconds enter a leading 0 in front of the number e g 015 15 seconds To set time in minutes do not enter a leading 0 e g 15 15 minutes Add New Controlled Substance Code Delete Existing Controlled Substance Code Edit Existing Controlled Substance Code Set Auto Lock Timer Cart Note Note Note Note Press OK key to wake up touch pad Enter Supervisor Code and press OK Press the FUNCTION key ...

Страница 4: ...ause the cart s Servomotor is not properly calibrated see section below lock failures may also be due to jammed drawers or an improperly adjusted cart lock switch Lock the cart manually before starting this test Press OK to wake up touch pad Enter Service Code and press OK Press FUNCTION key several times until UNLOCK CART is displayed Press OK the cart will unlock Press OK to relock the cart If t...

Страница 5: ...AIN SERVO will be displayed Press SIGN OUT to exit Service Mode Press OK to wake up touch pad Enter Service Code and press OK Press FUNCTION key several times until ADJUST SERVO IDLE POSITION is displayed Used to reset the Servomotor offset idle The factory setting is typically 5 Adjust the setting from 1 to 9 as directed by the factory using the numeric keys Press SIGN OUT to exit Service Mode Pr...

Страница 6: ... to wake up the touchpad Still holding the switch enter 911 and press OK Follow prompts to erase memory Release the S2 switch Press SIGN OUT to exit Service Mode Note Note The Reset Switch allows for quick electrical recovery when the touch pad is not responding The reset switch is located on the back of the cart Before using the switch ensure that the cart is unplugged from the charger Press the ...

Отзывы: